BR/BD 100/250 R BP / RI
Technical features
Page 15 / 171
Service Manual 08.2007
2.4 Suction motor (M4)
1
Mounting plate, right-hand fresh water
tank
2
Seat
3
Suction motor (M4, EC Longlife)
4
Dirty water tank
Suction motor (M4)
The suction motor (3) (EC = electronically con-
trolled) generates a vacuum in the dirty water
tank, with which the dirty water is drawn in from
the suction beam.
The suction motor (3) is located behind the right
fresh water tank:
– Drain and remove the fresh water tank.
– Remove the three retaining screws on the
mounting plate (1).
– Push the fresh water tank forwards slightly
and remove upwards.
1
4
2
3