9.2 Technical data of COMbIVERT drive converters
OMBIVERT F5 drive converter precharging by AIC at an ambient temperature
T
a
= 45°C
and
U
N_max
= 440V. Corresponding higher charging currents are expected at higher
mains voltages. In this case please contact KEB!
Size
Housing
P
N
I
N
C
int
Load-shunt
Max.
charging
current
R
Type
400V
kW
A
uF
Ω
–
A
5
B
0.37
1.3
180
33
NTC
19
7
B
0.75
2.6
180
33
NTC
19
9
B
1.5
4.1
300
33
NTC
19
10
B
2.2
5.8
345
10
NTC
62
12
B
4
9.5
470
10
NTC
62
7
D
0.75
2.6
180
33
NTC
19
9
D
1.5
4.1
300
10
NTC
62
10
D
2.2
5.8
345
10
NTC
62
12
D
4
9.5
470
10
NTC
62
13
D
5.5
12
580
10
NTC
62
14
D
7.5
16.5
650
10
NTC
62
12
E
4
9.5
470
20
NTC
31
13
E
5.5
12
580
20
NTC
31
14
E
7.5
16.5
650
20
NTC
31
15
E
11
24
940
20
NTC
31
16
E
15
33
1290
20
NTC
31
14
G
7.5
16.5
650
10
–
62
15
G
11
24
940
10
–
62
16
G
15
33
1290
10
–
62
17
G
18.5
42
1640
10
–
62
18
G
22
50
1875
6
–
104
16
H
15
33
1290
20
–
31
17
H
18.5
42
1640
20
–
31
18
H
22
50
1875
20
–
31
19
H
30
60
2700
20
–
31
20
H
37
75
3900
20
–
31
18
R
22
50
1875
5.0
–
–
19
R
30
60
2700
5.0
–
–
20
R
37
75
3900
5.0
–
–
continued on the next page