NX-720
80
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations/
Remarks
Panel tuning mode
PC test mode
Test-
equipment
Unit
Terminal
Unit
Parts
Method
12. CW ID
Deviation *4
[Very Nar-
row]
1) Adj item: [CWID]
Adjust: [
]
Deviation meter
LPF: 15kHz
HPF: OFF
PTT: ON
Press [
] key to
store the adjust-
ment value.
1) Adj item: [CW ID
Deviation (NXDN
Very Narrow)]
Deviation meter
LPF: 15kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
Deviation
meter
Oscillo-
scope
ANT
[Panel
tuning
mode]
[
],
[
]
[PC test
mode]
[
],
[
]
Write the value
376 (Reference
value)
1.00kHz±0.10kHz
*4: Refer to the “Necessary Deviation adjustment item for each signaling and mode” table on page 80.
■
Necessary Deviation adjustment item for each signaling and mode
The following shows the necessary adjustment items for each signaling deviation. Please read the following table like the following
example. In the case of the signaling “QT (Wide)”, this signaling is composed of three elements [Balance, Maximum Deviation (Analog
Wide) and QT Deviation (Wide)]. Please adjust Balance and Maximum Deviation (Analog Wide) before adjusting QT Deviation (Wide).
Mode
Signaling
Necessary adjustment and order
Wide
Narrow
Very Narrow
Analog
Audio
1. Balance adjust
2. Maximum Deviation (Analog Wide)
1. Balance adjust
2. Maximum Deviation (Analog Narrow)
-
QT
1. Balance adjust
2. Maximum Deviation (Analog Wide)
3. QT Deviation (Wide)
1. Balance adjust
2. Maximum Deviation (Analog Narrow)
3. QT Deviation (Narrow)
-
DQT
1. Balance adjust
2. Maximum Deviation (Analog Wide)
3. DQT Deviation (Wide)
1. Balance adjust
2. Maximum Deviation (Analog Narrow)
3. DQT Deviation (Narrow)
-
LTR
1. Balance adjust
2. Maximum Deviation (Analog Wide)
3. LTR Deviation (Wide)
1. Balance adjust
2. Maximum Deviation (Analog Narrow)
3. LTR Deviation (Narrow)
-
DTMF
1. Balance adjust
2. Maximum Deviation (Analog Wide)
3. DTMF Deviation [(Wide)
1. Balance adjust
2. Maximum Deviation (Analog Narrow)
3. DTMF Deviation (Narrow)
-
2TONE
1. Balance adjust
2. Maximum Deviation (Analog Wide)
3. Single TONE Deviation (Analog Wide)
1. Balance adjust
2. Maximum Deviation (Analog Narrow)
3. Single TONE Deviation (Analog Narrow)
-
MSK
(FleetSync)
1. Balance adjust
2. Maximum Deviation (Analog Wide)
3. MSK Deviation (Analog Wide)
1. Balance adjust
2. Maximum Deviation (Analog Narrow)
3. MSK Deviation (Analog Narrow)
-
NXDN
Audio
-
1. Balance adjust
2. Maximum Deviation (NXDN Narrow)
1. Balance adjust
2. Maximum Deviation (NXDN Very Narrow)
CW ID
-
-
1. Balance adjust
2. Maximum Deviation (Analog Narrow)
3. CW ID Deviation (NXDN Very Narrow)
Summary of Contents for NEXEDGE NX-720