3.1.2 Mechanical ambient conditions
Storage
Standard
class
Notes
Vibration limits
1M2
Vibration amplitude 1.5 mm (2…9 Hz)
Acceleration amplitude 5 m/s² (9…200 Hz)
Shock limit values
1M2
40 m/s²; 22 ms
Transport
Standard
class
Notes
Vibration limits
2M1
Vibration amplitude 3.5 mm (2…9 Hz)
Acceleration amplitude 10 m/s² (9…200 Hz)
(Acceleration amplitude 15 m/s² (200…500 Hz))*
Shock limit values
2M1
100 m/s²; 11 ms
Operation
Standard
class
Notes
Vibration limits
3M4
Vibration amplitude 3.5 mm (2…9 Hz)
Acceleration amplitude 10 m/s² (9…200 Hz)
–
Vibration amplitude 0.075 mm (10…57 Hz)
Acceleration amplitude 10 m/s² (57…150 Hz)
Shock limit values
3M4
100 m/s²; 11 ms
Table 3:
Mechanical ambient conditions
*Not tested
3.1.3 chemical / mechanical active substances
Storage
Standard
class
Notes
Contamination
Gases
1C2
–
Solids
1S2
–
Transport
Standard
class
Notes
Contamination
Gases
2C2
–
Solids
2S2
–
Operation
Standard
class
Notes
Contamination
Gases
3C2
–
Solids
3S2
–
Table 4:
Chemical / mechanical active substances
26
OPerATING cONDITIONS
Summary of Contents for COMBIVERT G6 series
Page 2: ......
Page 50: ...50 NOTES ...