Acoustic signals
Signal
Description
Single tone
RFID card has been read.
Rising tone sequence
RFID card has been accepted.
Falling tone sequence
RFID card has been rejected (no authorization).
The charging station can also display a text concerning the RFID authoriza-
tion, e.g. "accepted card". This text can be customized via the web interface.
4.2.2
RFID authorization without OCPP backend connection
The authorization function must be activated in the configuration of the mas-
ter charging station.
Teaching in a master RFID card
To teach in a master card, no charging session may be active and no vehicle
may be plugged into the charging station. To access the "Service button",
the housing cover and the connection panel cover must be removed.
1) Press and hold the "Service button" in the connection panel until the
second signal tone is sounded (approx. 10s).
The charging station will then automatically perform a restart, deleting all
previously taught-in cards, if necessary.
2) The charging station will be available again after 30 seconds.
3) After the waiting time, the first three segments of the led bar are illumi-
nated. A master card can be taught in for 30 seconds by holding it in
front of the RFID reader.
A successful programming process is confirmed by a rising tone se-
quence.
Teaching in a slave RFID card
To teach in a slave card, no charging session may be active and no vehicle
may be plugged into the charging station.
1) Hold the master card in front of the RFID reader and wait for the rising
tone sequence.
2) Then hold the slave card to be programmed in front of the RFID reader
within 10 seconds and wait for the signal tone.
3) Confirm the teach-in process by holding up the master card again within
5 seconds. The process is completed with a rising tone sequence.
Summary of Contents for KeContact P30 x-series
Page 1: ...KeContact P30 x series Konfigurationshandbuch Configuration manual ...
Page 2: ......
Page 3: ...KeContact P30 x series Ladestation Konfigurationshandbuch V 4 02 Originalbetriebsanleitung ...
Page 75: ......
Page 76: ...KEBA AG Headquarters Gewerbepark Urfahr 4041 Linz Austria www keba com 98412 ...