1-70 (No.RA032<Rev.001>)
[Analog
Wide
4k]
1) Adj item:
[As SQL]
Adjust:[***]
2) Adj item:
[700M RX/TA
Low]
→
[700M RX/TA
Center]
→
[700M RX/TA
High]
→
[800M RX/TA
Low]
→
[800M RX/TA
Ceter]
→
[800M RX/TA
High]
SSG output:
12dB SINAD level
-3dB
(MOD: 1kHz/
±2.4kHz)
1) Adj item:
[Open Squelch
(Analog Wide 4k)]
2) Adj item:
[Frequency:
700 MHz Band]
[RX/TA Low]
→
[RX/TA Center]
→
[RX/TA High]
[Frequency:
800MHz Band]
[RX/TA Low]
→
[RX/TA Ceter]
→
[RX/TA High]
SSG output:
12dB SINAD level
-3dB
(MOD: 1kHz/
±2.4kHz)
SSG
Distor-
tion
meter
Oscillo-
scope
Panel ANT
Ext.
SP
con-
nector
Panel
[Panel tuning mode]
After input signal from
SSG, press [ ] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
[Analog
Narrow]
1) Adj item:
[An SQL]
Adjust:[***]
2) Adj item:
[700M RX/TA
Low]
→
[700M RX/TA
Center]
→
[700M RX/TA
High]
→
[800M RX/TA
Low]
→
[800M RX/TA
Ceter]
→
[800M RX/TA
High]
SSG output:
12dB SINAD level
-3dB
(MOD: 1kHz/
±1.5kHz)
1) Adj item:
[Open Squelch
(Analog Narrow)]
2) Adj item:
[Frequency:
700 MHz Band]
[RX/TA Low]
→
[RX/TA Center]
→
[RX/TA High]
[Frequency:
800MHz Band]
[RX/TA Low]
→
[RX/TA Ceter]
→
[RX/TA High]
SSG output:
12dB SINAD level
-3dB
(MOD: 1kHz/
±1.5kHz)
SSG
Distor-
tion
meter
Oscillo-
scope
Panel ANT
Ext.
SP
con-
nector
Panel
[Panel tuning mode]
After input signal from
SSG, press [ ] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
Item
Condition
Measurement
Adjustment
Specifi-
cations
/Remarks
Panel tuning mode
PC test mode
Test-
equip-
ment
Unit
Ter-
minal
Unit
Parts
Method
Summary of Contents for NX-5900