background image

 

 

GENERAL OWNER’S INSTRUCTIONS 

 

INSPECT THE SHIPMENT 

Immediately inspect your Kasco Fountain shipment for any visible damages.  Also cross reference the 
parts supplied with the Parts Included sheet to check for shortages.  Shortages should be reported im-
mediately to your Kasco Marine distributor or representative and damages reported to your carrier and 
Kasco Marine. 

 

CAUTION 

WARNING:  Under NO circumstances should anyone enter the water with the unit in operation.

  

Always operate the unit in the water and keep people and objects clear of the propeller.  Do not lift or 
pull the unit by the electrical cord.  Always use extreme caution around electrical equipment and wa-
ter situations. 

 

ASSEMBLY & INSTALLATION 

Please see the proper Assembly and Installation Instructions enclosed in this manual.  Each is specific 
for your model and size of Fountain.  

Note:  

Use the nylon tie provided to help keep the power cords 

for the unit and lights free of the propeller by tying each cord to either side of the float. If you have a 
light kit, make sure that the unit cord is tied to one side of the float and the light cord to the other for 
balance.

  

Note

: It is extremely important to test the GFI breaker in the control panel upon each instal-

lation/reinstallation of the unit to ensure proper functioning. 

 

WARRANTY 

Kasco Fountains are the result of over 40 years of design and engineering.  Kasco products are built to 
withstand the toughest conditions.  Kasco Marine backs each 3400JF model Fountain with a 2 Year 
Warranty.  This warranty covers any and all manufacturers defects within 2 years from the date of 
purchase (See Warranty, Warranty Claim, & Return Policy on pages 12 & 13).  Please register your 
Fountain online at: 
www.kascomarine.com/general_info_warranty_registration.htm .  

 

USE AND OPERATION 

Kasco Fountains are designed and engineered for continuous duty, such as on fish farms or other 
aquaculture applications, or on-demand use, as needed in a recreational water feature. 

 

During flotation operation, the water is pulled from 360

around the unit and from below the unit.  

The water is pulled upward and thrust through the flotation collar into the air.  

 

Your Kasco Marine Fountain is ready for immediate use (after installation).  The motor and ball bear-
ings are submerged in oil and no further lubrication is needed.  

Make sure to keep the motor housing 

clean from hard water deposits and/or algae. (See Maintenance Recommendations on page 11.) 

 

It is extremely important that proper and sufficient voltage (120V or 240/208V) is supplied to the 
Fountain motor.  Each 120V Fountain is supplied with a UL and CSA approved C-25 GFI Protected 
Control Box.  The Fountain is to be plugged into the C-25 outlet labeled “UNIT”  and the C-25 
plugged into a properly grounded receptacle (See C-25 Instructions on page 9).  Each 240V Fountain 
is supplied with a UL and CSA approved C-85 GFCB Protected Control Panel.  The Fountain is to be 
plugged into the external outlet on the C-85 or hardwired into the panel.  The C-85 must have 4 wire 
service (L1, L2, neutral, and ground) installed by a qualified electrician. (See Instructions on page 10).  
It is extremely important to test the GFI breaker in the control panel upon each installation and rein-
stallation and every month thereafter to ensure proper operation.  

 

Kasco Fountains are lightweight, energy efficient, and easy to install and operate.  We strive to pro-
duce products that exceed customer expectations.  We hope you  enjoy your Kasco Fountain. 

 
 

Summary of Contents for 3400HJF

Page 1: ...Needed Unit Specs Assembly Installation Instructions Pattern Sizes C 25 Instructions C 85 Instructions Maintenance Recommendations Warranty Warranty Claim Return Policy Replacement Parts Assembly Diagram Troubleshooting Tips Customer Repair Form Warranty Registration Information Rev 2 20 07 Made in the USA a 2 3 4 5 7 8 9 10 11 12 13 14 15 16 17 Making A Splash I II III IV V VI VII VIII IX X XI XI...

Page 2: ...all fountain models include control panels with GFI protec tion However it is NEVER recommended to enter the water with the equipment in opera tion Caution should be used when dealing with any electrical equipment with moving parts NEVER run the unit out of water It will damage the seals and create a dangerous situation for the operator Extreme caution should be used around water especially cold w...

Page 3: ...Claim Return Policy on pages 12 13 Please register your Fountain online at www kascomarine com general_info_warranty_registration htm USE AND OPERATION Kasco Fountains are designed and engineered for continuous duty such as on fish farms or other aquaculture applications or on demand use as needed in a recreational water feature During flotation operation the water is pulled from 360O around the u...

Page 4: ...zle 1 7 Cypress Nozzle 1 8 Collar for Cypress Nozzle 1 M Mooring Rope Weights 2 TOOLS SUPPLIES NEEDED A Anchors or stakes for installing unit 2 B 2 Phillips head screw driver C 120V or 240V Electrical Supply near pond on a post with room for mounting the C 25 or C 85 G 10 x 1 long or longer screw s for mounting the C 25 3 or C 85 4 H 9 16 Socket and Ratchet I 9 16 Wrench UNIT SPECS Model Voltage O...

Page 5: ... x 3 1 4 Phillips Pan Head Screws Part D and a 1 4 Flat Washer Part E to secure the float to the motor housing Insert screw with washer through bolt hole in float and into receptacle on the unit Tighten until snug with a Phillips Head screw driver and repeat for 3 remaining screws STEP FIVE Turn secured assembly upside down so the top of the float logo side is face down on the flat surface Place B...

Page 6: ...require an anchor 18 feet horizon tally from the float For ease of removal you may choose to keep at least one anchor within reach from shore just below the water s surface STEP SIX Turn the assembly upright again At this time if the cord contains a metal strain relief you can use the chain connector and attach it in one of the opening at the rope placement The chain connector will easily fit if i...

Page 7: ...ing fountain can either be plugged into the 240V outlet on the right hand side of the C 85 panel or hardwired into the panel PLUG Insert the plug on the unit into the outlet and securely close the outlet cover until it snaps into place Test the GFCB with the test button now and every 30 days HARDWIRE The bottom of the C 85 control panel has several knock outs for hardwiring the unit Re move a knoc...

Page 8: ...e The Cypress nozzle marked C1 on fin makes use of the collar marked C2 on the top rim and the 3 8 x 4 bolt Linden Display Produces a two tiered display with a center column 6 tall by 3 wide and an outer cone 3 5 tall by 14 wide The Linden nozzle marked L inside one of the fins uses the 3 8 x 4 bolt Juniper Display Produces a wide cone of water 3 tall by 20 wide The Juniper nozzle marked with J on...

Page 9: ...ESET BUT TON MUST BE PUSHED FIRMLY AND FULLY INTO PLACE UNTIL IT LOCKS AND RE MAINS DEPRESSED AFTER PRESSURE HAS BEEN REMOVED DANGER IF RESET BUTTON DOES NOT POP OUT IF TEST LAMP REMAINS LIT WHEN RESET BUTTON DOES POP OUT OR IF THE G F C I FAILS TO RESET PROP ERLY DO NOT USE TIMER CONTACT A QUALIFIED SERVICE TECHNICIAN Failure to use the C 25 with Kasco Fountains will void the warranty and cause t...

Page 10: ...AL to proper time of day See step 2 above ON TRIPPER TIME POINTER TIME DIAL OFF TRIPPER MANUAL LEVER Wiring information Copper Conductors Wire Terminal Size Tightening Torque AWG Lb In 14 20 12 20 10 20 8 25 6 35 4 45 3 50 2 50 L2 15 A OPEN 20 A 20 A GFCB L1 N GND TIMER IMPORTANT This control panel must be installed according to the National Electrical Code including article 680 and local code req...

Page 11: ...er However when the water is thrust into the air it is exposed to the colder air temperatures longer and can actually make ice thicker on the pond lake Storage over winter is best in a location that is out of the sun and cool but above 32O F It is not necessary to store Kasco motors upside down All internal seals are fully lubricated while stored in an upright position CLEANING Fountains should be...

Page 12: ...aged by unauthorized tampering The Sacrificial Zinc Anode around the propeller shaft shows significant deterioration The Anode must be inspected periodically and replaced if necessary Warranty Claim Procedure Check the ten digit serial number printed either on the black cover of the motor or on the blue nameplate and determine the year of manufacture according to the serial number scheme below Sam...

Page 13: ...our expense via ground freight within the continental United States Other Repairs Most failed equipment can be repaired at substantially lower costs than replacement with new Please ship ac cording to the instructions in the previous section Again it is best to call ahead for a Return Authorization Number and or Repair Form so we know the repair is coming Kasco Marine offers free estimates on repa...

Page 14: ... 4 5 258476 FLAT WASHER 1 4 4 6 251250 14 X 1 1 4 LONG HEX WASHER HEAD 4 7 990285 SEALING WASHER 1 8 990280 SEALING PLUG 1 9 990400 LIP SEAL 1 10 990275 O RING CORD 1 11 243475 ZINC ASSEMBLY 1 12 334200 PROP 3400J 1 13 334125 MAIN HOUSING 2400J 3400J 1 14 334125 INNER HOUSING 2400J 3400J 1 15 334150 CONE 2400J 3400J 1 16 334175 INNER CHAMBER 2400J 3400J 1 17 334306 6 X 3 4 LONG PHILLIPS HEAD SS 10...

Page 15: ...er Each Kasco Fountain has a Thermal Overload built in that will turn the unit off when it overheats Once the unit has cooled down it will start back up If you are noticing these symptoms the unit should be unplugged immediately because the Thermal Overload will continue to turn on and off until it burns out and damages the motor The unit should be unplugged and taken out of the water to find the ...

Page 16: ...d for by the customer You must include the power cord and cage assembly with each unit sent in for repair to be considered for warranty repair Do not ship the float and or control box with the unit for repair unless otherwise instructed Today s Date ___________________ Customer Information Name _________________ Phone Number _____________________ Address __________________________ Alternate Number...

Page 17: ...register your fountain online at www kascomarine com general_info_warranty_registration htm Also fill in the information below and keep for your records Model Ex 3400JF _______________________________ Serial Ex 7001J31725 ______________________________ Purchase Date _____________________ Purchased From ___________________________________ Registration Date ___________________________ 884180 ...

Reviews: