background image

Service instructions

for contractors

VIESMANN

Vitovolt

For applicability, see the last page

VITOVOLT

5692 807 GB

6/2009

Please keep safe.

Summary of Contents for Vitovolt 100 RA1

Page 1: ...Service instructions for contractors VIESMANN Vitovolt For applicability see the last page VITOVOLT 5692 807 GB 6 2009 Please keep safe ...

Page 2: ... pre vention of accidents all legal instructions regarding envi ronmental protection the Code of Practice of relevant trade associations all current safety regulations as defined by DIN EN DVGW VDE and all locally applicable standards Working on the system Isolate the system from the power sup ply and check that it is no longer live e g by removing a separate fuse or by means of a main isolator Sa...

Page 3: ... the heating system can com promise its function Installing non authorised components and non approved modifications or conversions can compromise safety and may invalidate our warranty For replacements use only orig inal spare parts supplied or approved by Viessmann Safety instructions Safety instructions cont 5692 807 GB ...

Page 4: ... inspection and maintenance 5 Further details regarding the individual steps 6 Parts lists Vitovolt 100 parts list 8 Vitovolt 200 parts list 10 Commissioning service reports 12 Specification 13 Certificates Declaration of conformity 15 Index Index 5692 807 GB ...

Page 5: ...aintenance steps Page 1 Shutting down the system 6 2 Cleaning photovoltaic modules 6 3 Checking the inverter 6 4 Checking the function of the safety equipment 6 5 Checking the electrical connections 6 6 Starting the system 7 Commissioning inspection maintenance Steps commissioning inspection and maintenance 5692 807 GB ...

Page 6: ...on Cleaning photovoltaic modules For shading through fallen leaves or other contamination clean the photovol taic modules with a damp cloth NEVER use aggressive cleaning agents Checking the inverter See the inverter Operating and installa tion instructions Checking the function of the safety equipment Check the earth bonding connections on the substructure of the photovoltaic mod ules if installed...

Page 7: ...7 Starting the system Observe operating instructions of instal led components Commissioning inspection maintenance Further details regarding the individual steps cont 5692 807 GB ...

Page 8: ...or mounting rails 003 Connecting and extension cables 15 m 004 Extension cable 3 m 007 Centre clamp pack 008 End clamp pack 009 Support pack 010 Pack of end clamps for freestand ing installations 011 Pack of centre clamps for free standing installations Parts not shown 005 Adaptor set 006 Spare part set 012 Installation instructions 013 Operating instructions 014 Service instructions Parts lists V...

Page 9: ...9 003 011 010 002 007 009 004 008 Parts lists Vitovolt 100 parts list cont 5692 807 GB ...

Page 10: ...itovolt 200 parts list 002 Connecting elements for mounting rails 003 Connecting and extension cables 15 m 004 Extension cable 3 m 007 Centre clamp pack 008 End clamp pack 009 Support pack Parts not shown 001 Vitovolt 200 005 Adaptor set 006 Spare part set 010 Installation instructions 011 Operating instructions 012 Service instructions Parts lists Vitovolt 200 parts list 5692 807 GB ...

Page 11: ...11 002 003 007 009 004 008 Parts lists Vitovolt 200 parts list cont 5692 807 GB ...

Page 12: ...tenance Service Maintenance Service Maintenance Service date by Maintenance Service Maintenance Service Maintenance Service date by Maintenance Service Maintenance Service Maintenance Service date by Commissioning service reports Commissioning service reports 5692 807 GB ...

Page 13: ...35 Vitovolt 200 Typ e RC2 RD2 RE2 RI2 RF2 RJ2 RG2 RH2 Rated output Wp 175 170 160 165 155 217 Output tolerance 4 4 4 4 4 4 Voltage at MPP 1 V 35 9 35 5 33 6 33 8 33 3 29 6 Current at MPP 1 A 4 87 4 78 4 77 4 88 4 66 7 33 Idle voltage STC V 44 3 44 0 42 8 43 1 42 4 36 4 Short circuit current STC 2 A 5 34 5 30 5 23 5 32 5 15 8 10 Note For type RE2 RF2 RG2 RH2 RI2 RJ2 A tolerance of 10 applies to all...

Page 14: ... current STC 2 A 5 14 5 20 7 89 8 12 Vitovolt 200 Typ e SG2 SH2 Rated output Wp 170 175 Output tolerance 3 3 Voltage at MPP 1 V 35 6 35 8 Current at MPP 1 A 4 80 4 90 Idle voltage STC 2 V 44 4 44 7 Short circuit current STC 2 A 5 15 5 23 1 Maximum power point maximum output at STC 2 Standard test conditions irradiation 1000 W m2 cell temperature 25 C and atmospheric nuclear number AM 1 5 G Specifi...

Page 15: ...ts Vitovolt conform to the following standards DIN 1055 EN 50178 EN 60146 1 1 EN 61215 EN 61646 EN 61730 In accordance with the following Directives this product is designated with _ 2006 95 EC 2004 108 EC Allendorf 1 February 2009 Viessmann Werke GmbH Co KG pp Manfred Sommer Certificates Declaration of conformity 5692 807 GB ...

Page 16: ...itovolt 200 type RD2 Vitovolt 200 type SG2 Part no 7373 084 Part no 7419 440 Vitovolt 200 type RE2 Vitovolt 200 type SH2 Part no 7374 114 Part no 7419 441 Vitovolt 200 type RF2 Vitovolt 200 type SI2 Part no 7374 115 Part no 7419 438 Vitovolt 200 type RG2 Vitovolt 200 type SJ2 Part no 7160 677 Part no 7419 439 Vitovolt 200 type RH2 Part no 7419 445 Viessmann Limited Hortonwood 30 Telford Shropshire...