28
TecHNIcAL DATA G6 230V cLASS
3.2 Technical data G6 230V class
Unit size
07
09
Housing
A
Phases
1
Rated apparent output power
S
out
/ kVA
1.6
2.8
Max. rated motor power
P
mot
/ kW
0.75
1.5
Rated output current
I
N
/ A
4.0
7.0
Rated output current UL
I
N_UL
/ A
4.1
6.8
Short time current limit
1)
I
HSR
/ %
180
Overcurrent
1)
I
OC
/ %
216
Maximum current at 0Hz / corner frequency
f
d
at
f
S
= 4 kHz
1)
I
f0/Ifd
/ %
100 / 180
100 / 180
Maximum current at 0Hz / corner frequency
f
d
at
f
S
= 8 kHz
1)
I
f0/Ifd
/ %
100 / 180
100 / 150
Corner frequency
f
d
/ Hz
6
Rated input current
I
in
/ A
8
14
Rated input current UL
I
in_UL
/ A
8
14
Max. permissible main fuse type gG
I
_max
/ A
20
20
Rated switching frequency
2)
f
SN
/ kHz
8
4
Max. switching frequency
2)
f
S_max
/ kHz
8
8
Power dissipation at nominal operating
3)
P
D
/ W
45
63
Power dissipation standby (no control release)
3)
P
D_nop
/ W
8
Max. heat sink temperature
T
HS
/ °C
90
Temperature for derating the switching frequency
4)
T
dr
/ °C
85
Temperature for uprating the switching frequency
4)
T
ur
/ °C
80
Min. braking resistor
R
B_min
/ Ω
56
Max. braking current
I
B_max
/ A
7.5
Rated input voltage
U
N
/ V
230 (UL: 240)
Input voltage range
U
in
/ V
195…264 ±0
Mains frequency
f
N
/ Hz
50 / 60 ±2
Rated input voltage DC
U
N_dc
/ V
325 (UL: 340)
Input voltage range at DC supply
U
in_dc
/ V
275…373 ±0
DC switch-off level „Error! Underpotential“
U
UP_dc
/ V
216
Switching level DC braking resistor
U
B_dc
/ V
380
DC switch-off level „Error! Overpotential“
U
OP_dc
/ V
400
Output voltage
5)
U
out
/ V
3 x 0…
U
in
Output voltage at DC devices
5)
U
out_dc
/ V
3 x 0…
U
in_dc
/ √2
Output frequency (depending on the operating mode)
2)
f
out
/ Hz
0…400 (
f
s
= 4 kHz)
0…599 (
f
s
= 8 kHz)
Insulation resistance @
U
dc
= 500 V
R
iso
/ MΩ
10
Minimum waiting period between two switch-on procedures
t
/ min
5
Table 7:
Technical data 230V class
1)
The values refer percentage to the rated output current I
N
.
2)
The output frequency is to be limited in such a way that it does not exceed 1/10 of the switching frequency.
3)
Rated operation corresponds to U
N
= 230 V; f
SN
; f
out
= 50 Hz (typically value).
4)
On reaching the temperature T
dr
the switching frequency is step down. The switching frequency is increased again on cooling down
to temperature T
ur
.
5)
The voltage at the motor is dependent on the series-connected units and on the control method
,
=>
„Calculation of the motor voltage“
The technical data are for 2/4-pole standard motors. With other pole numbers
the drive converter must be dimensioned onto the rated motor current. Contact
KEB for special or medium frequency motors.