2-30
Close/Open Switching Module Channels
Model 2750 Multimeter/Switch System User’s Manual
ROUTe:CLOSe?
ROUTe:MULTiple:CLOSe?
ROUTe:MULTiple:CLOSe:STATe? <clist>
These query commands are used to determine closed switching module channels.
ROUT:CLOS?
is used to return a list of closed measurement channels including the paired
channel for 4-wire measurements. It will not return non-measurement channels. For
details, see
and related reference information.
ROUT:MULT:CLOS?
is used to return all closed channels (measurement and
non-measurement). For details, see
and related reference information.
ROUT:MULT:CLOS:STAT?
is used to return the state (open or closed) of each specified
channel. A “0” is returned for an open channel, and a “1” is returned for a closed channel.
For details, see
and related reference information.
SYSTem:CARD commands
There is a series of SYSTem:CARD commands that can be used to acquire the following
information about a switching module installed in the Model 2750:
•
Return the serial number and firmware revision.
•
Determine the maximum allowable voltage.
•
Determine if the module supports multiplexer or isolated channels.
•
Determine if the module has built-in temperature sensors for internal cold junction,
thermocouple temperature measurements.
•
Determine which channels are used for volts/2-wire measurements and which are
used for amps.
•
Determine which channels are used for analog or digital output.
•
Determine the totalizer channel (Model 7706 only).
The SYSTem:CARD commands are covered in
2750-900-01.book Page 30 Wednesday, August 3, 2011 7:56 AM
Summary of Contents for 2750
Page 3: ...2750 900 01 book Page 2 Wednesday August 3 2011 7 56 AM...
Page 7: ...2750 900 01 book Page 4 Wednesday August 3 2011 7 56 AM...
Page 17: ...2750 900 01 book Page 10 Wednesday August 3 2011 7 56 AM...
Page 324: ...12 CommonCommands 2750 900 01 book Page 1 Wednesday August 3 2011 7 56 AM...
Page 348: ...15 SCPIReferenceTables 2750 900 01 book Page 1 Wednesday August 3 2011 7 56 AM...
Page 374: ...B Model7700ConnectionGuide 2750 900 01 book Page 1 Wednesday August 3 2011 7 56 AM...
Page 386: ...C StatusandErrorMessages 2750 900 01 book Page 1 Wednesday August 3 2011 7 56 AM...
Page 394: ...D SignalProcessing SequenceandDataFlow 2750 900 01 book Page 1 Wednesday August 3 2011 7 56 AM...
Page 408: ...E MeasurementConsiderations 2750 900 01 book Page 1 Wednesday August 3 2011 7 56 AM...
Page 428: ...G IEEE 488BusOverview 2750 900 01 book Page 1 Wednesday August 3 2011 7 56 AM...