TK-5810
(
BG
)
/5810H
(
BG
)
64
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations /
Remarks
Panel tuning mode
PC test mode
Test-
equipment
Unit
Terminal
Unit
Parts
Method
4. MCF
(Wide)
[Panel test mode]
1) CH-Sig: 1-1
Filter:
W
[PC test mode]
1) Channel: 1
Signaling:
1
Bandwidth
: 5.0kHz/25.0kHz
Spectrum
analyzer
Tracking
generator
TX-RX CN202
CN207
TX-RX L218
L223
L228
L230
Adjust the coils to obtain the waveform
as shown to below.
REF –20.0 dBm
2 dB/
CAL OFF
SPAN
40.0kHz
RBW
1 kHz
VBW
1 kHz
SWP 200ms
SPAN 40.0 kHz
CENTER 49.9500 MHz
ATT 10 dB
5.5dB or
more
1.5dB MAX
–4
kHz
+4
kHz
–8kHz
+8kHz
Spectrum analyzer setting
Center-f: 49.95MHz
Span: 40kHz
RBW: 1kHz
VBW: 1kHz
TG Level: –20dBm
X dB/div: 2dB
Connect the cable (W05-1000-00) to CN202
and CN207.
(Narrow)
2) Filter: N
2) Channel: 2
Signaling:
1
Bandwidth
: 2.5kHz/12.5kHz
L217
L222
L227
L229
Adjust the coils to obtain the waveform
as shown to below.
REF –20.0 dBm
2 dB/
CAL OFF
TG LEVEL
–20 dBm
RBW
1 kHz
VBW
1 kHz
SWP 150ms
SPAN 30.0 kHz
CENTER 49.9500 MHz
ATT 10 dB
6.0dB or
more
1.0dB MAX
–3
kHz
+3
kHz
–6kHz
+6kHz
Spectrum analyzer setting
Center-f: 49.95MHz
Span: 30kHz
RBW: 1kHz
VBW: 1kHz
TG Level: –20dBm
X dB/div: 2dB
Connect the cable (W05-1000-00) to CN202
and CN207.
5. 2nd Local
1) Adj item: [SLO]
Adjust:
[
✳✳✳
]
Press
[PF5] key to
store the adjust-
ment value.
1) Adj item: [2nd Lo-
cal]
Press [OK] button
to store the adjust-
ment value.
f. counter
TX-RX SLO
[Panel
tuning
mode]
[PF3]
[PF4]
[PC test
mode]
[ ],[ ]
Change the adjust-
ment value adjust-
ment value of the
specifi ed frequency.
50.4MHz±70Hz
6. Quadrature
coil
[Panel test mode]
1) CH-Sig: 1-1
Filter:
N
[PC test mode]
1) Channel: 1
Signaling:
1
Bandwidth
: 2.5kHz/12.5kHz
DVM
TX-RX Test
Point
QUAD
TX-RX L234
Adjust the coil
within the limit of
the specifi ed volt-
age.
1.0V ± 0.05V
7. RTC oscil-
lation
1) Adj item: [RTC]
Adjust:
[
✳✳✳
]
1) Adj item: [RTC Col-
lection]
[Panel
tuning
mode]
[
]
[PC test
mode]
[Auto
Tuning]
[Panel tuning mode]
Press [
] key. After
automatic adjust-
ment adjusted value
is displayed on LCD.
Press [PF5] key to
store the adjustment
value.
[PC test mode]
Press [Start] button
of “Auto Tuning”.
Press [Apply] button
to store the adjust-
ment value after the
automatic adjust-
ment was Finished.
Adjustment of the
transceiver’s inter-
nal clock.