Parameter Tables
80
6.5 dr-Parameter
6.6 cn-Parameter
Size
No. Name
Adr.
(hex)
P E ro Res.
Lower
Limit
Upper
Limit
Default
Value
Unit
dr
1 Rated Motor Speed
2401
•
1
0
32767
1500 rpm
dr
2 Rated Motor Current
2402
•
0,1
0
370
7,5
A
dr
3 Rated Motor Frequency
2403
•
0,0125
0 409,58
50
Hz
dr
4 Rated Motor Cos (phi)
2404
•
0,01
0,5
1
0,8
dr
5 Motor Terminal
Resistance
2405
•
0,01
0
max
0 Ohm
dr
12 Rated Motor Voltage
240C
•
1
150
500
400
V
Size
No. Name
Adr.
(hex)
P E ro Res.
Lower
Limit
Upper
Limit
Default
Value
Unit
cn
0 Control Mode
2500
•
1
0
3
3
cn
1 Slip Compensation Gain
2501
•
0,01
-2,5
2,5
0
cn
2 Torque Compensation
Gain
2502
•
0,01
-2,5
2,5
0