MODEL: C85

DISPLAY AERATOR CONTROL WITH TIME SWITCH, GFCB,

LIGHTNING ARRESTOR AND 15 AMP GFCI LIGHTING RECEPTACLE

SUITABLE FOR USE WITH SUBMERSIBLE LIGHTS

IN RAINPROOF (TYPE 3R) ENCLOSURE SUITABLE FOR INDOOR OR OUTDOOR USE

40 AMP. MAX PER LEG 120/240 VOLT SINGLE PHASE (THREE WIRE) AC

PUMP CIRCUIT: 3 hp max, 240 Vac, LIGHT CIRCUIT: 120 Vac - 15 amp Max.

MIN 75˚ C SUPPLY CONDUCTORS

PHOTO CONTROL RATINGS: 120 VAC 50/60 HZ. 1800W TUNGSTEN, 8.3A BALLAST

LIGHTNING ARRESTOR RATINGS: 120/240 VAC; MCOV 250 VAC

Note: The short circuit current rating of this panel is 10,000 symmetrical amperes.

TIME SWITCH OPERATING INSTRUCTIONS

 

1. TO SET “ON” AND “OFF” TIMES:

 

Hold TRIPPERS against edge of

 

 

CLOCK-DIAL, pointing to time (AM or 

 

 

PM) when 

ON and OFF operations are 

 

 

desired. Tighten tripper  screws firmly.

 

 

2. TO SET TIME-OF-DAY:

 

 

Pull CLOCK-DIAL outward. Turn in 

 

 

either direction and align the exact time-

 

of-day on the CLOCK-DIAL (the time 

 

now, when switch is being put into 

 

operation) to the pointer.

                                 -DO NOT MOVE POINTER-

• 

TO OPERATE SWITCH MANUALLY: Move MANUAL-LEVER 

below left or right as indicated by arrows. This will not affect the 

next operation.

• 

FOR  MORE  THAN  ONE  DAILY  ON-OFF  OPERATION:

 

Place  additional  tripper  pairs  on  CLOCK-DIAL  (order 

156T1978A). 

• 

IN CASE OF POWER FAILURE: Reset CLOCK-DIAL to proper 

time of day. See step 2 above.

ON

TRIPPER

TIME

POINTER

TIME

DIAL

OFF

TRIPPER

MANUAL

LEVER

                                                                                                                                

Wiring information-Copper 

Conductors
Wire 

Terminal

Size 

Tightening Torque

AWG 

Lb-In

   14 

20 

  12 

20

  10 

20

    8 

25

    6 

35

    4 

45 

    3 

50

    2 

       50

L2

15 A

OPEN (20 A)

20 A

GFCB

L1

N

GND

.

TIMER

IMPORTANT:   

This  control  panel  must  be  installed 

according to the National Electrical Code (including article 680) 

and local code requirements. The main lugs and neutral main are 

suitable for No. 14 to 2 AWG 

COPPER conductors. Follow gauge 

selection  table  and  corresponding  terminal  screw  tightening 

torque requirements below. An additional branch circuit protector 

(20 Amp max) may be installed in the unused position for use as 

an auxiliary circuit. Use only Square D HOM Series circuit break-

ers for addition or replacement (do not exceed ratings on wiring 

diagram). Follow Manufacturers instructions for testing of ground 

fault circuit breakers (GFCB). This panel is equipped with a 120V 

AC - 15 amp duplex GFCI receptacle for connecting a 120V AC 

light  kit  or  an  external  low  voltage  transformer  for  lighting.  The 

receptacle  power  is  controlled  by  the  timer-photoelectric  circuit. 

Refer to the instructions provided with your light kit. After wiring, 

install front panel over wiring compartment.   

KEEP DOOR CLOSED AT ALL TIMES. 

KASCO MARINE, INC., 

800 Deere Road
Prescott, WI 54021-1241 
• 

Phone (715) 262-4488

PHOTO
CONTROL

RELAY

240V.

LIGHTNING ARRESTOR

158PS13244

UL508

UL1563

NEC 680

LR3730

T30004R30

Summary of Contents for 3400HJF

Page 1: ...Needed Unit Specs Assembly Installation Instructions Pattern Sizes C 25 Instructions C 85 Instructions Maintenance Recommendations Warranty Warranty Claim Return Policy Replacement Parts Assembly Diagram Troubleshooting Tips Customer Repair Form Warranty Registration Information Rev 2 20 07 Made in the USA a 2 3 4 5 7 8 9 10 11 12 13 14 15 16 17 Making A Splash I II III IV V VI VII VIII IX X XI XI...

Page 2: ...all fountain models include control panels with GFI protec tion However it is NEVER recommended to enter the water with the equipment in opera tion Caution should be used when dealing with any electrical equipment with moving parts NEVER run the unit out of water It will damage the seals and create a dangerous situation for the operator Extreme caution should be used around water especially cold w...

Page 3: ...Claim Return Policy on pages 12 13 Please register your Fountain online at www kascomarine com general_info_warranty_registration htm USE AND OPERATION Kasco Fountains are designed and engineered for continuous duty such as on fish farms or other aquaculture applications or on demand use as needed in a recreational water feature During flotation operation the water is pulled from 360O around the u...

Page 4: ...zle 1 7 Cypress Nozzle 1 8 Collar for Cypress Nozzle 1 M Mooring Rope Weights 2 TOOLS SUPPLIES NEEDED A Anchors or stakes for installing unit 2 B 2 Phillips head screw driver C 120V or 240V Electrical Supply near pond on a post with room for mounting the C 25 or C 85 G 10 x 1 long or longer screw s for mounting the C 25 3 or C 85 4 H 9 16 Socket and Ratchet I 9 16 Wrench UNIT SPECS Model Voltage O...

Page 5: ... x 3 1 4 Phillips Pan Head Screws Part D and a 1 4 Flat Washer Part E to secure the float to the motor housing Insert screw with washer through bolt hole in float and into receptacle on the unit Tighten until snug with a Phillips Head screw driver and repeat for 3 remaining screws STEP FIVE Turn secured assembly upside down so the top of the float logo side is face down on the flat surface Place B...

Page 6: ...require an anchor 18 feet horizon tally from the float For ease of removal you may choose to keep at least one anchor within reach from shore just below the water s surface STEP SIX Turn the assembly upright again At this time if the cord contains a metal strain relief you can use the chain connector and attach it in one of the opening at the rope placement The chain connector will easily fit if i...

Page 7: ...ing fountain can either be plugged into the 240V outlet on the right hand side of the C 85 panel or hardwired into the panel PLUG Insert the plug on the unit into the outlet and securely close the outlet cover until it snaps into place Test the GFCB with the test button now and every 30 days HARDWIRE The bottom of the C 85 control panel has several knock outs for hardwiring the unit Re move a knoc...

Page 8: ...e The Cypress nozzle marked C1 on fin makes use of the collar marked C2 on the top rim and the 3 8 x 4 bolt Linden Display Produces a two tiered display with a center column 6 tall by 3 wide and an outer cone 3 5 tall by 14 wide The Linden nozzle marked L inside one of the fins uses the 3 8 x 4 bolt Juniper Display Produces a wide cone of water 3 tall by 20 wide The Juniper nozzle marked with J on...

Page 9: ...ESET BUT TON MUST BE PUSHED FIRMLY AND FULLY INTO PLACE UNTIL IT LOCKS AND RE MAINS DEPRESSED AFTER PRESSURE HAS BEEN REMOVED DANGER IF RESET BUTTON DOES NOT POP OUT IF TEST LAMP REMAINS LIT WHEN RESET BUTTON DOES POP OUT OR IF THE G F C I FAILS TO RESET PROP ERLY DO NOT USE TIMER CONTACT A QUALIFIED SERVICE TECHNICIAN Failure to use the C 25 with Kasco Fountains will void the warranty and cause t...

Page 10: ...AL to proper time of day See step 2 above ON TRIPPER TIME POINTER TIME DIAL OFF TRIPPER MANUAL LEVER Wiring information Copper Conductors Wire Terminal Size Tightening Torque AWG Lb In 14 20 12 20 10 20 8 25 6 35 4 45 3 50 2 50 L2 15 A OPEN 20 A 20 A GFCB L1 N GND TIMER IMPORTANT This control panel must be installed according to the National Electrical Code including article 680 and local code req...

Page 11: ...er However when the water is thrust into the air it is exposed to the colder air temperatures longer and can actually make ice thicker on the pond lake Storage over winter is best in a location that is out of the sun and cool but above 32O F It is not necessary to store Kasco motors upside down All internal seals are fully lubricated while stored in an upright position CLEANING Fountains should be...

Page 12: ...aged by unauthorized tampering The Sacrificial Zinc Anode around the propeller shaft shows significant deterioration The Anode must be inspected periodically and replaced if necessary Warranty Claim Procedure Check the ten digit serial number printed either on the black cover of the motor or on the blue nameplate and determine the year of manufacture according to the serial number scheme below Sam...

Page 13: ...our expense via ground freight within the continental United States Other Repairs Most failed equipment can be repaired at substantially lower costs than replacement with new Please ship ac cording to the instructions in the previous section Again it is best to call ahead for a Return Authorization Number and or Repair Form so we know the repair is coming Kasco Marine offers free estimates on repa...

Page 14: ... 4 5 258476 FLAT WASHER 1 4 4 6 251250 14 X 1 1 4 LONG HEX WASHER HEAD 4 7 990285 SEALING WASHER 1 8 990280 SEALING PLUG 1 9 990400 LIP SEAL 1 10 990275 O RING CORD 1 11 243475 ZINC ASSEMBLY 1 12 334200 PROP 3400J 1 13 334125 MAIN HOUSING 2400J 3400J 1 14 334125 INNER HOUSING 2400J 3400J 1 15 334150 CONE 2400J 3400J 1 16 334175 INNER CHAMBER 2400J 3400J 1 17 334306 6 X 3 4 LONG PHILLIPS HEAD SS 10...

Page 15: ...er Each Kasco Fountain has a Thermal Overload built in that will turn the unit off when it overheats Once the unit has cooled down it will start back up If you are noticing these symptoms the unit should be unplugged immediately because the Thermal Overload will continue to turn on and off until it burns out and damages the motor The unit should be unplugged and taken out of the water to find the ...

Page 16: ...d for by the customer You must include the power cord and cage assembly with each unit sent in for repair to be considered for warranty repair Do not ship the float and or control box with the unit for repair unless otherwise instructed Today s Date ___________________ Customer Information Name _________________ Phone Number _____________________ Address __________________________ Alternate Number...

Page 17: ...register your fountain online at www kascomarine com general_info_warranty_registration htm Also fill in the information below and keep for your records Model Ex 3400JF _______________________________ Serial Ex 7001J31725 ______________________________ Purchase Date _____________________ Purchased From ___________________________________ Registration Date ___________________________ 884180 ...

Reviews: