NX-720
96
Pin
No.
Pin
Name
I/O
Signal
Type
Description
Item and Condition
Min
Typ
Max
Unit
Note
11
FNC6
I/O Digital
Programmable I/O
VIH
4.0
-
5.2
V
VIL
-0.5
-
1.0
V
VOH (Io=-1.5mA)
4.0
-
5.2
V
VOL (Io=1.5mA)
-
-
1.1
V
12
50MC
O
Power
5V DC Power supply
Output Voltage
4.5
5.0
5.25
V
Output Current
-
-
100
mA
13
HR1
I
Analog Horn alert signal input
Input Voltage
5
-
16
V
Input Current
-
-
2.0
A
Rds (ON)
-
55
108
m
14
HR2
O
Analog Horn alert signal output
Output Voltage
-
-
16
V
Output Current
-
-
2.0
A
15
GND
-
GND
Ground
-
TERMINAL FUNCTION
Summary of Contents for NEXEDGE NX-720