KANEKA G-SA060 Installation Manual Download Page 2

 

G-SA060-002

 

 

Warning

 

Meaning of signs 

 

Not Allowed 

No Disassembly 

 

No Touching

 

Procedures Must be Followed. 

Beware of Electric Shock 

 

 

 

Do not disassemble Kaneka thin-film 

silicon photovoltaic module(s) (hereinafter 

referred to as the MODULE(S)), as this 

may cause fire, electric shock, and injury.

 

Do not shock the MODULES (e.g. by 

stepping on it), as this may break the glass 

part and cause malfunction, electric shock 

and injury.

 

 

Follow the procedure in this manual when 

installing the MODULE and its platform.

 

Beware of electric shock and short-circuit, as 

the MODULE generates high-tension current 

when exposed to light.

 

 

 

Wear a safety belt, protection footwear, and 

protection gloves when installing the 

MODULE to prevent falling and electric 

shock. (Install safety fence and scaffolding 

to prevent falling.)

 

The platform, connection box, and the 

inverter (power conditioner) must be 

grounded based on the regulation about 

grounding method.

 

 

 

Do not expose the MODULE to the 

artificially concentrated sunlight.   

 

 

 

http://www.wholesalesolar.com/solar-panels.html

Summary of Contents for G-SA060

Page 1: ...060 002 KANEKA Thin Film PV Installation Manual MODULE TYPE G SA060 KANEKA CORPORATION 3 2 4 NAKANOSHIMA KITA KU OSAKA 530 8288 JAPAN reference No G SA060 002 http www wholesalesolar com solar panels...

Page 2: ...Follow the procedure in this manual when installing the MODULE and its platform Beware of electric shock and short circuit as the MODULE generates high tension current when exposed to light Wear a saf...

Page 3: ...G SA060 002 1 Dimensions http www wholesalesolar com solar panels html...

Page 4: ...Pmax Vpm V 67 0 Current at Pmax Ipm A 0 90 Tolerance 10 Max System Voltage V 530 Fire Rating Class C Dimension mm 990 2 5 x 960 2 5 Depth mm 40 1 0 Weight kg 13 7 REMARK 1 During initial 6 weeks of op...

Page 5: ...on UL Listed MODULES should be multiplied by a factor of 125 when determining component voltage ratings conductor capacities fuse sizes and size of controls connected to the MODULE output Refer to Art...

Page 6: ...Installation shall be in accordance with CSA 22 1 Safety Standard for Electrical Installations Canadian Electrical Code Part 1 All mounting hardware shall be stainless steel Method 1 Fix the MODULES t...

Page 7: ...the 2 cramps must be 660 950mm Optimize the tightness of the cramps with greatest care so that the MODULES will not come off and so that the cramps will not break the frames of the MODULES and or glas...

Page 8: ...s for interconnection between the MODULES during array assembly in the field As these connectors can only be assembled in the factory we recommend the use of commercially available output wiring produ...

Page 9: ...ew needs to provide sufficient torque to ensure that the lug is mechanically secure 4 Connect a minimum 10AWG solid conductor copper ground wire to the ground lug You will use stainless steel hardware...

Page 10: ...G SA060 002 7 Limitation See the Attachment A Instruction for using G type UL grade http www wholesalesolar com solar panels html...