Basic settings and service procedures
BR/BD 100/250 R BP / RI
Page 110 / 171
Service Manual 08.2007
5.4.5 Drive sensor (B1)
1
Floor panel
2
Retaining screws (2x), drive sensor
3
Drive sensor (B1)
4
Drive sensor cable
Adjust drive sensor (B1)
– Remove the retaining screws of the floor
panel (1) and remove the floor panel.
– The drive sensor (3) no longer has to be cali-
brated using the retaining screws (2). The
calibration takes place automatically in setup
mode (in the „Parameter menu driving modu-
le“, see Chapter 5.3). To do this, only the upper
drive pedal position must be simulated and
confirmed. The same applies to the lower drive
pedal position.
3
1
2
4
Note:
When installing the floor panel (1) ensure
the drive sensor cable (4) is routed properly.
The cable must not get clamped or jammed.