background image

 

G-SA060-002

 

 

2.Electrical Characteristics of MODULES 

 

PRODUCT

THIN-FILM SILICON PV MODULE

 

MODEL: 

G-SA060

 

DATE: April 01, 2006 

SPECIFICATION LISTS 

UNIT 

VALUE 

REMARK 

Performance at STC (stabilized) 

 

 

Nominal Power (Pmax) 

60.0   

Open Circuit Voltage (Voc) 

92.0 

Open circuit Voltage (Voc) at -10°C 

and 1250W/m

2

 

V 101.2 

Short Circuit Current (Isc) 

1.19 

Short Circuit Current (Isc) at 70°C 

and 1250W/m

2

 

A 1.53 

Voltage at Pmax (Vpm) 

67.0 

Current at Pmax (Ipm) 

0.90 

Tolerance: ±10% 

Max. System Voltage 

530 

Fire Rating 

 

Class C 

Dimension 

mm 

990 ± 2.5 x 960 ± 2.5   

Depth mm 

40 

± 

1.0 

Weight kg 

13.7 

 

 

(REMARK) 

1. During initial 6 weeks of operation, the MODULE has higher electrical output than rated 

output (See Performance at STC (stabilized)). The Pmax may be higher by 38% and Imp may 

be higher by 19%. 

 

2. The Electrical characteristics are within ±10% of the indicated values of Isc, Voc, and Pmax 

under standard test conditions (irradiance of 100mW/cm

2

, AM1.5 spectrum, and a cell 

temperature of 25°C (77°F)). 

http://www.wholesalesolar.com/solar-panels.html

Summary of Contents for G-SA060

Page 1: ...060 002 KANEKA Thin Film PV Installation Manual MODULE TYPE G SA060 KANEKA CORPORATION 3 2 4 NAKANOSHIMA KITA KU OSAKA 530 8288 JAPAN reference No G SA060 002 http www wholesalesolar com solar panels...

Page 2: ...Follow the procedure in this manual when installing the MODULE and its platform Beware of electric shock and short circuit as the MODULE generates high tension current when exposed to light Wear a saf...

Page 3: ...G SA060 002 1 Dimensions http www wholesalesolar com solar panels html...

Page 4: ...Pmax Vpm V 67 0 Current at Pmax Ipm A 0 90 Tolerance 10 Max System Voltage V 530 Fire Rating Class C Dimension mm 990 2 5 x 960 2 5 Depth mm 40 1 0 Weight kg 13 7 REMARK 1 During initial 6 weeks of op...

Page 5: ...on UL Listed MODULES should be multiplied by a factor of 125 when determining component voltage ratings conductor capacities fuse sizes and size of controls connected to the MODULE output Refer to Art...

Page 6: ...Installation shall be in accordance with CSA 22 1 Safety Standard for Electrical Installations Canadian Electrical Code Part 1 All mounting hardware shall be stainless steel Method 1 Fix the MODULES t...

Page 7: ...the 2 cramps must be 660 950mm Optimize the tightness of the cramps with greatest care so that the MODULES will not come off and so that the cramps will not break the frames of the MODULES and or glas...

Page 8: ...s for interconnection between the MODULES during array assembly in the field As these connectors can only be assembled in the factory we recommend the use of commercially available output wiring produ...

Page 9: ...ew needs to provide sufficient torque to ensure that the lug is mechanically secure 4 Connect a minimum 10AWG solid conductor copper ground wire to the ground lug You will use stainless steel hardware...

Page 10: ...G SA060 002 7 Limitation See the Attachment A Instruction for using G type UL grade http www wholesalesolar com solar panels html...

Reviews: