background image

10 

English

The water jet that is emitted from the high-pressure 
nozzle results in a repulsion power acting on the 
hand spray gun. Make sure that you have a firm 
footing and are also holding the hand spray gun 
and spray lance firmly.

Never leave the appliance unattended as long as it 
is in operation.

ATTENTION

In case of extended breaks, switch the appliance 
off at the main switch / appliance switch or pull the 
mains plug.

Do not operate the appliance at temperatures be-
low 0 °C.

DANGER

The appliance may not be operated in explosive at-
mospheres.

Never use the appliance to clean objects contain-
ing hazardous substances (e.g. asbestos).

Do not spray flammable liquids.

Never draw in fluids containing solvents or undilut-
ed acids and solvents! This includes petrol, paint 
thinner and heating oil. The spray mist is highly in-
flammable, explosive and poisonous. Do not use 
acetone, undiluted acids and solvents, as they cor-
rode the materials used on the appliance.

Keep packaging films away from children, there is 
a risk of suffocation!

WARNING

According to applicable regulations, the appliance 
must never be used on the drinking water net with-
out a system separator. Ensure that the connection 
of your building water installation on which the 
high-pressure cleaner is operated is equipped with 
a system separator pursuant to EN 12729 Type 
BA.

Water that has flown through a system separator is 
no longer classified as drinking water.

High-pressure hoses, fixtures and couplings are 
important for the safety of the appliance. Only use 
high-pressure hoses, fixtures and couplings rec-
ommended by the manufacturer.

When disconnecting the supply or high pressure 
hose, hot water may leak from the connections af-
ter operation. 

CAUTION

Mind the weight of the appliance when selecting 
the storage location and during transport (see tech-
nical data) to prevent accidents or injuries.

WARNING

This appliance was designed to be used with deter-
gents which are supplied or recommended by the 
manufacturer. The use of other detergents or 
chemicals may compromise the safety of the appli-
ance.

The improper use of detergents can cause severe 
injuries or toxication.

Store detergents away from the reach of children. 

CAUTION

Wear protective clothing and safety goggles to pro-
tect against splash back containing water or dirt.

During the use of high-pressure cleaners aerosols 
can develop. Inhaling aerosols can cause health 
damage.

Depending on the application, completely shielded 
nozzles (e.g. surface cleaner) that significantly re-
duce the emission of aqueous aerosols can be 
used for high-pressure cleaning.

The use of such shielding is not possible with all 
applications.

If the use of a completely shielded nozzle is not 
possible, a respirator of the category FFP 2 or the 
like should be used, depending on the environment 
to be cleaned.

CAUTION

Safety installations serve the protection of the user and 
may not be modified or bypassed.

The appliance switch prevents unintentional operation 
of the appliance.

The lock locks the lever of the trigger gun and prevents 
the accidental start of the device.

If the lever on the trigger gun is released, the pressure 
switch turns off the pump, the high-pressure jet stops. If 
the lever is pulled the pump is turned on again.

Other risks

Working with detergent

Personal protective equipment

Symbols on the machine

The high pressure jet must not be directed at 
persons, animals, live electrical equipment 
or at the appliance itself.
Protect the appliance against frost. 
The appliance must not be directly connect-
ed to the public drinking water network.

Safety Devices

Appliance switch

Lock trigger gun

Auto-stop function

Summary of Contents for K 25 Silent

Page 1: ...Espa ol 4 English 9 Fran ais 14 K 25 Silent 59785950 12 21 CONSUMO DE ENERGIA 1 En Operaci n 1 350 kWh 2 En Modo de Espera N A Modelo K 25 Silent...

Page 2: ...2 1 2 3 16 5 15 14 13 12 6 11 9 8 4 7 10 17...

Page 3: ...3 C D E F G H A B...

Page 4: ...ncidir con la placa de caracter sticas del equipo Por razones de seguridad tambi n recomenda mos utilizar el aparato siempre con un interruptor de corriente por defecto max 30 mA Los cables el ctricos...

Page 5: ...ua muy caliente de las tomas despu s del funcionamiento PRECAUCI N Al seleccionar el lugar de montaje y al transportar tener en cuenta el peso del aparato v ase Datos t cnicos para evitar accidentes o...

Page 6: ...Acoplamiento para mangueras Antes de la puesta en marcha montar las piezas sueltas suministradas con el aparato Ilustraciones v ase la p gina 3 Imagen Atornille la pieza de acoplamiento a la conexi n...

Page 7: ...puma en la pistola pulveri zadora manual y f jela gir ndola 90 Nota De este modo se a ade durante el funciona miento la soluci n de detergente al chorro de agua Roc e la superficie seca con detergente...

Page 8: ...n de alta presi n Desconectar el aparato y volver a conectar la manguera de alta presi n Extraer el tamiz de la conexi n del agua con unos alicates de punta plana y limpiarlo coloc ndolo bajo agua cor...

Page 9: ...sion cable can be hazardous Only use an electrical extension cable which has been approved and labelled for this pur pose and has an adequate cable cross section out doors 1 10 m 1 5 mm2 10 30 m 2 5 m...

Page 10: ...TION Mind the weight of the appliance when selecting the storage location and during transport see tech nical data to prevent accidents or injuries WARNING This appliance was designed to be used with...

Page 11: ...aminations 15 Foam nozzle with detergent container 16 Hose coupling Mount loose parts delivered with appliance prior to start up Illustrations on Page 3 Illustration Screw the coupling element to the...

Page 12: ...paringly on the dry surface and allow it to react but not to dry Spray off loosened dirt with the high pressure jet Release the lever on the trigger gun Lock the lever on the trigger gun During longer...

Page 13: ...nozzle Remove dirt and de bris from the nozzle bore using a needle and rinse through with water from the front Check water flow quantity Slight leakage from the appliance pump is normal If the leakag...

Page 14: ...cord un bran chement lectrique mis en service par un lectri cien conform ment la norme IEC 60364 Branchement l appareil uniquement du courant alternatif La tension doit tre identique avec celle indiqu...

Page 15: ...des arma tures et des raccords recommand s par le fabricant En cas de s paration du flexible d amen e ou haute pression de l eau chaude peut s chapper des raccords pendant le fonctionnement PR CAUTIO...

Page 16: ...ipient de d tergent 16 Raccord pour flexible Monter les pi ces jointes en vrac l appareil avant la mise en service Illustrations voir page 3 Figure Visser le raccord l arriv e d eau de l appareil Figu...

Page 17: ...au r cipient de d tergent Ins rer la buse mousse dans la poign e pistolet et la fixer en effectuant une rotation de 90 Remarque Ainsi la solution de d tergent est m lang e au jet d eau lors du foncti...

Page 18: ...utes jusqu ce qu il s coule de l eau sans bulle du rac cord haute pression Mettre l appareil hors tension et raccorder le flexible haute pression Enlever le tamis de l arriv e d eau l aide d une pince...

Page 19: ......

Page 20: ...www kaercher com serYLFH Alfred K rcher 6 Co KG Alfred K rcher Str 28 40 71364 Winnenden Germany...

Reviews: