C-25 TIMER CONTROL INSTRUCTIONS
Portable Timer with Ground Fault Interrupter
(Unit: 9.8 FLA, 58.8 LRA 120 VAC
Light: 300 W, 120 VAC)
IMPORTANT
This portable timer is designed for CONTROLLING the connected equipment only. Unplug timer before ser-
vicing the unit or the equipment it controls.
THE MANUAL OVERRIDE KNOB IS NOT TO BE USED
AS A POWER DISCONNECT!
For maximum protection against electrical shock hazard, perform test pro-
cedure on G.F.C.I. at least once a month. Mount at least 5 ft. from open water.
G.F.C.I. TEST PROCEDURE
The G.F.C.I. should be checked every month to make sure that it is operating properly. Just follow the simple
instructions below. It is recommended to maintain a maintenance diary of your monthly safety check.
1. Push TEST button, RESET button should pop out from inner surface. This should result in power
being OFF at the outlet protected by the G.F.C.I. Verify by plugging a test lamp into the outlet. Be
sure the timer is in the ON position.
2. If the G.F.C.I. tests okay, restore power by pushing the RESET button back in. THE RESET BUT-
TON MUST BE PUSHED FIRMLY AND FULLY INTO PLACE UNTIL IT LOCKS AND RE-
MAINS DEPRESSED AFTER PRESSURE HAS BEEN REMOVED.
DANGER:
IF RESET BUTTON DOES
NOT
POP OUT, IF TEST LAMP
REMAINS LIT
WHEN RESET BUTTON DOES POP OUT, OR IF THE G.F.C.I.
FAILS TO RESET PROP-
ERLY
,
DO
NOT USE TIMER!
CONTACT A QUALIFIED SERVICE TECHNICIAN!
Failure to use the C-25 with Kasco Fountains will void the warranty and cause the Fountain to not be listed to
UL and CSA standards via ETL.
UNDER NO CIRCUMSTANCES SHOULD ANYONE ENTER THE WATER WHEN A
UNIT IS IN OPERATION!
TIMER-OPERATION INSTRUCTIONS
C-25 Control Box will turn the aerator/fountain
ON & OFF
with the TIMER. Kasco lights will turn
ON
with
the PHOTO EYE and
OFF
with TIMER.
C-25 Control Box is to be used with Kasco Approved Lights
ONLY!
1. Insert “
ON
” (GREEN) and “
OFF
” (RED) trippers into dial at desired
ON
and
OFF
times.
2. Turn dial clockwise one or more revolutions until correct time-of-day (AM or PM) in window is
aligned with the arrow.
3. Plug aerator/fountain cord into the RIGHT hand outlet (labeled
UNIT
).
4. Plug transformer light cord into LEFT hand outlet (labeled
LIGHT
).
FOR TEMPORARY MANUAL OPERATION
Rotate
MANUAL
knob counter-clockwise ( ) to desired
ON
or
OFF
position. Timer will follow next auto-
matic operation.
9