di - Parameter
63
ANTRIEBSTECHNIK
Determines the strobe mode.
Parameter Value Strobe Mode
0
The current input state is stored with the positive slope
of the strobe signal.
1
As long as the strobe signal is inactive, then all the
input signals are inactive.
When the strobe signal is active, then the input signals
are accepted.
di.19 = 0 :
di.19 = 1 :
di.20 specifies the operational mode of signals F and R (rotation presetting by
terminal).
di.20 = 1:
Terminal F
Terminal R Direction of Rotation
0
0
LS
0
1
Reverse
1
0
Forward
1
1
Forward
di.20 = 0:
Terminal F Terminal R Direction of Rotation
0
0
LS
0
1
LS
1
0
Forward
1
1
Reverse
Select Strobe
Mode (di.19)
Strobe signal
Inputsignal for trigger unit
Cycle (4 ms)
Input signal for strobe
Strobe created signal 1 (for trigger unit)
Strobe created signal 2 (for trigger nit)
Strobe signal
Inputsignal for trigger unit
Cycle (4 ms)
Inputsignal for strobe
Strobe created signal 1 (for trigger unit)
Strobe created signal 2 (for trigger unit)
Rotation Input
(di.20)
Summary of Contents for COMBIVERT F4-S/1.2