![Keithley 2500 Service Manual Download Page 76](http://html1.mh-extra.com/html/keithley/2500/2500_service-manual_3998319076.webp)
Disassembly
5-3
Static sensitive devices
CAUTION
Many CMOS devices are installed in the Model 2500. Handle all semi-
conductor devices as being static sensitive.
CMOS devices operate at very high impedance levels. Therefore, any static that builds up
on you or your clothing may be sufficient to destroy these devices if they are not handled
properly. Use the following precautions to avoid damaging them:
•
Transport and handle ICs only in containers specially designed to prevent static
build-up. Typically, you will receive these parts in anti-static containers made of
plastic or foam. Keep these devices in their original containers until ready for
installation.
•
Remove the devices from their protective containers only at a properly grounded
work station. Ground yourself with a suitable wrist strap.
•
Handle the devices only by the body; do not touch the pins.
•
Ground any printed circuit board into which a semiconductor device is to be
inserted to the bench or table.
•
Use only anti-static type desoldering tools.
•
Use only grounded-tip solder irons.
•
Once the device is installed in the PC board, it is normally adequately protected,
and you can handle the boards normally.
Assembly drawings
Use the assembly drawings located at the end of this section to assist you as you disassem-
ble and reassemble the Model 2500. Refer to these drawings for information about the
Keithley part numbers of most mechanical parts in the unit. Assembly drawings include:
•
Front panel assembly — 2500-040
•
Chassis/power module assembly — 2500-050
•
Front panel/chassis assembly — 2500-051
•
Chassis assembly — 2500-052
•
Final inspection — 2500-080
Summary of Contents for 2500
Page 2: ...Contains Calibrating and Servicing Information Model 2500 Dual Photodiode Meter Service Manual...
Page 11: ......
Page 13: ......
Page 15: ......
Page 16: ...1 PerformanceVerification...
Page 28: ...2 Calibration...
Page 56: ...3 RoutineMaintenance...
Page 59: ...3 4 Routine Maintenance Model 2500 Service Manual...
Page 60: ...4 Troubleshooting...
Page 74: ...5 Disassembly...
Page 81: ...5 8 Disassembly Model 2500 Service Manual...
Page 82: ...6 ReplaceableParts...
Page 93: ...6 12 Replaceable Parts Model 2500 Service Manual...
Page 94: ...A Specifications...
Page 98: ...B CalibrationReference...
Page 108: ...C CalibrationProgram...
Page 117: ......
Page 119: ......
Page 120: ......
Page 121: ...Keithley Instruments Inc 28775 Aurora Road Cleveland Ohio 44139 Printed in the U S A...