(No.RA032<Rev.001>)1-57
15. P25
H-CPM
Devia-
tion
1) Adj item:
[P2 P2DEV]
Adjust:[****]
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item:
[700M RX/TA
Low]
→
[700M RX/TA
High]
→
[700M TX Low]
→
[700M TX
High]
→
[800M TX Low]
→
[800M TX
High]
→
[800M RX/TA
Low]
→
[800M RX/TA
High]
Adjust:[****]
PTT : ON
Press [ ] key to
store the adjust-
ment value.
1) Adj item:
[P25 H-CPM
Deviation]
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item:
[Frequency:
700MHz Band]
[RX/TA Low]
→
[RX/TA High]
→
[TX Low]
→
[TX High]
[Frequency:
800MHz Band]
[TX Low]
→
[TX High]
→
[RX/TA Low]
→
[RX/TA High]
Press [Transmit]
button.
Press [Apply All]
button to store the
adjustment value.
Devia-
tion
meter
Oscil-
lo-
scope
Panel ANT
Panel [Panel
tuning
mode]
[
],
[
]
[PC
test
mode]
[
←
],
[
→
]
Write fixed value for
each adjustment point.
(The value is written be-
low.) Transmit at each
adjustment point and
check that the deviation
is between 3090Hz and
3215Hz.
Deviation meter
LPF: 3kHz
HPF: OFF
[Fixed Value]
482
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press [Transmit]
button
3090~3215Hz
[PC test
mode]
Press [Apply
All] button to
store the
adjustment
value after all
adjustment
point was
adjusted.
16.
NXDN
High
Devia-
tion
[NXDN
Narrow]
1) Adj item:
[Nn NDEV]
Adjust:[****]
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item:
[700M RX/TA
Low]
→
[700M RX/TA
High]
→
[700M TX Low]
→
[700M TX
High]
→
[800M TX Low]
→
[800M TX
High]
→
[800M RX/TA
Low]
→
[800M RX/TA
High]
Adjust:[****]
PTT : ON
Press [ ] key to
store the adjust-
ment value.
1) Adj item:
[NXDN High
Deviation
(NXDN Narrow]
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item:
[Frequency:
700MHz Band]
[RX/TA Low]
→
[RX/TA High]
→
[TX Low]
→
[TX High]
[Frequency:
800MHz Band]
[TX Low]
→
[TX High]
→
[RX/TA Low]
→
[RX/TA High]
Press [Transmit]
button.
Press [Apply All]
button to store the
adjustment value.
Devia-
tion
meter
Oscil-
lo-
scope
Panel ANT
Panel [Panel
tuning
mode]
[
],
[
]
[PC
test
mode]
[
←
],
[
→
]
Write fixed value for
each adjustment point.
(The value is written be-
low.) Transmit at each
adjustment point and
check that the Analog
deviation is between
2995Hz and 3117Hz.
Deviation meter
LPF: 3kHz
HPF: OFF
[Fixed Value]
501
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press [Transmit]
button
2995~3117Hz
[PC test
mode]
Press [Apply
All] button to
store the ad-
justment val-
ue after all
adjustment
point was ad-
justed.
Item
Condition
Measurement
Adjustment
Specifica-
tions
/Remarks
Panel tuning
mode
PC test mode
Test-
equip-
ment
Unit
Ter-
minal
Unit
Parts
Method
Summary of Contents for NX-5900