Fault
Cause
Remedy
Brake cannot be released,
air gap is not zero
Air gap too big
Replace the complete brake
Rotor is too thin
Brake was not replaced in
time
Replace the complete brake
Voltage too high
Brake voltage does not
match the rectifier
Adjust rectifier and brake voltage to each other.
Voltage too low
Brake voltage does not
match the rectifier
Adjust rectifier and brake voltage to each other.
Defective rectifier diode
Replace the defective rectifier with a suitable undamaged one.
AC voltage is not mains
voltage
Fuse is missing or defec-
tive
Select a connection with a proper fuse.