BR/BD 100/250 R BP / RI
Technical features
Page 23 / 171
Service Manual 08.2007
1
Connection cable, seat sensor (S10)
2
Connection cable with battery (–)
3
Connector, filling hose
4
Filling hose
5
Level indicator, filling valve
6
Filling valve (18x)
7
Battery (G1) (6.654-136), low
maintenance
8
Connection cable with battery (+)
9
Seat, folded up
10
Central plug (X1)
2.10 Battery (low-maintenance) with filling system
10
1
9
3
8
2
4
6
5
7
All the unit’s electrical components are connec-
ted with the block battery (6.654-136) through
the central plug (10). If the upper section of the
central plug (10) is pulled out the whole unit is
isolated. The electromagnetic brake (Y1) is ac-
tivated.
Note:
An external battery charger is connected to
the upper section of the central plug (10).
Only use distilled water to refill the battery.
–
+
–
+
–
+
–
–
+
+
–
–
–
+
+
+
+
–
–
+
+
–
–
–
+
+
–
–
+
+
–
–
+
+
–
+
–