Commissioning and operation
Kendrion INTORQ | BA 14.0224 | 02/2021
34
Notice
Operation without dynamic loads (functioning as a pure holding brake)
¾
If the brake is used as a pure holding brake without dynamic load, the friction lining must
be reactivated regularly.
NOTICE
In case of high humidity: If condensed water and moisture are present, provide an appro-
priate ventilation for the brake to ensure that all friction components dry quickly.
At high humidity and low temperatures: Take measures to ensure that the armature plate
and rotor do not freeze.
7.2
Function checks before initial commissioning
DANGER
Danger: rotating parts!
¾
The brake must be free of residual torque.
¾
The drive must not be running when checking the brake.
DANGER
There is a risk of injury by electrical shock!
The live connections must not be touched.
7.2.1
Function check of the brake
If a fault or malfunction arises during the function check, you can find important information for trou-
bleshooting in the chapter Troubleshooting and fault elimination. If the fault cannot be fixed or eliminated,
please contact the customer service department.
7.2.2
Release / voltage control
1. Switch off the supply to the motor and brake securely.
2. When switching on the brake supply, make sure that the motor DOES NOT start up (e.g. remove the
two bridges on the motor terminals).
–
Do not
disconnect the supply connections to the brake.
– If the rectifier for the brake supply is connected to the neutral point of the motor,
also
connect the
neutral conductor to this connection.
DANGER
Danger: rotating parts!
Your system should be mechanically immobilized in the event that it could start moving
when the brake is released.