32
cONNEcTION
4.4.1 Auxiliary fan (optional)
Externally cooled motors can optionally be equipped with an additional electric fan. The
auxiliary fan must be externally supplied with voltage and switched on. The fan is mount-
ed opposite the coupling side to ensure axial ventilation. The air is drawn in from the rear
of the motor and directed to the flange side.
NOTICE
Damage due to overheating !
►
Keep the minimum distance for the supply air.
►
Prevent external air turbulence at the motor inlet/outlet.
►
Keep the motor away from additional heat sources (e.g. other devic-
es, sunlight).
Motor type
SE cf
Sf cf
SG cf
Mains phases
1~
Rated input voltage
U
N
/ V
230
200...240
Mains frequency
f
N
/ Hz
50
60
50
60
50...60
Rated input current
I
N
/ A
0.25
0.23
0.18
0.22
1.4
Minimum distance for the supply air
l
_min
/ mm
104
83
127
Fan protection class
IP22
IP44
IP54
Table 6:
Technical data auxiliary fan
NOTICE
Use under difficult environmental conditions !
Blocking the fans !
►
Maintain the fan regularly to avoid dirt deposits on the impeller.