TK-5810
(
BG
)
/5810H
(
BG
)
68
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations /
Remarks
Panel tuning mode
PC test mode
Test-
equipment
Unit
Terminal
Unit
Parts
Method
11. DTMF
Deviation
write *4
(Wide)
1) Adj item: [DTMW]
Adjust:
[
✳✳✳
]
Deviation
meter
LPF: 15kHz
HPF: OFF
Detector: ±PEAK/2
PTT:
ON
Press
[PF5] key to
store the adjust-
ment value.
1) Adj item: [DTMF
Deviation (Wide)]
Deviation
meter
LPF: 15kHz
HPF: OFF
Detector: ±PEAK/2
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
Deviation
meter
Oscilloscope
Rear
panel
ANT
[Panel
tuning
mode]
[PF3]
[PF4]
[PC test
mode]
[ ],[ ]
Write the value as
followings.
170 (Reference
value)
3.00kHz
±100Hz
(Narrow)
1) Adj item: [DTMN]
Adjust:
[
✳✳✳
]
Deviation
meter
LPF: 15kHz
HPF: OFF
Detector: ±PEAK/2
PTT:
ON
Press
[PF5] key to
store the adjust-
ment value.
1) Adj item: [DTMF
Deviation (Narrow)]
Deviation
meter
LPF: 15kHz
HPF: OFF
Detector: ±PEAK/2
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
Write the value as
followings.
171 (Reference
value)
1.50kHz
±50Hz
12. Single
Tone
Deviation
write *4
(Wide)
1) Adj item: [2TNW]
Adjust:
[
✳✳✳
]
Deviation
meter
LPF: 15kHz
HPF: OFF
Detector: ±PEAK/2
PTT:
ON
Press
[PF5] key to
store the adjust-
ment value.
1) Adj item: [Single
Tone Deviation
(Wide)]
Deviation
meter
LPF: 15kHz
HPF: OFF
Detector: ±PEAK/2
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
Write the value as
followings.
133 (Reference
value)
3.00kHz
±100Hz
(Narrow)
1) Adj item: [2TNN]
Adjust:
[
✳✳✳
]
Deviation
meter
LPF: 15kHz
HPF: OFF
Detector: ±PEAK/2
PTT:
ON
Press
[PF5] key to
store the adjust-
ment value.
1) Adj item: [Single
Tone Deviation
(Narrow)]
Deviation
meter
LPF: 15kHz
HPF: OFF
Detector: ±PEAK/2
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
Write the value as
followings.
133 (Reference
value)
1.50kHz
±50Hz
13. MSK
Deviation
write *4
(Wide)
1) Adj item: [MSKW]
Adjust:
[
✳✳✳
]
Deviation
meter
LPF: 15kHz
HPF: OFF
Detector: ±PEAK/2
PTT:
ON
Press
[PF5] key to
store the adjust-
ment value.
1) Adj item: [MSK
Deviation (Wide)]
Deviation
meter
LPF: 15kHz
HPF: OFF
Detector: ±PEAK/2
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
Write the value as
followings.
132 (Reference
value)
3.00kHz
±100Hz
*4: Refer to the “Necessary Deviation adjustment item for each signaling and mode” table on page 69.
Balance adjustment is common with the adjustment of all signaling deviation.