background image

P/N:LS10248-000HW-E | REV. 

F

 | 

FEBRUARY

/

11

/202

ECN: 0002934

Honeywell Connected Life Safety Services

CLSS Gateway

HON-CGW-MBB

Installation and Users’ Manual

Summary of Contents for HON-CGW-MBB

Page 1: ...P N LS10248 000HW E REV F FEBRUARY 11 2022 ECN 0002934 Honeywell Connected Life Safety Services CLSS Gateway HON CGW MBB Installation and Users Manual ...

Page 2: ... 2 3 Software and Firmware Updates 20 3 2 4 Viruses and Other Malicious Software Agents 20 3 2 5 Network and Firewall Setup 20 Best Practices Network Security 21 Best Practices Connected Devices 21 3 2 6 Securing the Monitoring Stations 21 Section 4 Installation 22 4 1 Wall Mounting the Fixed Gateway 22 4 2 Mounting the Portable Gateway 24 4 2 1 Mounting onto the Chassis 24 4 3 Gateway Board Conne...

Page 3: ...rify the Upgrade 39 6 1 5 LED Indications During the Upgrade 39 6 2 Troubleshooting 40 6 2 1 To Troubleshoot LED Indicated Issues 40 6 2 2 To Troubleshoot Other Issues 41 Section 7 Modbus Communications 43 7 1 Operation 43 7 2 Functionality 43 7 3 Recommended Cybersecurity Practices 43 7 4 Required Software 43 7 5 IP Requirements 43 7 5 1 IP Port Settings 43 7 5 2 IP Restrictions 44 7 6 Bandwidth ...

Page 4: ... Read Device Identification 0x2B 0x0E 68 7 25 Troubleshooting 69 7 25 1 What are some basic guidelines when installing a CLSS Gateway 69 7 25 2 How fast can the Modbus client poll the gateway 69 7 25 3 How can I tell if the gateway is running 69 7 25 4 How do I recover a lost password from the gateway 69 7 25 5 What is an initialization read for analog values 69 7 25 6 How many analog values can I...

Page 5: ...patible Node Types 101 8 7 1 Direct Connect Node Type Compatibility 102 Appendix A Gateway Operating Conditions 103 A 1 Wirings and Power 103 Appendix B Modulations and Power Used 104 Appendix C Connecting to the Panels 105 C 1 Gateway Board Connections 105 C 1 1 Connecting to a Fire Alarm Panel 106 Improving the Signal Fidelity 106 C 2 Supported Panels 107 C 3 AM Series Panels 107 C 3 1 Connectio...

Page 6: ...UL 137 C 10 1 Connection Options 137 C 10 2 To Use a NUP Connection 137 C 11 NOTIFIER European Panels EN 141 C 11 1 Connection Options 141 C 11 2 Preparing for Connections 141 C 11 3 To Use a NUP Connection 141 C 12 Silent Knight Panels 143 C 12 1 Connection Options 143 C 12 2 To Use an RS 485 Connection 143 C 12 3 Programming for Annunciator ANN PRI 145 C 12 4 To Program for Annunciator 145 C 13 ...

Page 7: ...l offers suitable information sources based on informational requirements 1 2 1 Training Modules Training modules are available when logged onto https fire us honeywell com help videos For USA https fire eu honeywell com help videos For Europe 1 2 2 Related Documents The table below lists documents related with the CLSS Gateway Table 1 1 Related Documents List Product Type Honeywell Connected Life...

Page 8: ...al 52747 NFS2 640 Panel Install the NFS2 640 panel NFS2 640 Installation Manual 52741LD Customize the NFS2 640 panel NFS2 640 Programming Manual 52742 Operate the NFS2 640 panel NFS2 640 Operations Manual 52743 NFS2 3030 Panel Operate the NFS2 3030 panel NFS2 3030 Operations Manual LS10006 051NF E N16 Panel Operate the N16 panel N16 Operations Manual LS10239 051NF E Product Type VeriFire Tool For ...

Page 9: ...o Install and wire the CLSS Pathway inside an enclosure CLSS Pathway Product Installation Document P N LS10338 000HW E Quickly install and configure for the central station communication CLSS Pathway Quick Start Guide P N LS10339 000HW E Use various installation and configuration options CLSS Pathway Installation and Operation Manual This document P N LS10340 000HW E Product Type CLSS Connector Ut...

Page 10: ... Figure 2 1 The OC Code label added Table 2 1 Label Name column and the OC code details added 2 5 Security Recommendations Added this section Figure 3 4 Eth1 and Eth0 identified 4 4 Honeywell CLSS Alarm Transmission Services Updated for NOC Appendix C Removed the Fire Lite connection procedure Appendix C Updated the FireWarden connection section with firmware details and additional notes Figure C ...

Page 11: ...onnecting to a Fire Alarm Panel The Improving the Signal Fidelity section newly added C 4 ESSER Panels Updated for new changes C 5 FireWarden Panels Updated for new changes C 6 Gamewell FCI Panels Updated for new changes C 11 Triga Panels Added this new section C 12 VESDA Detectors Added this new section February 07 2022 5 4 3 Path Selection Dual Path selection details are added Section 8 The BACn...

Page 12: ...IER Intelligent Fire Alarm Control Panels NUP NOTIFIER Universal Protocol The Universal Protocol by NOTIFIER for all fire alarm panel communications This protocol enables direct transfer of data between the panels and networks without the need to translate OC Ownership Code The code that confirms ownership of the gateway POTS Plain Old Telephone Services TTL Transistor Transistor Logic A physical ...

Page 13: ...rference including interference that may cause undesired operation of the device Déclarations de conformité Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radioélectr...

Page 14: ...AMILIAR WITH THE RELEVANT REGULATIONS CAUTION USERS MUST FOLLOW THE PROCESSES AND USAGES APPROVED AS PER THE REGULATORY COMPLIANCE A CHANGED OR MODIFIED USAGE NOT EXPRESSLY APPROVED BY COMPLIANCE COULD VOID THE USER S AUTHORITY TO OPERATE THE CLSS Gateway ELECTRO STATIC SENSITIVE DEVICES TAKE SUITABLE ESD PRECAUTIONS WHEN REMOVING OR INSTALLING PRINTED CIRCUIT BOARDS THIS GATEWAY S PANEL IS CE MAR...

Page 15: ...onnection with the fire alarm panel enables reading the inventory and transmitting the data Connection with the CLSS Site Manager facilitates remotely monitoring and managing the fire detection systems 2 2 Honeywell Connected Life Safety Services The software suite enables remote management of fire detection systems It monitors the building s fire system events in real time and notifies users abou...

Page 16: ... configuration computer Cable CAT 5 standard Ethernet cable with RJ45 connector 3 RS 485B P5 Receives the alarm data and device data from an RS 485 port of a panel 4 RS 485A P1 Receives the alarm data and device data from an RS 485 port of a panel 5 UART TTL P4 Receives the alarm data and device data from a UART TTL port of a panel 6 NUP RS 232 P7 Transfers fire related and device related data fro...

Page 17: ...Power LED Indicates the power supply status for cellular communications ON The LTE radio device is receiving power from the circuit board OFF The LTE radio device is not receiving power DL2 Trouble LED Indicates the gateway s operational status OFF There are no issues FLASHING SLOW flashes once per 1 second There are communication issues with the panel or the Internet connectivity ON There is a cr...

Page 18: ...Manager FLASHING SLOW flashes once per 1 second The gateway is connected with CLSS Site Manager FLASHING FAST flashes once per 0 2 second The gateway is connected with Internet but not connected with the CLSS Site Manager OFF The gateway is not connected with Internet DL5 Wireless Connectivity LED Indicates the gateway wireless connectivity status FLASHING SLOW flashes once per 1 second The wirele...

Page 19: ...board receives power through its NUP RS 232 port NUP_OUT The gateway board receives power through its power supply port which is connected to an external power supply source S8 For enabling mobile pairing Pressing the switch for ten seconds enables mobile pairing Tamper Switches Purpose Tamper 1 For alerting whenever the gateway enclosure door is opened It is located at the front side of the gatew...

Page 20: ...bility to the installation Site and Honeywell User Access and Passwords Observe the following good practices The password has one numerical one upper case one lower case and one special character whenever any user registers or changes the credentials Enforce a password change periodically Do now allow any dictionary words as passwords Check passwords against known common weak password databases Do...

Page 21: ...ort another computer uses to access a gateway functionality An application on the gateway will be actively listening on this port for client connections Outbound Out Port The gateway uses outbound ports to connect to Internet or CLSS Site Manager The Cloud services in the CLSS Site Manager will be listening on these ports waiting for a connection from the gateway By default block all inbound and o...

Page 22: ... Stations Good security practices should be observed on the Monitoring Station PCs Operating systems and software should be kept up to date by installing the manufacturers updates as well as maintaining up to date anti virus software on all computers which may be connected directly or via a network For monitoring stations it is recommended to use secure VPN channel which must be placed behind the ...

Page 23: ...e 4 1 Figure 4 1 Screw Hole Knock Out 5 Depending upon the wall construction select suitable screws to mount the enclosure 6 Place the backbox on the wall where the enclosure is to be mounted 7 Confirm that the placement of the backbox allows the door to swing open freely NOTE This section refers to the fixed gateway P N HON CGW MBB For instructions on mounting the portable gateway P N CGW MB refe...

Page 24: ...g the Backbox 9 Remove the backbox 10 In the top mounting hole insert the mounting screw 11 Tighten the screw leaving space for hanging the enclosure 12 Mount the backbox over the top screw and level it 13 Mark the locations for the two lower mounting holes 14 Remove the backbox and drill the mounting holes 15 Mount the backbox over the top screw then install the remaining fasteners 16 Tighten all...

Page 25: ...anual P N LS10248 000HW E REV F FEB 11 2022 24 Mounting the Portable Gateway Installation 4 2 Mounting the Portable Gateway Section reserved for future functionality 4 2 1 Mounting onto the Chassis Section reserved for future functionality ...

Page 26: ...d an external power supply Figure 4 3 illustrates the connection options at the top side of the gateway board Figure 4 3 Gateway Connections Top Side Figure 4 4 illustrates the gateway connection options at the bottom side of the gateway board Figure 4 4 Gateway Connection Options Bottom Side Fire Alarm Panel CLSS Cloud Modbus Client Configuration Computer Mobile Connection NUP Ethernet Connection ...

Page 27: ... not mount the gateway on or near metal objects This includes steel cabinets metal walls steel beams steel roofs or roofing girders foil backed insulated walls and duct works During the installation periodically monitor the signal quality via the CLSS App to predict QoS Quality of Service of the LTE radio over time If the installation location does not offer good QoS try the following options 1 Mo...

Page 28: ...dule comes with a factory mounted SIM card If necessary replace it as follows 1 Open the gateway door 2 Remove the NUP cable or the 24v DC power cable to switch OFF the gateway board 3 Remove the retention strap screw and the retention strap see Figure 4 6 4 Slide the cellular module upward to disconnect it from the gateway board 5 Carefully remove the back cover of the cellular module WARNING DO ...

Page 29: ...n installing an aerial ensure that The aerial is within its granted FCC directional gain limitations The installation is in accordance with the manufacturer s instructions To Install an External Antenna 1 Switch the SW1 switch on the cellular module to EXT 2 Connect the internal coax adapter onto the module 3 Route the coax adapter cable through the knock out on the enclosure 4 Tighten the nuts at...

Page 30: ...rt the Topology Data 1 Using the tool which the panel manufacturer recommends export the panel s topology data into your configuration computer 2 From the configuration computer log into the Connected Life Safety Services application 3 Ensure that the relevant customer site and building details are available in the application 4 Select the building where the panel is located 5 Go to the building s...

Page 31: ...r the App to connect with the gateway the fire alarm panel Internet and CLSS Site Manager The App notifies you when configuration is completed 9 On the dashboard from the All Customers option find the required customer site 10 Tap on the specific building 11 To commission the gateway tap on CONNECT GATEWAY and follow the on screen instructions see Figure 5 2 NOTE Based on the gateway you are confi...

Page 32: ...nnected Life Safety Services App the option to enable the control functionality is available for 60 minutes which can be extended At the end of 60 minutes the user will have the option to extend the session If not extended the session will expire after 60 minutes and the user must enable a new session of control functionality within the Connected Life Safety Services App ...

Page 33: ...cating LED ON Successful power connection DL1 ON OFF ON The cellular module is installed and receiving power OFF The cellular module is not installed DL2 OFF There are no issues DL6 Flashing fasta a FLASHING FAST 0 2 second ON and 0 2 second OFF Successful mobile connection Flashing slowb b FLASHING SLOW 1 second ON and 1 second OFF Ready for connection OFF Disabled mobile connection DL3 ON The ga...

Page 34: ...y 3 Select the Customer and the Site 4 Tap on your connected gateway from the list of gateways 2 Tap on the Panel Brand Connection option on the Gateway Summary screen 3 Tap on Panel Brand 4 Change the panel brand if required 5 Tap NEXT 6 Select the connection type for the panel from the Connection Type screen 7 Tap APPLY 8 Tap Panel Type on the Gateway Summary screen 9 Change the values for the p...

Page 35: ...LSS Site Manager the service provider administrator should activate the central station communication It is a one time activity which can be done for an operational gateway or for a newly installed gateway Adding a Central Station to the CLSS Account Only those central stations added in the external accounts of the CLSS Site Manager can receive alarms the gateway sends Therefore a service provider...

Page 36: ...a service provider administrator can configure the central station communication of the CLSS Gateway 1 Log onto the CLSS Site Manager 2 Select the customer from the All Customers list at the top left side 3 Select the customer select the site and then select the building requiring alarm transmission 4 Click the FEATURE ACTIVATION icon at the left navigation bar 5 Select Installed Gateways and then...

Page 37: ...Communication for Alarm Transmission While configuring the central station communication you can choose a single path or two paths for alarm transmissions Reporting options are LTE cellular only IP only IP Primary with LTE cellular backup or LTE Cellular Primary with IP backup Supervision Period Dual paths are monitored for integrity at an interval period as per NFPA 72 requirements In case of a f...

Page 38: ...upgrade happens in the background while the system is running After the upgrade the gateway will reboot 6 1 1 To Upgrade Before Commissioning the Gateway 1 Connect the gateway to Internet 2 Log onto the CLSS Site Manager 3 Click VIEW on the notification at the top Or Click the SETTINGS icon at the bottom left 4 Click Gateway Management in the Settings page 5 Click Add Gateway on top CAUTION BEFORE...

Page 39: ...y in the Search OC field to find the gateway to update Or Scroll across to find the gateways to update 9 Click Update 6 1 2 To Upgrade After Commissioning the Gateway 1 Log onto the CLSS Site Manager 2 Click VIEW on the notification at the top Or Click the SETTINGS icon at the bottom left 3 Click Gateway Management in the Settings page 4 Enter the OC of the gateway in the Search OC field to find t...

Page 40: ...nter the following IP address for the configuration tool https 192 168 10 190 9443 config index html 6 In the Sign In page enter the password 7 In the list of settings options click Diagnostic 8 In the GATEWAY FIRMWARE UPGRADE section click Choose File 9 Select the firmware image file and click Choose 10 Once the chosen file is uploaded click Upgrade 6 1 4 To Verify the Upgrade 1 After the restart...

Page 41: ...s getting its 24V DC power If the above steps do not fix the issue contact Honeywell Technical Support DL2 Trouble LED Indicated Issues Trouble LED Status Other LEDs Status Possible Fixes ON and SOLID Amber Any It is a critical issue Contact Honeywell Technical Support Flashing Amber once per second DL3 The panel LED is OFF DL4 The CLSS Site Manager LED is flashing once per second Check the follow...

Page 42: ...l LED is flashing once per second DL4 The CLSS Site Manager LED is OFF Ensure that the WLAN settings in the gateway configuration tool are correct Ensure that the building s IP network has Internet and CLSS Site Manager connectivity DL6 Mobile LED Indicated Issues Mobile LED Status Other LEDs Status Possible Fixes OFF DL3 The panel LED is flashing once per second DL4 The CLSS Site Manager LED is O...

Page 43: ...teway name 6 Click on the reset password icon at the right side of the gateway name 7 To confirm the reset click CONTINUE on the message displayed 8 Wait for the confirmation message 9 Log in using the default password Welcome123 There is a need to reset the gateway board to its factory default settings An unusual situation requires reverting to factory default settings Contact the Honeywell Tech ...

Page 44: ...2 Modbus clients or masters 7 3 Recommended Cybersecurity Practices Follow the highly recommended cybersecurity practices specified in the Cybersecurity Manual LS10217 000NF E Ensure that all the network security best practices discussed in Section 3 Security Recommendations are followed 7 4 Required Software ChromeTM JavaTM version 6 or above 7 5 IP Requirements 7 5 1 IP Port Settings The followi...

Page 45: ...st and response pair creates network traffic of 329 Bytes per second 329 x 1 In other words a request and response pair creates network traffic of 2632 bits per second 329 x 8 Therefore the network must be able to accommodate at least 0 0027 Mbps data flow Once every five seconds an analog request adds a small amount of network traffic Formula for CLSS Gateway network bandwidth requirement based o...

Page 46: ...ual P N LS10248 000HW E REV F FEB 11 2022 45 System Architecture Modbus Communications 7 7 System Architecture An Internet or Intranet IP network connection is needed for the architectures described here Figure 7 1 Single Panel Architecture ...

Page 47: ...CLSS Gateway Installation and Users Manual P N LS10248 000HW E REV F FEB 11 2022 46 System Architecture Modbus Communications Figure 7 2 NFN Network Architecture ...

Page 48: ...022 47 System Architecture Modbus Communications 7 7 1 Redundancy A redundant gateway is a second gateway which communicates with a Modbus client Figure 7 3 Redundant CLSS Gateways CAUTION THE FIRST AND SECOND GATEWAYS MUST HAVE DIFFERENT NODE NUMBERS AND DIFFERENT IP ADDRESSES ...

Page 49: ...e type details for the CLSS Gateway refer to the 7 31 Device Types section System Troubles There are new troubles in the CLSS Gateway and some of the system trouble names are different Example 1 New Troubles In the CLSS Gateway 460016 12th bit is Workstation Failure Example 2 Different trouble name In the Modbus Gateway The General PS Fault and the Power Supply Trouble are two different events In ...

Page 50: ... Laboratories UL 864 Control Units for Fire Alarm Systems Tenth Edition Underwriters Laboratories Canada CAN ULC S527 19 Standard for Control Units for Fire Alarm Systems Fourth Edition Installation This product is intended to be installed in accordance with the following Local AHJ Authority Having Jurisdiction National Fire Protection Association NFPA 70 National Electrical Code NFPA 72 National ...

Page 51: ... Fire Panels NFS 320 NFS 640 NFS2 640 NFS 3030 NFS2 3030 AFP2800 AFP 3030 XLS 120 XLS 140 2 XLS 2000 XLS 3000 N16 INSPIRE Network Cards NCM W NCM F HS NCM W HS NCM SF HS NCM MF HS NCM WSF HS NCM WMF HS NCM MFSF NFN GW PC NHW 2 HS NCM WMF 2 HS NCM WSF 2 HS NCM W 2 Other Products Unmonitored but network compatible DVC NCA 2 NCD NWS 3 BACNET GW 3 NFN GW PC HNW 2 NFN GW EM 3 PC NFN Gateways NFN GW PC ...

Page 52: ...ture in CLSS App 7 13 1 To Purchase the Modbus Support 1 Log onto CLSS Site Manager 2 Click on your account name and select Manage Access Figure 7 4 Selecting Manage Access 3 Click Features on the Manage Access page 4 Click Gateway under the Features section 5 Note down the purchased number under Available Features 6 Click PURCHASE at the top right side Figure 7 5 Purchasing the Modbus Support NOT...

Page 53: ...lete and refresh the page if required 12 Verify that the purchased number under Available Features is correct 7 13 2 To Activate the Modbus Support 1 Tap Perform Feature Activation on the CLSS App s welcome message Figure 7 6 Feature Activation The First Step 2 Tap Fixed Gateways 3 Select the site of the gateway 4 Find and tap the OC of the gateway 5 Tap ADD ACTIVATION 6 Tap Modbus Support under t...

Page 54: ...er used to configure the CLSS Gateway must establish an IP connection to the gateway Consult with a network administrator if unsure how to make this connection Connecting more than one CLSS Gateway prior to reconfiguring the IP address will result in an IP address conflict 7 16 To Connect with the Modbus Client 1 At the CLSS Gateway side connect an Ethernet cable to the Ethernet Port 1 2 At the Mo...

Page 55: ...0 port of the gateway 5 In the Chrome browser enter the following URL https 192 168 10 190 9443 config index html 6 Do the following if any security warning is shown Otherwise go to step 7 1 Click the Advanced link below the error message 2 Agree to proceed 7 In the Gateway Configuration Tool page enter the password 8 Go to the Network Settings in the Gateway Settings section 9 Assign the Eth1 por...

Page 56: ... NFN network except for gateways web servers and DVCs is automatically assigned a Modbus Unit ID When a new unit ID number for a node is entered the old unit ID number is reassigned to whichevernode previously used the new unit ID number However the CLSS Gateway configuration web page does accept a new unit ID number that is currently being used by a monitored node In order to reassign a unit ID n...

Page 57: ...Notes The Unknown nodes can only be seen in the Show All Nodes mode If an Unknown node comes on line and is found to be of the wrong type for the CLSS Gateway to monitor its Monitored field is automatically set to No Some nodes in the node list are not usable by the CLSS Gateway and therefore are not configurable and do not have a unit ID Monitoring Select Yes to monitor the node Select No if the ...

Page 58: ...rates similarly to a Modbus bridge Each CLSS Gateway can support up to ten panels on an NFN network Each fire panel being addressed by the Modbus master on the NFN network is identified by the Unit ID The Unit ID used in the CLSS Gateway must be in the range 1 to 240 This is a Modbus range limitation The Unit ID should match the node number of the NFN node that is being addressed For example a Uni...

Page 59: ...trol functionality 7 Read the UL Void message shown if it is enabled 8 Click Save 9 Wait until the CLSS Gateway shows the changes 10 Check that the changes are correct 7 20 3 Sending Commands Send commands through the CLSS gateway by writing command values to the appropriate holding registers For detailed register mapping information refer to the 7 22 Register Mapping section The following tables ...

Page 60: ...uiring analog values for these points at 5 second intervals Points are only polled on the NFN if the 4 20 mA module is in at least the first level of alarm status If the point is normal then the gateway returns a value of zero Activate and Deactivate work only for output controlled modules like control and relay Different panels support different zone types Refer to Table 7 8 Zone Command Availabi...

Page 61: ...tinues to poll these devices as long as the client continues to send analog value requests for points L1M1 through L1M10 at a rate faster than the Analog Value Time Out Use Case 2 A client requests analog values from the points L1M1 through L1M10 After 10 minutes of polling on a 10 second interval the client stops requesting analog values for these points Result The CLSS Gateway sends back zeros i...

Page 62: ...s for L1M1 through L1M10 and then send a request for L1M11 through L1M15 Note that the first request for analog values from a valid range of points is considered an initialization request which returns zeros 7 22 Register Mapping 7 22 1 Register Mapping Overview The CLSS Gateway uses 16 bit registers One Modbus Input register and one Modbus Holding Register are allocated for each device address Th...

Page 63: ... point other than fire alarm are acknowledged Not applicable for zones Prealarm Bit 14 The point is in a prealarm state Not applicable for zones Trouble Bit 13 The point is in a trouble state Not applicable forzones InActive Bit 12 The point is not active Active Bit 11 The point is active and there will be an active event type in the lower byte Enable Bit 10 The point is enabled Disable Bit 9 The ...

Page 64: ...ng all bits in the byte will contain a value of 1 or FFFFH Table 7 11 Point Device Type Input Register Bit Definitions Upper Byte Lower Byte Bit No 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Device Types see 7 31 Device Types Table 7 12 Input Register Addresses of the Point Device Types Start Address End Address Address 300001 300300 L1D1 L1D300 300301 300600 L1M1 L1M300 300601 300900 L2D1 L2D300 30090...

Page 65: ...cuits contained in these addresses are detailed in Table 7 15 Panel Circuits Table 7 13 Zones Panel Circuits Holding Register Bit Definitions Upper Byte Lower Byte Bit No 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Ack Block Prealarm Trouble InActive Active Enable Disable Ack Fire Alarm Active Event Type When Bit 11 is set to 1 see 7 30 CLSS Gateway Active Event Code When individual upper byte ...

Page 66: ...it 11 is a 1 See CLSS Gateway ActiveEventCode onpage 74 for detailed information about the active bell circuit The lower byte will be all 0 s if the bell circuit is not in an active state Specifically the lower byte contains the actual active event for this bell circuit An active state is defined in this gateway as any Fire Security Critical Process Medical Mass Notification or Supervisory alarm s...

Page 67: ...s on this bell circuit other than fire alarm are acknowledged Prealarm Bit 14 The bell circuit is in a prealarm state Trouble Bit 13 The bell circuit is in a trouble state InActive Bit 12 The bell circuit is not active Active Bit 11 The bell circuit is active and there will be an active event type in the lower byte Enable Bit 10 The bell circuit is enabled Disable Bit 9 The bell circuit isdisabled...

Page 68: ...nel troubles and one register is assigned as an overall panel trouble indicator as shown in Table 7 24 Panel and System Troubles Holding Register Addresses A single bit is reserved for each trouble in the system The assignment of bits to trouble codes is shown in Table 7 33 System Troubles Register Map Upper Byte Lower Byte Bit No 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Not Used Silence Res...

Page 69: ...nit ID only All other nodes reject reads in this address range Table 7 25 Gateway Information Input Register Addresses Start Address End Address Description 360001 360100 Information Debug information 320001 320015 Node Status 1 On Line 0 Off Line The CLSS Gateway tracks status of network nodes under Modbus feature monitoring 360016 360016 Gateway major version number 360017 360017 Gateway minor v...

Page 70: ...quests If only a partial response form the gateway is seen in the Modbus client try increasing the response time out value in the client to a larger value If the value is set to 5 seconds or more this should be adequate The exact response time out will depend on IP network delays and routing On a small IP network the gateway responds to a read of 100 register in less than 1 second The gateway also...

Page 71: ... gateway does not actually take an analog value reading unless the module has reached the first threshold and therefore it will return a zero reading If the client polls the gateway too quickly after the initialization poll then the gateway may still returnzeros If the client polls the analog values slower than the Analog Poll Time Out then the gateway may return allzeros 7 26 What is the Analog V...

Page 72: ...uter 2 Run the MGate Manager installation software MGM_SETUP_VERX X_BUILD_XXXXXXXX EXE found on the Software CD shipped with the MGate MB3180 3 Wait for the installation to complete 4 Run MGate Manager 5 Power up the MB3180 6 Ensure that the Ready and Ethernet lights are ON 7 Configure the MB3180 for the network 8 Wait for the configuration to complete 9 Click OK 10 Click Exit CAUTION ENSURE THAT ...

Page 73: ...r to the Serial port RS 232 RS 485 or RS 422 of MB3180 2 Connect the MB3180 to the CLSS Gateway Figures 7 8 and 7 9 show possible configurations for connecting the CLSS Gateway to the Moxa interface 3 Power up the system Figure 7 8 Connection Through Crossover Ethernet Cable Figure 7 9 Connection Through a Router NOTE The configuration used must have the approval of the AHJ Authority Having Jurisd...

Page 74: ...col Identifier in Modbus should always be 0 Function code sent by the client is not supported by the CLSS Gateway or the FACP A Control command was sent to the gateway Contact customer service Illegal function 0x02 Register address range specified by the client is not supported by the FACP Register address range requested is valid but the device e g Detector Module Zone etc is not present in the s...

Page 75: ...riority 25H Supervisory Signal Guard s Tour 30H Supervisory Signal Equipment 40H Mass Notification Supervisory Low Priority 45H Disabled Alarm AFP2800 Panel Only 52H Disabled Active AFP2800 Panel Only 55H Non Fire Activation 71H Non Fire Activation no acknowledgment required 72H CO Alarm Fire Alarm EAH CO Supervisory EBH CO Supervisory Photo Supervisory ECH CO Supervisory Fire Alarm EDH CO Alarm P...

Page 76: ...g 0200H Smoke Acclimate 0601H Smoke Ion Tracking 0201H Wireless Smoke Multi 0610H Duct Smoke Ion Latching 0202H Wireless Smoke Acclimate 0611H Duct Smoke Ion Tracking 0203H CO Alarm 0700H Smoke Photo Latching 0300H Fire CO 0701H Smoke Photo Tracking 0301H Photo CO 0702H Duct Smoke Photo Latching 0302H CO Photo Thermal IR 0703H Duct Smoke Photo Tracking 0303H Aspiration 0801H Smoke Photo Flame 0304...

Page 77: ...ment Monitor 0035H Isolated Notification Appliance Circuit 1017H Hold Up 0036H Releasing Circuit 1020H Wireless Hold Up 0037H Releasing Circuit ULC 1021H Tamper 0038H Releasing Form C 1022H Wireless Tamper 0039H Releasing Bell 1023H Secure Access 003AH Releasing Audible 1024H Telephone Page 0040H Instant Release 1030H Weather 0055H Alarms Pending 1031H Wireless Weather 0056H Control Notification A...

Page 78: ...EL DOOR OPEN 5 CORRUPT LOGIC EQUAT 13 AUXILIARY TROUBLE 6 LCD80 SUPERVISORY 14 TERM SUPERVISORY 7 EPROM ERROR FLASH IMAGE ERROR 15 ANNUN 1 TROUBLE 460002 0 ANNUN 1 NO ANSWER 8 ANNUN 5 NO ANSWER 1 ANNUN 2 TROUBLE 9 ANNUN 6 TROUBLE 2 ANNUN 2 NO ANSWER 10 ANNUN 6 NO ANSWER 3 ANNUN 3 TROUBLE 11 ANNUN 7 TROUBLE 4 ANNUN 3 NO ANSWER 12 ANNUN 7 NO ANSWER 5 ANNUN 4 TROUBLE 13 ANNUN 8 TROUBLE 6 ANNUN 4 NO A...

Page 79: ...UN 27 TROUBLE 11 ANNUN 31 TROUBLE 4 ANNUN 27 NO ANSWER 12 ANNUN 31 NO ANSWER 5 ANNUN 28 TROUBLE 13 ANNUN 32 TROUBLE 6 ANNUN 28 NO ANSWER 14 ANNUN 32 NO ANSWER 7 ANNUN 29 TROUBLE 15 NETWORK FAIL PORT A 460006 0 NETWORK FAIL PORT B 8 UDACT TROUBLE 1 NETWORK FAILURE 9 UDACT NO ANSWER 2 ADV WALK TEST 10 PROG MODE ACTIVATED 3 CHARGER FAIL 11 LOADING NO SERVICE 4 GROUND FAULT LOOP 2 12 BASIC WALK TEST 5...

Page 80: ...2 ANNUN 47 TROUBLE 5 ANNUN 43 NO ANSWER 13 ANNUN 47 NO ANSWER 6 ANNUN 44 TROUBLE 14 ANNUN 48 TROUBLE 7 ANNUN 44 NO ANSWER 15 ANNUN 48 NO ANSWER 460010 0 ANNUN 49 TROUBLE 8 ANNUN 53 TROUBLE 1 ANNUN 49 NO ANSWER 9 ANNUN 53 NO ANSWER 2 ANNUN 50 TROUBLE 10 ANNUN 54 TROUBLE 3 ANNUN 50 NO ANSWER 11 ANNUN 54 NO ANSWER 4 ANNUN 51 TROUBLE 12 ANNUN 55 TROUBLE 5 ANNUN 51 NO ANSWER 13 ANNUN 55 NO ANSWER 6 ANN...

Page 81: ...DE ENTERED 10 STYLE 4 SHORT A LOOP 4 3 NCM COMM LOSS 11 STYLE 4 SHORT B LOOP 4 4 STYLE 4 SHORT A LOOP 1 12 STYLE 4 SHORT A LOOP 5 5 STYLE 4 SHORT B LOOP 1 13 STYLE 4 SHORT B LOOP 5 6 STYLE 4 SHORT A LOOP 2 14 STYLE 4 SHORT A LOOP 6 7 STYLE 4 SHORT B LOOP 2 15 STYLE 4 SHORT B LOOP 6 460015 0 STYLE 4 SHORT A LOOP 7 8 GENERAL PS FAULT POWER SUPPLY TROUBLE 1 STYLE 4 SHORT B LOOP 7 9 STYLE 6 SHORT LOOP...

Page 82: ...ANNUN 85 TROUBLE 1 ANNUN 81 NO ANSWER 9 ANNUN 85 NO ANSWER 2 ANNUN 82 TROUBLE 10 ANNUN 86 TROUBLE 3 ANNUN 82 NO ANSWER 11 ANNUN 86 NO ANSWER 4 ANNUN 83 TROUBLE 12 ANNUN 87 TROUBLE 5 ANNUN 83 NO ANSWER 13 ANNUN 87 NO ANSWER 6 ANNUN 84 TROUBLE 14 ANNUN 88 TROUBLE 7 ANNUN 84 NO ANSWER 15 ANNUN 88 NO ANSWER 460020 0 ANNUN 89 TROUBLE 8 ANNUN 93 TROUBLE 1 ANNUN 89 NO ANSWER 9 ANNUN 93 NO ANSWER 2 ANNUN ...

Page 83: ...WER 11 ANNUN 126 NO ANSWER 4 ANNUN 123 TROUBLE 12 ANNUN 127 TROUBLE 5 ANNUN 123 NO ANSWER 13 ANNUN 127 NO ANSWER 6 ANNUN 124 TROUBLE 14 ANNUN 128 TROUBLE 7 ANNUN 124 NO ANSWER 15 ANNUN 128 NO ANSWER 460025 0 REMOTE DISPLAY 1 TROUBLE 8 REMOTE DISPLAY 5 TROUBLE 1 REMOTE DISPLAY 1 NO ANSWER 9 REMOTE DISPLAY 5 NO ANSWER 2 REMOTE DISPLAY 2 TROUBLE 10 REMOTE DISPLAY 6 TROUBLE 3 REMOTE DISPLAY 2 NO ANSWE...

Page 84: ...LE 1 REMOTE DISPLAY 25 NO ANSWER 9 REMOTE DISPLAY 29 NO ANSWER 2 REMOTE DISPLAY 26 TROUBLE 10 REMOTE DISPLAY 30 TROUBLE 3 REMOTE DISPLAY 26 NO ANSWER 11 REMOTE DISPLAY 30 NO ANSWER 4 REMOTE DISPLAY 27 TROUBLE 12 REMOTE DISPLAY 31 TROUBLE 5 REMOTE DISPLAY 27 NO ANSWER 13 REMOTE DISPLAY 31 NO ANSWER 6 REMOTE DISPLAY 28 TROUBLE 14 REMOTE DISPLAY 32 TROUBLE 7 REMOTE DISPLAY 28 NO ANSWER 15 REMOTE DISP...

Page 85: ...CONTINUITY TEST FAIL LOOP 2 9 LOOP CONTINUITY TEST FAIL LOOP 10 2 LOOP CONTINUITY TEST FAIL LOOP 3 10 UNPROGRAMMED DEVICE ON LOOP 1 3 LOOP CONTINUITY TEST FAIL LOOP 4 11 UNPROGRAMMED DEVICE ON LOOP 2 4 LOOP CONTINUITY TEST FAIL LOOP 5 12 UNPROGRAMMED DEVICE ON LOOP 3 5 LOOP CONTINUITY TEST FAIL LOOP 6 13 UNPROGRAMMED DEVICE ON LOOP 4 6 LOOP CONTINUITY TEST FAIL LOOP 7 14 UNPROGRAMMED DEVICE ON LOO...

Page 86: ...OOP 10 15 TOO MANY DEVICES ON LOOP 8 460036 0 TOO MANY DEVICES ON LOOP 9 8 MISMATCHED LOOP TYPE ON LOOP 7 1 TOO MANY DEVICES ON LOOP 10 9 MISMATCHED LOOP TYPE ON LOOP 8 2 MISMATCHED LOOP TYPE ON LOOP 1 10 MISMATCHED LOOP TYPE ON LOOP 9 3 MISMATCHED LOOP TYPE ON LOOP 2 11 MISMATCHED LOOP TYPE ON LOOP 10 4 MISMATCHED LOOP TYPE ON LOOP 3 12 Ground Fault Port A 5 MISMATCHED LOOP TYPE ON LOOP 4 13 Grou...

Page 87: ...ACKUP AMP 4 TROUBLE 460040 0 DSBUS 1 COMMFAIL 8 PRIMARY AMP 2 LIMIT 1 DSBUS 2 COMMFAIL 9 PRIMARY AMP 3 LIMIT 2 DSBUS 3 COMMFAIL 10 PRIMARY AMP 4 LIMIT 3 DSBUS 4 COMMFAIL 11 BACKUP AMP 1 LIMIT 4 AA TROUBLE BUS FAIL 12 BACKUP AMP 2 LIMIT 5 NFN PAGING CHANNEL LIMIT EXCEEDED 13 BACKUP AMP 3 LIMIT 6 BACKUP AMP LIMIT 14 BACKUP AMP 4 LIMIT 7 PRIMARY AMP 1 LIMIT 15 PRIMARY AMP 1 OVERCURRENT 460041 0 PRIMA...

Page 88: ...MISMATCH 2 ANNUN 19 TYPE MISMATCH 10 ANNUN 27 TYPE MISMATCH 3 ANNUN 20 TYPE MISMATCH 11 ANNUN 28 TYPE MISMATCH 4 ANNUN 21 TYPE MISMATCH 12 ANNUN 29 TYPE MISMATCH 5 ANNUN 22 TYPE MISMATCH 13 ANNUN 30 TYPE MISMATCH 6 ANNUN 23 TYPE MISMATCH 14 ANNUN 31 TYPE MISMATCH 7 ANNUN 24 TYPE MISMATCH 15 ANNUN 32 TYPE MISMATCH 460046 0 DISPLAY COMM LOSS 8 LOOP CARD 1 COMM LOSS 1 ALARM DEVICES DISABLED 9 LOOP CA...

Page 89: ...12 AIO Address 9 Comm Loss LSB is 0 for router 1 15 for peripheral 5 AIO Address 2 Comm Loss LSB is 0 for router 1 15 for peripheral 13 AIO Address 10 Comm Loss LSB is 0 for router 1 15 for peripheral 6 AIO Address 3 Comm Loss LSB is 0 for router 1 15 for peripheral 14 Reserved 7 AIO Address 4 Comm Loss LSB is 0 for router 1 15 for peripheral 15 Reserved 460049 0 POTS Card No Answer Missing 8 Ethe...

Page 90: ...lients may make requests to read properties of the BACnet objects Those properties are the values of the device status and programming The user subscribes to Event Notification objects per FACP and the BACnet device receives events from objects on the FACP as a result of this subscription Large networks can use multiple gateways greater than 15 panels 15 000 objects The BACnet client workstation f...

Page 91: ...lar Alarm Units and Systems Fifth Edition Underwriters Laboratories Canada CAN ULC S524 06 Standard for the Installation of Fire Alarm Systems Fifth Edition CAN ULC S561 03 Installation and Services for Fire Signal Receiving Centres and Systems First Edition Canada CSA C22 1 Canadian Electrical Code Part I Safety Standard for Electrical Installations NOTE UL 864 9th Edition This system works with ...

Page 92: ...rom a computer in the same IP subnet as the CLSS Gateway with latest version of Google Chrome The latest version of JAVA must also be installed and enabled 8 5 System Architecture These are connections options for the CLSS Gateway architecture An Internet or Intranet IP network connection is used with both architectures 8 5 1 Single Panel Architecture Direct panel connection a connection is made d...

Page 93: ... Architecture The BACnet Feature 8 5 2 NFN Network Architecture NFN network connection a NUP connection is made to an NCM or HS NCM board on the NFN network as the CLSS Gateway Figure 8 2 Notifier System Example 1 A Single NFN Network Figure 8 2 Notifier System Example 1 A Single NFN Network ...

Page 94: ...ture Figure 8 3 Notifier System Example 2 Multiple NFN Networks IP Network BACnet IP Client with Workstation Front End Workstation PC Gateway Workstation Echelon Gateway HS NCM W SF MF or NCM W F NFN Network Style 4 or 6 Echelon Network Wire or Fiber NION NION NFN Network NION CLSS Gateway FACP FACP FACP FACP FACP FACP ...

Page 95: ...ure in CLSS App 8 6 1 To Purchase the BACnet Support 1 Log onto CLSS Site Manager 2 Click on your account name and select Manage Access Figure 8 4 Selecting Manage Access 3 Click Features on the Manage Access page 4 Click Gateway under the Features section 5 Note down the purchased number under Available Features 6 Click PURCHASE at the top right side Figure 8 5 Purchasing the BACnet Support NOTE ...

Page 96: ...ete and refresh the page if required 12 Verify that the purchased number under Available Features is correct 8 6 2 To Activate the BACnet Support 1 Tap Perform Feature Activation on the CLSS App s welcome message Figure 8 6 Feature Activation The First Step 2 Tap Fixed Gateways 3 Select the site of the gateway 4 Find and tap the OC of the gateway 5 Tap ADD ACTIVATION 6 Tap BACnet Support under the...

Page 97: ...arm Security Alarm Life Property Critical Process Alarm Life Property Medical Emergency 3 IssFault Security Trouble Fire Trouble Non Fire Trouble Fire Device or Zone Disabled Non Fire Device Disabled 7 IssActive Non Fire Activation 22 IssSupervisory Supervisory Equipment Supervisory Guard s Tour Event State BACnet Enumeration BACnet LifeSafetyState NFN State 0 EsNormal Normal 1 EsFault Security Tr...

Page 98: ... Reading REAL NA Alarm Status Flags Boolean BACnet Status Flags NFN State 0 0 0 0 Normal 1 0 0 0 InAlarm Fire Alarm Security Alarm Life Property Critical Process Alarm Life Property Medical Emergency 1 1 0 0 InAlarm Fault Security Trouble Fire Trouble Non Fire Trouble PreAlarm 1 0 0 1 InAlarm OutOfService Fire Device or Zone Disabled Non Fire Device Disabled Out of Service Boolean NFN State 0 FALS...

Page 99: ...on BACnet LifeSafetyState NFN State 0 reNoFaultDetec All statuses other than trouble 7 re_UnreliableOt Security Trouble Fire Trouble Non Fire Status Flags Boolean BACnet Status Flags NFN State 0 0 0 0 Normal 1 0 0 0 InAlarm Fire Alarm Security Alarm Life Property Critical Process Alarm Life Property 1 1 0 0 InAlarm Fault Security Trouble Fire Trouble Non Fire Trouble PreAlarm 1 0 0 1 InAlarm OutOf...

Page 100: ...n BACnet LifeSafetyState NFN State 0 IssQuiet Normal 1 IssPreAlarm PreAlarm 2 IssAlarm Fire Alarm Security Alarm Life Property Critical Process Alarm Life Property Medical Emergency 3 IssFault Security Trouble Fire Trouble Non Fire Trouble Fire Device or Zone Disabled Non Fire Device Disabled 7 IssActive Non Fire Activation 22 IssSupervisory Supervisory Equipment Supervisory Guard s Tour Event Sta...

Page 101: ... BACnet Enumeration BACnet LifeSafetyState NFN State 0 NA Maintenance Expected BACnet Enumeration BACnet LifeSafetyState NFN State NA NA NA Event Enable BACnet Enumeration BACnet LifeSafetyState NFN State toOffNormal toFault Direct Reading REAL NA Alarm Status Flags Boolean BACnet Status Flags NFN State 0 0 0 0 Normal 1 0 0 0 InAlarm Fire Alarm Security Alarm Life Property Critical Process Alarm L...

Page 102: ...es and certain other devices Yes No Networking Options Router Clause 6 List all routing configurations e g ARCNET Ethernet Ethernet MS TP etc BACnet to Proprietary ARCnet Fire Network Annex H BACnet Tunneling Router over IP BACnet Broadcast Management Device BBMD Does the BBMD support registrations by Foreign Devices Yes No Character Sets Supported Indicating support for multiple character sets do...

Page 103: ...eature 8 7 1 Direct Connect Node Type Compatibility Refer to Connecting to the Panels on page 105 Table 8 1 Table B 1 Panel Communication Connection Table Supported Panel Types AFP 2800 AFP 3030 N16 INSPIRE NCM NFS 3030 NFS 3030 NFS 320 NFS 320 NFS 640 NFS 640 NFS2 3030 NFS2 3030 NFS2 640 NFS2 640 XLS 120 XLS 140 2 XLS 2000 XLS 3000 ...

Page 104: ...the number of interfaces used Location Requirements Room Temperature 15 27 C 60 80 F Operational Temperature 0 C 49 C 32 F 120 F Relative humidity 93 2 RH Non condensing at 32 C 2 C 90 F 3 F CAUTION THE USEFUL LIFE OF THE SYSTEM S STANDBY BATTERIES AND THE ELECTRONIC COMPONENTS MAYBE ADVERSELY AFFECTED BY EXTREME TEMPERATURE RANGES AND HUMIDITY THEREFORE IT IS RECOMMENDED THAT THIS SYSTEM AND ITS ...

Page 105: ...Compliance Table B 1 Wireless Power Specifications 2 4 GH z TX Power Specifications IEEE 802 11 Mod Rate BW Channel Spec TYP Units Tol dB 11b CCK DSSS 1 to 11 Mbps 20 MHz 1 13 17 5 dBM 2 0 11g OFDM 6 to 54 Mbps 20 MHz 1 13 15 dBM 2 0 11n OFDM MCS 0 7 20 MHz 1 13 15 dBM 2 0 5 GH z TX Power Specifications Std Mod Rate BW Channel Spec TYP Units Tol dB 11a OFDM 6 54 Mbps 20 MHz 36 48 52 64 100 144 15 ...

Page 106: ...al power supply Figure C 1 illustrates the connection options at the top side of the gateway board Figure C 1 Gateway Connections Top Side Figure C 2 illustrates the gateway connection options at the bottom side of the gateway board Figure C 2 Gateway Connection Options Bottom Side Fire Alarm Panel CLSS Cloud Modbus Client Configuration Computer Mobile Connection NUP Ethernet Connection WHITE COLOR...

Page 107: ...ch the S5 switch to ON When there are no signal issues or when the gateway is not at the end of the loop ensure that the S4 and S5 switches are switched to OFF WARNING WHILE THE GATEWAY IS WORKING DO NOT REMOVE CONNECTIONS TO THE GATEWAY CLSS SITE MANAGER AND THE PANEL NOTE When the gateway is communicating to a central station through cellular connection it uses the primary Ethernet connection fo...

Page 108: ...el CPU1 v1 0 703 For SIB version Panel v0 68 For the CLSS Gateway 3 0 4 56 C 3 2 To Use an RS 232 Connection Using an RS 232 cable the CLSS Gateway and the panel are connected The RS 232 port in the gateway board is labeled as 6 in the Figure C 2 1 On the Gateway Side Connect to an RS 232 port of the gateway board 2 On the Panel Side AM8200 Panels AM8200 Panels Connect the White wire to the RX pin...

Page 109: ...teway can connect to the 24V DC power supply module of the AM8200 panel On the Gateway Side Ensure that the RS 232 cable is connected in the RS 232 port of the gateway On the Panel Side Connect the Red wire to the ve pin of the AM82 MB board Connect the Black wire to the ve pin of the AM82 MB board NOTE Use the details given on the power supply module of the panel The panel s power supply to the g...

Page 110: ...2 To Use an RS 485 Connection Using an RS 485 cable the CLSS Gateway and the panel are connected The RS 485 ports in the gateway board are labeled as 3 and 4 in the Figure C 2 1 On the Gateway Side Connect to an RS 485 port of the gateway board 2 On the Panel Side FlexES Panels IQ8 Panels FlexES Panels Connect the ve wire to the Terminal 1 of the panel Connect the ve wire to the Terminal 2 of the ...

Page 111: ...d is labeled as 6 in the Figure C 2 2 On the TTY RS 232 Converter Side From the gateway Connect the Rx wire to the Tx pin of the TTY RS 232 converter Connect the Tx wire to the Rx pin of the TTY RS 232 converter 3 On the Panel Side FlexES Panels FlexES Panels Connect as below Figure C 5 Complete Setup with Both RS 485 and RS 232 Connections TxD B TxD A RxD B RxD A GND UB VCC Rx Rx Rx Tx Tx GND GND...

Page 112: ...teway Side Connect the ve wire to the ve pin of the power supply port Connect the ve wire to the ve pin of the power supply port On the Panel Side Connect the ve wire to the Ub pin of the power supply module Connect the ve wire to the Gnd pin of the power supply module Figure C 6 FlexES Panel Power Connectors NOTE Use the details given on the power supply module of the panel NOTE The panel s power...

Page 113: ... Panels Connecting to the Panels C 4 4 Tools 8000 Settings 1 Select the Serial Interfaces tab in Tools 8000 2 Go to the Serial Interface 1 section 3 Select WINMANG from the Device in use list 4 Go to the Serial Interface 3 section 5 Select Remote Access from the Device in use list 6 Click OK ...

Page 114: ...EI 2 card Connect the In wire to the RXD pin Connect the In wire to the RXD pin Figure C 7 Wiring Diagram RS 485 to SEI2 Connection Power Connection Using a power cable the gateway can connect to the 12V DC power supply module of the panel On the Gateway Side Connect the ve wire to the ve pin of the power supply port Connect the ve wire to the ve pin of the power supply port On the Panel Side Conn...

Page 115: ...s TTY Port Using an RS 232 cable you can connect to the RS 232 port on the panel s serial interface TxD B TxD A RxD B RxD A GND UB VCC Rx Rx Rx Tx Tx GND GND 24 V GND Rx Tx VCC Tx EARTH EARTH RxD RxD 485A_IN 485A_IN Serial Interface Upto 1000 m Upto 15 m IQ8 Panel 88 ǭ67 SRZIVXIV 077 EXI E The connection can also be to 485B_IN and 485B_IN SEI2 ...

Page 116: ...8 000HW E REV F FEB 11 2022 115 ESSER Panels Connecting to the Panels C 4 5 Tools 8000 Settings 1 Double click on Serial Interface in Tools 8000 2 Select RS 232 from the Type of interface list 3 Select Remote Access from the Device in use list 4 Click OK ...

Page 117: ...rt of the gateway Switch the S7 Switch next to the RS 232 port towards NUP_IN Figure C 8 The S7 Switch On the Panel Side Connect the ve wire to the Ub pin of the SEI card Connect the ve wire to the Gnd pin of the SEI card Figure C 9 IQ8 Panel RS 232 Power Connectors NOTE Use the details given on the power supply module of the panel NOTE Although the gateway is capable of receiving 24V DC power it ...

Page 118: ...RS 485 ve wire to the A port Connect the RS 485 ve wire to the B port 3 Power Connection On the Gateway Side In the power supply port labeled 7 in the Figure C 2 Connect the Red wire to the 24V pin Connect the Black wire to the Gnd pin Fire Alarm Panel Models RS 485 UART TTL RS 232 USB Panel firmware version 6 05 01 IFP 75 Yes No No No IFP 300 Yes No No No IFP 300ECS Yes No No No IFP 2100 Yes No N...

Page 119: ...11 2022 118 Farenhyt Panels Connecting to the Panels On the Panel Side In the power board of the panel Connect the Red wire to the ve pin Connect the Black wire to the ve pin Figure C 10 Farenhyt Panel RS 485 Connections Future For panel connection use only the RS 485A port ...

Page 120: ... 7 PROGRAMMING MODE 4 Enter the panel s password in the PROGRAMMING screen The default password is 00000000 5 Select the panel connected with the gateway if it is a standalone panel OR Navigate in the list of panels and select the panel connected with the gateway if it is a multi panel network 6 Select 1 MODULE 7 Select 2 ADD MODULE 8 Select the module of the gateway from the list 9 Select the mod...

Page 121: ...Figure C 2 2 On the Panel Side At the TB9 port in the ANN BUS PRI terminal Connect the RS 485 ve wire to the A port Connect the RS 485 ve wire to the B port 3 Power Connection On the Gateway Side In the power supply port labeled 7 in the Figure C 2 Connect the Red wire to the 24V pin Connect the Black wire to the Gnd pin On the Panel Side In the TB11 port of the panel Connect the Red wire to the v...

Page 122: ...CLSS Gateway Installation and Users Manual P N LS10248 000HW E REV F FEB 11 2022 121 FireWarden Panels Connecting to the Panels Figure C 11 FireWarden Panel RS 485 Connections ...

Page 123: ...nsure 1 TYPE NONE on the ANN BUS MODULE 1 1 screen 12 Press the down arrow button once to go back to the ANN BUS MODULE TYPE screen 13 Press the down arrow button to go to the next screen 14 Select 2 ANN S PG MODULE 15 On the keypad press the Esc key three times to go back to the ANN BUS SELECT screen 16 Select 3 ANN BUS OPTIONS 17 Press 1 ANN S PG OPTIONS on the ANN BUS screen 18 Set CLASS A to Y...

Page 124: ...Panel Side Connect the serial cable in the DB9 serial port of the ANN S PG module on the panel 3 Power Connection On the Gateway Side Connect to the 24V DC external power supply Switch the S7 Switch next to the RS 232 port towards NUP_OUT Figure C 12 The S7 Switch On the Panel Side Connect the power cable to a 24V DC external power source or the panel s power supply NOTE Compatible CLSS Gateway fi...

Page 125: ...CLSS Gateway Installation and Users Manual P N LS10248 000HW E REV F FEB 11 2022 124 FireWarden Panels Connecting to the Panels Figure C 13 FireWarden Panels Printer Port Connections ...

Page 126: ...gh their RS 485 connection The transferred data is stored in the CLSS Site Manager 1 On the Gateway Side 1 Connect the 24 V wire to the IN pin of an RS 485 port 2 Connect the GND wire to the IN pin of an RS 485 port The RS 485 ports are labeled as 3 and 4 in the Figure C 13 2 On the Panel Side E3 Series Panel S3 Series Panel E3 Series Panel At the TB3 terminal of the panel Connect the ve wire to t...

Page 127: ...wire to the TB6 4 pin Power Connection On the Gateway Side Ensure that the power cable is connected with the power port of the gateway The power port is labeled as 7 in the Figure C 13 On the Panel Side Connect the Red wire to the ve pin in the TB3 port Connect the Black wire to the ve pin in the TB3 port Figure C 14 E3 Panel Gateway Connections ...

Page 128: ...wire to the TB3 2 pin At the TB5 terminal of the panel Connect the GND wire to the TB5 1 pin Connect the TxD wire to the TB5 2 pin Connect the SUPV wire to the TB5 3 pin Connect the RxD wire to the TB5 4 pin Power Connection On the Gateway Side Ensure that the power cable is connected with the power port of the gateway The power port is labeled as 7 in the Figure C 13 On the Panel Side Connect the...

Page 129: ...stallation and Users Manual P N LS10248 000HW E REV F FEB 11 2022 128 Gamewell FCI Panels Connecting to the Panels Figure C 15 S3 Series Gateway Connections TB5 and RS 232 Connections The pin connections are as below ...

Page 130: ...RS 232 port of the gateway board The RS 232 port is labeled as 6 in the Figure C 2 2 On the Panel Side The baud rate should be 19200 At the PB6 terminal of the panel Connect the White wire to a Rx1 or Rx2 pin Connect the Brown wire to a Tx1 or Tx2 pin Connect the Green wire to the 0V pin Fire Alarm Panel Models RS 485 UART TTL RS 232 USB COMPACT 24 N No No Yes Yes COMPACT PLUS No No Yes Yes VIGPLU...

Page 131: ... the PB6 Terminal 3 Power Connection On the Gateway Side 1 Ensure that the RS 232 cable is connected with the RS 232 port of the gateway 2 Ensure that the S7 switch next to the RS 232 port is switched towards NUP_IN Figure C 17 The S7 Switch On the Panel Side At the PB15 terminal of the panel Connect the Red wire ve to the 24V pin Connect the Black wire ve to the 0V pin ...

Page 132: ...e USB B side of the cable to the USB port of the panel Figure C 18 Compact Panels USB Connection 3 Power Connection In the PB15 terminal on the panel Connect the gateway to a 24V DC internal power source of the panel CommunicaƟon seƫngs RS232 o Card 0 o Port No 1 or 2 o Mode Standard o Baud Rate 19200 USB o Card 0 o Port No 3 o Mode Standard o Baud Rate 38400 NOTE The external power supply must be...

Page 133: ...Within the panel find the backplane PCB board see Figure C 19 2 Connect the 3 5mm phono socket to the P11 connector on the panel s PCB Figure C 19 Vigilon Panels UART TTL Connection 3 Power Connection On the Gateway Side Connect the power cable to a 24V DC external power source To Use an RS 232 Port via an I O Card Using an add on I O card VIG IOC DOM certain Vigilon panel variants can communicate...

Page 134: ... labeled as 6 in the Figure C 2 2 On the Panel Side 1 Inside the panel enclosure find the backplane PCB board 2 Insert the I O card into the P2 Card 15 Figure C 20 Vigilon Panels I O Card Connection For the P2 Card 15 Connected I O Card 1 In the panel find the RS 485 RS 232 P4 connectors on the main control board 2 Connect the RS 232 cable to the Tx Brown Rx White and 0V Green terminals of the RS ...

Page 135: ...Side Connect the USB C side of the cable to the USB port of the gateway The USB port is labeled as 8 in the figure Figure C 2 2 On the Panel Side In the MCC card on the panel Connect the USB B side of the cable Refer to the figure Figure C 20 3 Power Connection Connect the gateway to a 24V DC external power source NOTE The external power supply must be dedicated and not shared with any other devic...

Page 136: ...ure C 2 2 On the Panel Side Morley DXc Panels Morley DXc Panels In the SK1 terminal of the panel Connect the White wire to the RxD pin Connect the Green wire to the Gnd pin Connect the Brown wire to the TxD pin 3 Power Connection The gateway s RS 232 port can receive its power either from an external power source or from the non resettable internal power of the panel Fire Alarm Panel Models RS 485...

Page 137: ...External Power Supply On the Gateway Side 1 Connect to the 24V DC external power supply or to the panel s 24V DC power port 2 Ensure that the S7 switch next to the RS 232 port is switched towards NUP_OUT Figure C 22 The S7 Switch On the Panel Side In the SK4 or SK5 terminal Connect the RS 232 cable for the non resettable internal power ...

Page 138: ... the CLSS Gateway 1 On the Gateway Side Connect the NUP cable to the NUP port of the gateway board The NUP port is labeled as 6 in the Figure C 23 2 On the Panel Side In the NUP socket of the panel Stand alone Panel Connect the NUP cable Figure C 23 Stand alone Panel NUP Connection Fire Alarm Panel Models RS 485 UART TTL NUP USB ONYX Panels NFS 320 No No Yes No NFS2 640 No No Yes No NFS2 3030 No N...

Page 139: ...nels Connect the NUP cable into an open NUP port of the HS NCM card on the panel If no NUP port is available an additional HS NCM card must be added and connected NOTE For the standard speed network each device should have its NCM card on the panel with an available port Standard NCM NUP ConnecƟon J1 White Green Brown Black Red Required Equipment NUP to NUP cable Standard NCM card ve ve 24 VDC fro...

Page 140: ...necƟon If there are no available NUP ports an addiƟonal High Speed NCM card is required to add the gateway to the network White Green Brown Black Red ve ve Required Equipment NUP to NUP cable High Speed NCM card if no available NUP port HON CGW MBB NoƟĮer Onyx Panel HS NCM NUP NUP NoƟĮer Onyx Panel Network Media to next Panel node Wire Fiber OR Network Media Wire Fiber NUP NUP NUP 24 VDC from pane...

Page 141: ...xternal power source or to the internal power supply of the panel To power the HS NCM or NCM over NUP from the gateway Find the S7 switch next to the NUP port and switch it towards NUP_OUT On the Panel Side Stand alone Panel Ensure that the NUP cable is connected with the NUP port J1 of the panel Network of Panels Connect to a 24V external power source or to the panel s power supply port ...

Page 142: ... cable with a pre formed connector to the NUP port of the gateway board Refer to Figure C 2 where the NUP port is labeled as 6 It is the P7 pin on the gateway board 2 On the Panel Side INSPIRE Panels INSPIRE Panels In the serial communication card on the panel Connect the White wire to the pin 9 CH2 RX B Connect the Green wire to the pin 8 CH2 ISO GND Connect the Brown wire to the pin 10 CH2 TX A ...

Page 143: ...S7 Switch On the Panel Side INSPIRE Panels In the serial communication card or in the I O card Connect the Red wire to the pin 1 Aux DC OUT 24V Connect the Black wire to the pin 2 Aux DC OUT GND External Power Supply Use this option if the gateway is not receiving the power from the panel On the Gateway Side Connect to the power port of the gateway Refer to Figure C 2 where the power port on the g...

Page 144: ...e C 2 2 On the Panel Side At the S BUS board in the ANN BUS PRI terminal Connect the RS 485 ve wire to the A port Connect the RS 485 ve wire to the B port 3 Power Connection On the Gateway Side In the power supply port labeled 7 in the Figure C 2 Connect the Red wire to the 24V pin Connect the Black wire to the Gnd pin On the Panel Side In the power board of the panel Connect the Red wire to the v...

Page 145: ...allation and Users Manual P N LS10248 000HW E REV F FEB 11 2022 144 Silent Knight Panels Connecting to the Panels Figure C 28 Silent Knight Panel RS 485 Connections Future For panel connection use only the RS 485A port ...

Page 146: ...lect 7 PROGRAMMING MODE 4 Enter the panel s password in the PROGRAMMING screen The default password is 00000000 5 Select the panel connected with the gateway if it is a standalone panel OR Navigate in the list of panels and select the panel connected with the gateway if it is a multi panel network 6 Select 1 MODULE 7 Select 2 ADD MODULE 8 Select the module of the gateway from the list 9 Select the...

Page 147: ... terminal Connect the RS 485 ve wire to the A port Connect the RS 485 ve wire to the B port 3 Power Connection On the Gateway Side In the power supply port labeled 7 in the Figure C 2 Connect the Red wire to the 24V pin Connect the Black wire to the Gnd pin On the Panel Side In the power board of the panel Connect the Red wire to the ve pin Connect the Black wire to the ve pin Fire Alarm Panel Mod...

Page 148: ...way Installation and Users Manual P N LS10248 000HW E REV F FEB 11 2022 147 Triga Panels Connecting to the Panels Figure C 29 Triga Panel RS 485 Connections Future For panel connection use only the RS 485A port ...

Page 149: ... 7 PROGRAMMING MODE 4 Enter the panel s password in the PROGRAMMING screen The default password is 00000000 5 Select the panel connected with the gateway if it is a standalone panel OR Navigate in the list of panels and select the panel connected with the gateway if it is a multi panel network 6 Select 1 MODULE 7 Select 2 ADD MODULE 8 Select the module of the gateway from the list 9 Select the mod...

Page 150: ... profile for Ethernet If detector connector is used ensure that the detectors are connected with the detector connector 3 In the CLSS Gateway Ensure that the gateway is connected with CLSS Site Manager via Ethernet or Wireless 1 On the Gateway Side Connect the Ethernet cable to the Ethernet port 2 of the gateway Refer to Figure C 2 where it is labeled as the Ethernet Port 2 It is the J3 pin on the...

Page 151: ...ors Connecting to the Panels External Power Supply On the Gateway Side Connect to the power port of the gateway Refer to Figure C 2 where the power port on the gateway is labeled as 7 It is the P2 pin on the gateway board On the External Power Supply Side Connect to the 24V DC external power supply ...

Page 152: ...r value added services for mobile devices connected with the CLSS Gateway Figure D 1 A Cellular Module To know about installing this device onto the gateway refer to Installing a Cellular Module on page 26 D 1 Operation The cellular modules are plug and play devices which receive power from the CLSS Gateway and provide a cellular communication path ...

Page 153: ...CM ATT HON Region USA Contains FCC ID RI7LE910NAV2 Contains IC 5131A LE910NAV2 Model CCM VZ HON Region USA Contains FCC ID RI7LE910SVV2 Contains IC 5131A LE910SVV2 Model CCM EU Region Europe R TTE GCF Brand Name Verizon Cellular Module AT T Cellular Module EU Cellular Module Module Name CCM VZ HON CCM ATT HON CCM EU Model LE910 SV1 LE910B1 NA LE910 EU1 Supported Regions North America North America...

Page 154: ...12 Clintonville Rd Northford CT 06472 203 484 7161 140 Waterside Rd Leicester LE5 1TN UK 44 0 203 4091779 ...

Reviews: