GB 38
GB
LF.71
LF.71
stop switch
8. Parameter Description
Crawl Path Optimization
Speed V
2
Unit:
centimeter
Value range:
0.0...200.0 cm
Factory setting:
0.0 cm
Crawl Path Optimization
Rated Speed V
N
Crawl Path Optimization
Speed V
1
Unit:
centimeter
Value range:
0,0...200,0 cm
Factory setting:
0,0 cm
V
N
V
E
t
deceleration point
V
Crawl Path Optimization
Speed V
E
Unit:
centimeter
Value range:
0,0...200,0 cm
Factory setting:
0,0 cm
Function see parameter LF.71
Unit:
millimeter
Value range:
0...300 mm
Factory setting:
0 mm
The levelling position can be exactly adjusted with the crawl path
optimization. Condition: the stop switches in all floors have the same
distances to the levelling position for both directions. The crawl
speed (LF.41) and stopping jerk (LF.54) must be adjusted before the
path optimization crawl speed.
Function see parameter LF.71.
LF.74
LF.74
For optimization see display LF.92!
V
N
V
V
E
t
Summary of Contents for COMBIVERT F4-F