Unit functions
BR/BD 100/250 R BP / RI
Page 64 / 171
Service Manual 08.2007
3.3.9 Operator functions - manufacture settings
PROCESS SWITCH MENU, BR 100/250 R Manufacture Settings - Dated 12/04
Processing / setting
program switch (S9)
Adjustable process
parameters
Bar display,
Manufacture
setting
Bar display,
MIN/MAX
Notes
1. Drive
(without cleaning
function)
–
–
–
No adjustments planed
2. Wet scrubbing
(with suction)
Water volume
5
1-8
1 = 3.2V,
2 = 3.0V,
3 = 2.8V,
4 = 2.6V,
5 = 2.4V, Ball valve analog /- 0.1V
6 = 2.2V,
7 = 2.0V,
8 = 1.8V
Cleaning agent
metering
0*)
0-5
0 = 0%, chemical pump switched off
1 = approx 1%,
2 = approx 1.5%,
3 = approx 2%,
4 = approx 2.5%,
5 = approx 3%
Brush pressure /ON
4
0-8
0 = 40A, Current consumption of both
rollers
1 = 45A, in 5A steps
2 = 50A...,
3 = 80A
Brush speed (FACT)
Power Clean
Power Clean
Whisper Clean
Fine Clean
Power Clean
= 100% speed
Whisper Clean
= 65% speed
Fine Clean
= 40% speed
Brush after-running
time after stop
2s
0s-3s
Time from machine stoppage, within which
the roller head stays on the floor scrubbing
Working speed
4
1-6
Speed, if the accelerator pedal is fully
depressed:
1 = 1km/h,
2 = 2km/h....,
6 = 6km/h
3. Wet scrubbing
(without suction)
Water volume
5
1-8
see 2.
Chemical metering
0*)
0-5
Brush pressure /ON
4
0-8
Brush speed (FACT)
Power Clean
Power Clean
Whisper Clean
Fine Clean
after stop
2s
0s-3s
Working speed
4
1-6
4. Suction (without
srubbing mode)
Working speed
4
1-6
Brush pressure /ON
4
0-8
5. Polishing
(without suction)
Brush speed (FACT)
Power Clean
Power Clean
Whisper Clean
Fine Clean
see 2.
see 2.
after stop
0s
0s-3s
Working speed
4
1-6
Brush pressure /ON
4
0-8
6. Polishing
(with suction)
Brush speed (FACT)
Power Clean
Power Clean
Whisper Clean
Fine Clean
see 2.
Brush after-running
timeafter stop
0s
0s-3s
Working speed
4
1-6
7. Hand cleaning
with wall-ceiling-
floor tool (optional)
–
–
–
No adjustment planned -
drive mode not possible for safety reasons!
Note:
The cleaning agent metering is deactivated as a standard, identifiable from the message „cleaning agent metering not availa-
ble“. The cleaning agent metering can be activated in the setup menu „system parameters“ (see Chapter 5.3).
Before the cleaning agent metering option is activated you must ensure that the machine is equipped with a pump and cleaning
agent canister with rod probe. The pump and probe must be connected to the cleaning module in accordance with SLP.