6.2.1 Cross-sections and tightening torques of the terminals
No.
Permissible cross-section flexible with wire-end ferrule
Tightening torques
mm²
AWG
Nm
lb inch
min
max
min
max
1
0.25
4
24
10
0.6
5
2
0.25
1.5
26
14
0.6
5
3
Screw M4 for ring crimp connector
1.3
11
4
6
16
22
8
1.2
11
5
2.5
35
12
2
4.5
40
6
0.5
2.5
21
12
0.6
6
7
1)
16
50
6 AWG
1/0 MCM
6…8
75
8
2)
35
90
4 AWG
2/0 MCM
15...20
180
9
0.2
4
24 AWG
10 AWG
0.6
5.3
10
10 mm stay bolt for ring crimp connector
25
220
11
50
150
1/0 AWG
300 MCM
25…30
270
12
10 mm stud for ring crimp connector and for DC connection
50...150 qmm
25
220
13
12 mm stud for ring crimp connector
max. 2 ring crimp connectors with 240 mm² for each
35
310
Table 16:
Cross-sections and tightening torques of the terminals
1)
Line applies to F5 housing R device size 20.
2)
Line applies to F5 housing R device size 22.