![KEB COMBIVERT F4-F Instruction Manual Download Page 34](http://html2.mh-extra.com/html/keb/combivert-f4-f/combivert-f4-f_instruction-manual_3831709034.webp)
GB 34
GB
LF.50
LF.50
LF.51
Unit:
meter per second
3
Value range:
off, 0,11...9,99 m/s
Factory setting:
0,60 m/s
3
Adjusted value:
dependent on the mechanical system
(adjustment values which are too high can
lead to oscillations in the cabin)
General: The jerk or shock, which always occurs during the
accleration process, is crucial for the comfort of passengers in a
passenger lift. This causes objects on conveyor systems to topple
over or sway and puts a lot of stress on the mechanical components.
Each person expierences this 'shock' differently, depending on their
age, physical and mental state and whether they awaited this
movement or not.
Empirical values: 0.5...0.8 m/s
3
for retirement homes, hospitals,
apartment buildings
0.8...1.2 m/s
3
for office buildings, banks etc.
Set Speed of Door Drive
Starting Jerk
Unit:
meter per second
Value range:
0.000...LF.20
Factory setting:
0.000 m/s
Adjusted value:
dependent on the distance between the
floors
8. Parameter Description
Set Value V
1
,
Intermediate Speed 1
Unit:
meter per second
Value range:
0.000...LF.20
Factory setting:
0.000 m/s
Adjusted value:
dependent on the distance between the
floors
Set Value V
2
,
Intermediate Speed 2
Unit:
rpm
Value range:
0.0...3000,0 rpm
Factory setting:
0.0 rpm
! See pages GB 14 - GB 15 !
higher
values
lower values
V
t
Summary of Contents for COMBIVERT F4-F
Page 65: ...ANTRIEBSTECHNIK...