(No.RA033<Rev.001>)1-57
21. QT
Deviation
adjust [An-
alog Wide]
FPU Test mode
1) Adjust Item: [QT Deviation (Analog
Wide)]
Connect the Deviation Meter to the TX
ANT end via the ATT.
Deviation Meter setting
LPF: 3kHz, HPF: OFF
De-emphasis: OFF
Detector: p-p/2
Press [Transmit] button.
Deviation
meter
Oscillo-
scope
Rear TX ANT
PC
ADJ
0.75kHz Devi-
ation
±0.05kHz
Press [Apply] button to
store the adjustment
value.
22. QT
Deviation
adjust [An-
alog Nar-
row]
FPU Test mode
1) Adjust Item: [QT Deviation (Analog
Narrow)]
Connect the Deviation Meter to the TX
ANT end via the ATT.
Deviation Meter setting
LPF: 3kHz, HPF: OFF
De-emphasis: OFF
Detector: p-p/2
Press [Transmit] button.
0.35kHz Devi-
ation
±0.05kHz
Press [Apply] button to
store the adjustment
value.
23. DQT
Devia- tion
adjust [An-
alog Wide]
FPU Test mode
1) Adjust Item: [DQT Deviation(Ana-
log Wide)]
Connect the Deviation Meter to the TX
ANT end via the ATT.
Deviation Meter setting
LPF: 3kHz, HPF: OFF
De-emphasis: OFF
Detector: Peak hold
Press [Transmit] button.
0.75kHz Devi-
ation
±0.05kHz
Press [Apply] button to
store the adjustment
value.
24. DQT
Deviation
adjust [An-
alog Nar-
row]
FPU Test mode
1) Adjust Item: [DQT Deviation (Ana-
log Narrow)]
Connect the Deviation Meter to the TX
ANT end via the ATT.
Deviation Meter setting
LPF: 3kHz, HPF: OFF
De-emphasis: OFF
Detector: Peak hold
Press [Transmit] button.
0.35kHz Devi-
ation
±0.05kHz
Press [Apply] button to
store the adjustment
value.
25. DTMF
Deviation
adjust [An-
alog Wide]
FPU Test mode
1) Adjust Item: [DTMF Deviation (An-
alog Wide)]
Connect the Deviation Meter to the TX
ANT end via the ATT.
Deviation Meter setting
LPF: 15kHz, HPF: OFF
De-emphasis: OFF
Detector: +peak, -peak
Press [Transmit] button.
Deviation
meter
Oscillo-
scope
Rear TX ANT
PC
ADJ
3.0kHz Devia-
tion
±0.05kHz
Press [Apply] button to
store the adjustment
value.
26. DTMF
Deviation
adjust [An-
alog Nar-
row]
FPU Test mode
1) Adjust Item: [DTMF Deviation (An-
alog Narrow)] Connect the Deviation
Meter to the TX ANT end via the ATT.
Deviation Meter setting
LPF: 15kHz, HPF: OFF
De-emphasis: OFF
Detector: +peak, -peak
Press [Transmit] button.
1.5kHz Devia-
tion
±0.05kHz
Press [Apply] button to
store the adjustment
value.
Item
Condition
Measurement
Adjustment
Specifications / Re-
marks
Test-
equipment
Unit
Terminal Unit
Parts
Method