(No.RA033<Rev.001>)1-51
15 .Low
RSSI Ad-
just
[NXDN
Very Nar-
row]
FPU Test mode
1) Adjust Item: [Low RSSI
(NXDN Very Narrow)]
Connect the SSG to the RX
ANT.
SSG setting
Frequency: [Low], [Low’] [Cen-
ter], [High’], [High]
Output: -118dBm (0.28
μ
V)
MOD: OFF
SSG
Rear RX ANT
PC
ADJ
Press [Apply] button to store
the adjustment value.
16. High
RSSI Ad-
just [Ana-
log Wide]
FPU Test mode
1) Adjust Item: [High RSSI (Ana-
log Wide)]
Connect the SSG to the RX
ANT.
SSG setting
Frequency: [Low], [Low’] [Cen-
ter], [High’], [High]
Output: -70dBm (70.7
μ
V)
MOD: 1.0kHz
DEV: ±3.0kHz
SSG
Rear RX ANT
PC
ADJ
Press [Apply] button to store
the adjustment value.
17. High
RSSI Ad-
just [Ana-
log Nar-
row]
FPU Test mode
1) Adjust Item: [High RSSI (Ana-
log Narrow)]
Connect the SSG to the RX
ANT.
SSG setting
Frequency: [Low], [Low’] [Cen-
ter], [High’], [High]
Output: -70dBm (70.7
μ
V)
MOD: 1.0kHz
DEV: ±1.5kHz
18. High
RSSI Ad-
just
[NXDN
Very Nar-
row]
FPU Test mode
1) Adjust Item: [High RSSI
(NXDN Very Narrow)]
Connect the SSG to the RX
ANT.
SSG setting
Frequency: [Low], [Low’] [Cen-
ter], [High’], [High]
Output: -70dBm (70.7
μ
V)
MOD: OFF
Item
Condition
Measurement
Adjustment
Specifications / Remarks
Test-
equipment
Unit
Terminal Unit
Parts
Method