40
Shop Online
CLASSIC 800 Product Manual
Troubleshooting
How to Reset the CLASSIC Factory Settings
To reset the CLASSIC to factory default settings press the following 3 buttons:
•
LEFT ARROW - RIGHT ARROW - RUN
simultaneously until all LED’s flash.
•
A successful reset will be indicated by five consecutives flashes of all LEDs followed by
a pause and two more flash.
•
Warning:
All configuration changes will be lost and the unit set back to the factory defaults
•
Should not be performed without consulting Kayden Technical Support
Figure 24 - Resistance Wiring
Resistance Values for Sensor Wiring
Wire Colour
Ohms
Wire Colour
Ohms
Red to Red
50
Black to White
1100*
Blue to Blue
0
Red to any other lead
Infinite
Black to Black
0
Blue to Black
Infinite
Blue to Yellow
1100*
*
Exact value depends on the temperature of the probe tips