Maintenance recommendation
Controller
We recommend performing a regular complete functional test of the system, preferably before the onset of winter, to check that the
entire antenna heating system is operating correctly (see
“Controller functional test” on page 6
).
Sensor system
Once a year, preferably before the onset of winter, the sensors should be wiped over with a moist cloth to remove any heavy dirt.
Heating plates / heating pads
The heating plate or heating pad should be checked for damage at regular intervals to ensure they are in sound condition. Other than
this, the heaters are largely maintenance free once installed.
Technical data
Mechanical data
Housing material:
Polycarbonate
Dimensions:
360 x 254 x 165 mm
Weight:
5.3 kg
Cable inlets:
3 x M12, 5 x M16, 1 x M32/M25
Permissible ambient temperature: -30° to +60° C
Recommended
installation temperature:
+5° to +20° C
Protection class:
IP66
Electrical data
Operating voltage:
230 V~, +6 %/-10 %, 50/60 Hz
Breaking capacity:
16 A
Alarm contact:
8 A / 230 V
Temperature measuring input:
2 x PT 100 temperature
sensor
Moisture measuring input: 2 rod probe
Activation temperature U: +4° C (SRR factory setting)
Setpoint temperature H:
+40° C (ELTC-21 P10 factory
setting)
Adjustment range max. U: -10° to +30° C (SRR)
Adjustment range max. H: -5° to +60° C (ELTC-21 P13/P14)
Display range /
resolution:
-50° to +400° C / 1K (ELTC-21)
Type of control:
Two-point controller
Repair and replacement
KATHREIN Digital Systems GmbH
Customer Service
Eiselauerweg 13
89081 Ulm, Germany
Phone: +49 731 270-909 70
E-mail:
Business hours (CET):
Mon-Thu:
8:00–12:00 and 12:45–17:00
Fri.
08:00 -13:00