Basic settings and service procedures
BR/BD 100/250 R BP / RI
Page 86 / 171
Service Manual 08.2007
5.1.5.3 Service-operator menu
Requirements
– Unit is ready for service in test mode
– Program switch (S9) in Pos 5 Polish
– Above the rotary function I-button the call up service/operator menu? display is active
Display
Call up
service/operator
yes
no
LED service flashes
t
t
t
t
t
Display
Quit operator
menu?
Display
Parameter setup
menu?
Display
Diagnosis
information?
View diagnosis
information?
yes
no
yes
no
yes
no
no
no
yes
Module: 00
FZ:
0h
00m
Module: 01
FZ:
0h
00m
Module: 02
FZ:
0h
00m
Module: 03
FZ:
0h
00m
Module: 04
FZ:
0h
00m
Module: 05
FZ:
0h
00m
Module: 06
FZ:
0h
00m
Module: 07
FZ:
0h
00m
Quit Display error
archive
yes
no
t
yes
no
t
no
yes
yes
no
Display
Display contrast
min IIIIII max?
Display
Display internal
marker?
Display
Addr. 28:08
+1:00
+2:
+3:00
Display
Busmon. operation:0
0=off; 1=R/W; 2=W
O MoD 00 CD 00
Addr 00 100 h 00
Module-1
1=F; 2/3=
C; 4/5=H 6=Z; 7=L
Module-2
1=F; 2/3=
C; 4/5=H 6=Z; 7=L
Module-3
1=F; 2/3=
C; 4/5=H 6=Z; 7=L
Module-4
1=F; 2/3=
C; 4/5=H 6=Z; 7=L
Module-5
1=F; 2/3=
C; 4/5=H 6=Z; 7=L
ENC-W:FF PUSH:0
li:0 re:0
F: 0F: 0 M:00
Analog: 0
Cycle time is:
1ms
µs
I: 000A U/O:07/00
Rup: 0 Rdown:0
I-Brush:
0A
Is:0A
T:0ms
Information menu?
Operating notes:
If the i-button is not pressed
within 10 secs before the
Display internal marker?
display appears
the display automatically
switches back to
Call up service/operator
menu?
and the LED service goes out.
Then restart as described.
t
t
Note:
The displays shown
above are solely relevant
for development.
Note:
- If the rotary pulse generator is turned in an anti-
clockwise direction the cursor works in the opposite
direction, i.e. the menu is called up from the last to the first
parameter. The last saved cursor can be called up again
after quitting the menu by switching back to the display
Call up service/operator menu?
- Switch off the key switch (S0) to quit test mode.