background image

KEY-RKPZ Two-Way Radio Keypad

Installation Instructions

Introduction 

The KEY-RKPZ is a radio 

keypad for use with i-on 

and Menvier intrusion 

systems. The  keypad 

provides full access to 

configure, set or unset 

the system, and is an 

essential component 

of Eaton fully-wireless 

intrusion systems.
Being a radio device, the KEY-RKPZ offers ease of installation 

and provides greater flexibility when deciding where to locate 

both the control unit and keypad. 
The keypad uses a separate “base station” (KEY-RKBS), which 

provides a communications bridge between the keypad and 

control unit. The base station uses radio communications with 

the keypad, and a standard RS485 wired connection to the 

control unit. Each base station can communicate with up to two 

keypads.
Features:

 

Radio keypad, giving full access to configure, set or unset the 

system.

 

Easy installation.

 

Internal proximity reader.

 

Backlit display and keys.

 

Navigation keys for installer and user menus, with built-in 

alert LEDs.

 

A, B, C, D setting and unsetting keys, with built-in status 

LEDs. An engineer can configure the keys to set individual 

wards, partitions or part-sets, or to control outputs.

#

1

Summary of Contents for KEY-RKPZ

Page 1: ...separate base station KEY RKBS which provides a communications bridge between the keypad and control unit The base station uses radio communications with the keypad and a standard RS485 wired connecti...

Page 2: ...ential intruders and within the area protected by the intrusion system To ensure correct operation of the internal proximity reader do not locate the keypad Within 1 metre of another proximity reader...

Page 3: ...each corner of the backplate to the mounting surface Figure 5 Figure 5 Mounting the backplate of the keypad Cable entry hole Mounting holes Connections to the control unit 0V 0V 12V 12V A A B B You m...

Page 4: ...e station must have a different setting Note For legacy i on16 and i on40 control units set the links differently for all keypads throughout the system Step 6 Power up 1 Fit three AA batteries into th...

Page 5: ...above message if you pair the keypad and base station and exit the local menu within 30 seconds of powering up the control unit In this case there is no need to reapply power again 2 At the radio key...

Page 6: ...ss or to change the setting Y means enabled and N means disabled or to enter exit the option as applicable 6 Press to save changes or to cancel changes Local menu options Enter Learn Mode Select this...

Page 7: ...ress link at the keypad Enable Prox To extend battery life set to N if proximity tags are not used The default is Y Checking Signal Strength After installing the keypad you can check signal strength u...

Page 8: ...NDINGS AGREEMENTS WARRANTIES EXPRESSED OR IMPLIED INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY OTHERTHANTHOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEENTHE PA...

Reviews: