1-42 (No.RA033<Rev.001>)
SECTION 4
ADJUSTMENT
4.1
Test Equipment Required for Alignment
* The test equipment which is not used for adjustment is contained in this table.
MIC connector (Front panel view)
Test cable for microphone input (E30-3360-28)
Test Equipment
Major Specifications
1. Standard Signal Generator
(SSG)
Frequency Range
136 to 174MHz
Modulation
Frequency modulation and external modulation
Output
0.1
μ
V to greater than 1mV
2. Power Meter
Input Impedance
50
Ω
Operation Frequency
136 to 174MHz or more
Measurement Capability
Vicinity of 100W
3. Deviation Meter
Frequency Range
136 to 174MHz
4. Digital Volt Meter (DVM)
Measuring Range
1V to 25V DC
Input Impedance
High input impedance for minimum circuit loading
5. Oscilloscope
DC through 30MHz
6. High Sensitivity
Frequency Counter
Frequency Range
10Hz to 600MHz
Frequency Stability
0.01ppm or less
7. Ammeter
15A or more
8. AF Volt Meter (AF VM)
Frequency Range
50Hz to 10kHz
Voltage Range
3mV to 3V
9. Audio Generator (AG)
Frequency Range
50Hz to 5kHz
Output
0 to 1V
10. Distortion Meter
Capability
1% or less at 1kHz
Input Level
50mV to 10Vrms
11. Voltmeter
Measuring Range
10V to 1.5V DC or less
Input Impedance
50k
Ω
/V or greater
12. Spectrum Analyzer
with Tracking Generator
Frequency Range
10MHz to 1GHz
Bandwidth
1kHz to 200MHz
Tracking Generator Output -40dBm to greater than -20dBm
13. 4
Ω
Dummy Load
Approx. 4
Ω
, 5W
8
1
1: GND
2: SB
3: GND
4: PTT
5: MIG
6: MIC
7: HOOK
8: NC
Cut
HOOK
(GRY)
MIC (WHT)
MICG (SHIELD)
to
AG
AF VM
PTT
(BLU)
GND
(BLK )
PTT SW
Plug cord
Part No. E30-3360-28
8 pin
8 pin