A100
Operation and handling
Operating instructions V1.03
24
© KEBA
Main menu
(1st level)
Display
(2nd level)
Description
Menu 3/4
Settings
Menu 10/16
MSlow
Setup parameters for longer measurement duration (up to
40s) in the
Machine
operating mode (off / on). Default
setting: off
MSlow
Off
Menu 11/16
MSpeed
Speed threshold for the motion detection of the pressure
beam in the
Machine
operating mode, in the
move
down
and
move up
mode from 0 to 200 mm/s, default
setting: 20
2)
MSpeed
20
Menu 12/16
MSens
Trip limit of the acceleration sensor from which a move-
ment of the pressure beam in the
Machine
operating
mode, in the
motion
mode, is detected from 0 to 200,
default setting: 50
3)
MSens
50
Menu 13/16
MAccuracy
Tolerance value from which a plateau in the angle value is
detected from 0 to 50 (1/value) °, default setting: 20
4)
MAccuracy
20
Menu 14/16
MSymRefl
In the
machine
operating mode, filtering reflections that
are not symmetrical to the vertical axis can be configured
(on / off).
On: Reflections that are not symmetrical to the vertical
axis are filtered. Only symmetrical reflections are evalu-
ated for the angle value measurement. (Default setting)
Off: All reflections are evaluated for the angle value mea-
surement.
Menu 15/16
Disc
Formatting the internal memory. All data is deleted.
1)
Disc
Format?
Menu 16/16
Reset
Reset all parameters to the default settings
1)
.
Settings
Reset?
Menu 4/4
ErrLog
No more
errors!
Error memory for messages that have occurred. See
Chapter "Errors".
Axxx
v01.03
Switch-off and display of the installed software version
1)
This function is started by pressing and holding the operating button. By
pressing it 2x briefly, the menu item is exited again without triggering the
function.
2)
If the value is too high, the motion of the press beam may no longer be de-
tected; at a value that is too low, faulty triggering is possible. Use in the
Ma-
chine
operating mode in
move down
and
move up
mode