33
DIMeNSIONS AND WeIGHTS
3.4.1 control cabinet installation
The power dissipation for the control cabinet dimension is to be taken from the technical
data.
Mounting distances
Dimension Distance in mm
Distance in inch
A
B
D
E
F
C
D
A
150
6
B
100
4
C
30
1.2
D
0
0
E
0
0
F
1)
50
2
1)
Distance to preceding elements in the control cab-
inet door.
Figure 4:
Mounting distances
3.4.1.1 Ventilation in the control cabinet
If construction-conditioned the control cabinet cannot be without indoor ventilation, ap-
propriate filters must avoid suction of foreign objects.
Installation of the drive converter
For reliable operation, the drive converter must be mounted without clearance
on a smooth, closed, bare metal mounting plate.
Direction of the air
flow
Front and side view of the coolant inlet
Coolant outlet
Coolant inlet
Figure 5:
Control cabinet ventilation