background image

 

 

PARTS INCLUDED 

 

A.  3400JF Aerating Fountain (Unit with cord or unit with 

Disconnect) (1) 

A1. Cord in separate box (1) (depending on size of cord) 
B.  Control Box (C-25 for 120V units in Float box or C-85 

for 240V units in separate box) (1) (Not Pictured) 

C.   Float (with two 50’ mooring ropes attached) (1) 
D.   1/4-20 x 3 1/4” Phillips Pan Head Screw (4) 
E.   1/4” (3/4” outer diameter) Flat Washer (4) 
F.   3/8” Flat Washer (4) 
G.  3/8”-16 Nylon Lock Nut (2) 
H.  3/8”-16 x 1-3/8” Hex Head Bolt (2) 
I.    Bottom Screen Clips (2) 
J.    Nylon Cable Tie 
K. Bottom Screen 
L.  Set of 5 Interchangeable Nozzles (5) (Diagram to Right) 
 

1.  3/8” x 2.25” bolt (1) 

 

2.  3/8” x 4” bolt (1) 

 

3.  Linden Nozzle (1) 

 

4.  Sequoia Nozzle (1) 

 

5.  Juniper Nozzle (1) 

 

6.  Willow Nozzle (1) 

 

7.  Cypress Nozzle (1) 

 

8.  Collar for Cypress Nozzle (1) 

M.  Mooring Rope Weights (2) 
 

TOOLS & SUPPLIES NEEDED 

 

A.  Anchors or stakes for installing unit (2) 
B.  # 2 Phillips head screw driver  
C.  120V or 240V Electrical Supply near pond on a post with room for mounting the C-25 or C-85  
G.  #10 x 1” long or longer screw(s) for mounting the 

C-25 (3) or C-85 (4) 

H.  9/16” Socket and Ratchet  
I. 9/16” 

Wrench 

 
 
 
 
 
 
 
 
 

UNIT SPECS. 

Model   

Voltage 

Operating 

  Lock Rotor   

Control Box   

Fountain Power 

    Amps 

  

 

Amps 

  Connection 

 Connection 

3400JF              110-120 

6.5 @ 120V    18 @ 120V   

C-25 Plugs In   

Plug into C-25 

3400HJF 

208-240 

2.9 @ 240V    9 @ 240V 

 

C-85 Hardwired 

Plug or Hardwire

 

 

 

 

 

 

 

 

 

at shore 

 

into C-85 

Power Cords 

Model Length Voltage Gauge 

Cord Shipped 

Seperately 

3400JF 

50 

120 

16 

No 

3400JF 

100 

120 

14 

No 

3400JF 

150 

120 

12 

Yes 

3400JF 

200 

120 

12 

Yes 

3400HJF 

50 

240 

14 

No 

3400HJF 

100 

240 

14 

No 

3400HJF 

150 

240 

12 

Yes 

3400HJF 

200 

240 

12 

Yes 

Summary of Contents for 3400HJF

Page 1: ...Needed Unit Specs Assembly Installation Instructions Pattern Sizes C 25 Instructions C 85 Instructions Maintenance Recommendations Warranty Warranty Claim Return Policy Replacement Parts Assembly Diagram Troubleshooting Tips Customer Repair Form Warranty Registration Information Rev 2 20 07 Made in the USA a 2 3 4 5 7 8 9 10 11 12 13 14 15 16 17 Making A Splash I II III IV V VI VII VIII IX X XI XI...

Page 2: ...all fountain models include control panels with GFI protec tion However it is NEVER recommended to enter the water with the equipment in opera tion Caution should be used when dealing with any electrical equipment with moving parts NEVER run the unit out of water It will damage the seals and create a dangerous situation for the operator Extreme caution should be used around water especially cold w...

Page 3: ...Claim Return Policy on pages 12 13 Please register your Fountain online at www kascomarine com general_info_warranty_registration htm USE AND OPERATION Kasco Fountains are designed and engineered for continuous duty such as on fish farms or other aquaculture applications or on demand use as needed in a recreational water feature During flotation operation the water is pulled from 360O around the u...

Page 4: ...zle 1 7 Cypress Nozzle 1 8 Collar for Cypress Nozzle 1 M Mooring Rope Weights 2 TOOLS SUPPLIES NEEDED A Anchors or stakes for installing unit 2 B 2 Phillips head screw driver C 120V or 240V Electrical Supply near pond on a post with room for mounting the C 25 or C 85 G 10 x 1 long or longer screw s for mounting the C 25 3 or C 85 4 H 9 16 Socket and Ratchet I 9 16 Wrench UNIT SPECS Model Voltage O...

Page 5: ... x 3 1 4 Phillips Pan Head Screws Part D and a 1 4 Flat Washer Part E to secure the float to the motor housing Insert screw with washer through bolt hole in float and into receptacle on the unit Tighten until snug with a Phillips Head screw driver and repeat for 3 remaining screws STEP FIVE Turn secured assembly upside down so the top of the float logo side is face down on the flat surface Place B...

Page 6: ...require an anchor 18 feet horizon tally from the float For ease of removal you may choose to keep at least one anchor within reach from shore just below the water s surface STEP SIX Turn the assembly upright again At this time if the cord contains a metal strain relief you can use the chain connector and attach it in one of the opening at the rope placement The chain connector will easily fit if i...

Page 7: ...ing fountain can either be plugged into the 240V outlet on the right hand side of the C 85 panel or hardwired into the panel PLUG Insert the plug on the unit into the outlet and securely close the outlet cover until it snaps into place Test the GFCB with the test button now and every 30 days HARDWIRE The bottom of the C 85 control panel has several knock outs for hardwiring the unit Re move a knoc...

Page 8: ...e The Cypress nozzle marked C1 on fin makes use of the collar marked C2 on the top rim and the 3 8 x 4 bolt Linden Display Produces a two tiered display with a center column 6 tall by 3 wide and an outer cone 3 5 tall by 14 wide The Linden nozzle marked L inside one of the fins uses the 3 8 x 4 bolt Juniper Display Produces a wide cone of water 3 tall by 20 wide The Juniper nozzle marked with J on...

Page 9: ...ESET BUT TON MUST BE PUSHED FIRMLY AND FULLY INTO PLACE UNTIL IT LOCKS AND RE MAINS DEPRESSED AFTER PRESSURE HAS BEEN REMOVED DANGER IF RESET BUTTON DOES NOT POP OUT IF TEST LAMP REMAINS LIT WHEN RESET BUTTON DOES POP OUT OR IF THE G F C I FAILS TO RESET PROP ERLY DO NOT USE TIMER CONTACT A QUALIFIED SERVICE TECHNICIAN Failure to use the C 25 with Kasco Fountains will void the warranty and cause t...

Page 10: ...AL to proper time of day See step 2 above ON TRIPPER TIME POINTER TIME DIAL OFF TRIPPER MANUAL LEVER Wiring information Copper Conductors Wire Terminal Size Tightening Torque AWG Lb In 14 20 12 20 10 20 8 25 6 35 4 45 3 50 2 50 L2 15 A OPEN 20 A 20 A GFCB L1 N GND TIMER IMPORTANT This control panel must be installed according to the National Electrical Code including article 680 and local code req...

Page 11: ...er However when the water is thrust into the air it is exposed to the colder air temperatures longer and can actually make ice thicker on the pond lake Storage over winter is best in a location that is out of the sun and cool but above 32O F It is not necessary to store Kasco motors upside down All internal seals are fully lubricated while stored in an upright position CLEANING Fountains should be...

Page 12: ...aged by unauthorized tampering The Sacrificial Zinc Anode around the propeller shaft shows significant deterioration The Anode must be inspected periodically and replaced if necessary Warranty Claim Procedure Check the ten digit serial number printed either on the black cover of the motor or on the blue nameplate and determine the year of manufacture according to the serial number scheme below Sam...

Page 13: ...our expense via ground freight within the continental United States Other Repairs Most failed equipment can be repaired at substantially lower costs than replacement with new Please ship ac cording to the instructions in the previous section Again it is best to call ahead for a Return Authorization Number and or Repair Form so we know the repair is coming Kasco Marine offers free estimates on repa...

Page 14: ... 4 5 258476 FLAT WASHER 1 4 4 6 251250 14 X 1 1 4 LONG HEX WASHER HEAD 4 7 990285 SEALING WASHER 1 8 990280 SEALING PLUG 1 9 990400 LIP SEAL 1 10 990275 O RING CORD 1 11 243475 ZINC ASSEMBLY 1 12 334200 PROP 3400J 1 13 334125 MAIN HOUSING 2400J 3400J 1 14 334125 INNER HOUSING 2400J 3400J 1 15 334150 CONE 2400J 3400J 1 16 334175 INNER CHAMBER 2400J 3400J 1 17 334306 6 X 3 4 LONG PHILLIPS HEAD SS 10...

Page 15: ...er Each Kasco Fountain has a Thermal Overload built in that will turn the unit off when it overheats Once the unit has cooled down it will start back up If you are noticing these symptoms the unit should be unplugged immediately because the Thermal Overload will continue to turn on and off until it burns out and damages the motor The unit should be unplugged and taken out of the water to find the ...

Page 16: ...d for by the customer You must include the power cord and cage assembly with each unit sent in for repair to be considered for warranty repair Do not ship the float and or control box with the unit for repair unless otherwise instructed Today s Date ___________________ Customer Information Name _________________ Phone Number _____________________ Address __________________________ Alternate Number...

Page 17: ...register your fountain online at www kascomarine com general_info_warranty_registration htm Also fill in the information below and keep for your records Model Ex 3400JF _______________________________ Serial Ex 7001J31725 ______________________________ Purchase Date _____________________ Purchased From ___________________________________ Registration Date ___________________________ 884180 ...