1-54 (No.RA033<Rev.001>)
8. High
Power
Down De-
tection ad-
just
FPU Test mode
1) Adjust Item: [RF Power Down De-
tection (High)]
Power
Meter
Rear TX ANT
PC
ADJ
12W
±0.5W
Press [Apply] button to
store the adjustment
value.
9. Mid
Power
Down De-
tection ad-
just
FPU Test mode
1) Adjust Item: [RF Power Down De-
tection (Mid)]
2.5W
±0.5W
Press [Apply] button to
store the adjustment
value.
10. Low
Power
Down De-
tection ad-
just
FPU Test mode
1) Adjust Item: [RF Power Down De-
tection (Low)]
0.25W
±0.05W
Press [Apply] button to
store the adjustment
value.
11. Maxi-
mum Devi-
ation
Adjust
[NXDN
Narrow]
FPU Test mode
1) Adjust Item: [Maximum Deviation
(NXDN Narrow)]
Power
Meter
PC
ADJ
Write the val-
ue as follow-
ings (typical
value)
[Maximum
Deviation
(NXDN Nar-
row)] = 530
Press [Apply] button to
store the adjustment
value.
12. Maxi-
mum Devi-
ation
Adjust
[NXDN
Very Nar-
row]
FPU Test mode
1) Adjust Item: [Maximum Deviation
(NXDN Very Narrow)]
Write the val-
ue as follow-
ings (typical
value)
[Maximum
Deviation
(NXDN Very
Narrow)] =
530
13. Maxi-
mum Devi-
ation
Adjust
[Analog
Wide]
FPU Test mode
1) Adjust Item: [Maximum Deviation
(Analog Wide)]
Write the val-
ue as follow-
ings (typical
value)
[Maximum
Deviation (An-
alog Wide)] =
530
14. Maxi-
mum Devi-
ation
Adjust
[Analog
Narrow]
FPU Test mode
1) Adjust Item: [Maximum Deviation
(Analog Narrow)]
Write the val-
ue as follow-
ings (typical
value)
[Maximum
Deviation (An-
alog Narrow)]
= 530
Item
Condition
Measurement
Adjustment
Specifications / Re-
marks
Test-
equipment
Unit
Terminal Unit
Parts
Method
Summary of Contents for NXR-5700
Page 121: ...MEMO ...