Technical specifications
Kendrion INTORQ | BA 14.0224 | 02/2021
15
4.3
Switching times
The operating times listed here are guide values which apply to DC switching with rated air gap s
LN
, warm
coil and standard characteristic torque. The given operating times are average values and subject to varia-
tions. The engagement time t
1
is approximately 8 to 10 times longer for AC switching.
t
t
M
t
2
t
12
t
11
t
1
M
dyn
U
0.1M
dyn
Fig. 2:
Operating/switching times of the spring-applied brakes
t
1
Engagement time
t
11
Delay time during engagement
t
2
Disengagement time (up to M = 0.1 M
dyn
)
t
12
Rise time of the braking torque
M
dyn
Braking torque at a constant speed of rotation
U
Voltage
Size
Rated brake
torque at
Δn=100 rpm
M
K
1)
Q
E
1)
S
hue
Operating times
2)
Maximum
speed
Δn
max
DC-side engagement
Disengaging
t
11
t
12
t
1
t
2
[Nm]
[J]
[1/h]
[ms]
[ms]
[ms]
[ms]
[rpm]
01
0.24
200
160
5
7
12
22
5000
02
0.5
400
125
6
10
16
25
5000
03
0.5
800
100
16
17
33
13
5000
1
800
100
7
13
20
28
5000
04
1
1200
90
18
24
42
20
5000
2
1200
90
7
16
23
31
5000
05
2
1800
80
19
30
49
26
5000
4
1800
80
8
19
27
34
5000
Tab. 4:
Switching energy - operating frequency - operating times
1)
The maximum permissible friction energy Q
E
relates to the standard friction lining.
2)
These operating times are specified for usage of coils with a connection voltage of 24 V DC at s
LN
and 0.7 I
N
.