NX-720
76
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations/
Remarks
Panel tuning mode
PC test mode
Test-
equipment
Unit
Terminal
Unit
Parts
Method
6. QT
Deviation *4
[Wide]
1) Adj item: [QT]
Adjust: [
.
.
.]
PTT: ON
Press [
] key to
store the adjust-
ment value.
1) Adj item: [QT
Deviation (Analog
Wide)]
Deviation meter
LPF: 3kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
Deviation
meter
Oscillo-
scope
ANT
[Panel
tuning
mode]
[
],
[
]
[PC test
mode]
[
],
[
]
Write the value
513 (Reference
value)
0.75kHz±0.05kHz
7. DQT
Deviation
*4
[Narrow]
1) Adj item: [DQT]
Adjust: [
.]
Deviation meter
LPF: 3kHz
HPF: OFF
PTT: ON
Press [
] key to
store the adjust-
ment value.
1) Adj item: [DQT
Deviation (Analog
Narrow)]
Deviation meter
LPF: 3kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
Deviation
meter
Oscillo-
scope
ANT
[Panel
tuning
mode]
[
],
[
]
[PC test
mode]
[
],
[
]
Write the value
430 (Reference
value)
0.35kHz±0.05kHz
[Wide]
1) Adj item: [DQT]
Adjust: [
.
.
.]
PTT: ON
Press
] key to
store the adjust-
ment value.
1) Adj item: [DQT
Deviation (Analog
Wide)]
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
Write the value
430 (Reference
value)
0.75kHz±0.05kHz
8. LTR
Deviation *4
[Narrow]
1) Adj item: [LTR]
Adjust: [
.]
Deviation meter
LPF: 3kHz
HPF: OFF
PTT: ON
Press [
] key to
store the adjust-
ment value.
1) Adj item: [LTR
Deviation (Analog
Narrow)]
Deviation meter
LPF: 3kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
Deviation
meter
Oscillo-
scope
ANT
[Panel
tuning
mode]
[
],
[
]
[PC test
mode]
[
],
[
]
Write the value
465 (Reference
value)
0.75kHz±0.05kHz
[Wide]
1) Adj item: [LTR]
Adjust: [
.
.
.]
PTT: ON
Press [
] key to
store the adjust-
ment value.
1) Adj item: [LTR
Deviation (Analog
Wide)]
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
Write the value
465 (Reference
value)
1.00kHz±0.05kHz
Summary of Contents for NEXEDGE NX-720