background image

 

G-SA060-002

 

 

 

Recommended mounting system for installation method 2 is “Solar Mount 

/S-5! PV Clamp Sets” made by UniRac, Inc. Install the mounting system as 
instructed by a installation manual of the mounting system. (Refer to installation 
manual provided by UniRac.) Then, fix the MODULES with the cramps (4 pairs 
or more per module). The cramps should be fixed to the side frames of 
MODULES. Cramps A - B and C - D in the diagram below must be located 
symmetrically. The distance between the center of the 2 cramps must be 660 – 
950mm. 

 
 
 
 
 
 
 
 
 
 

 

Optimize the tightness of the cramps with greatest care so that the MODULES 

will not come off and so that the cramps will not break the frames of the 
MODULES and/or glasses. 

 
Handling Instruction to install a mounting system 

*Do not shock the MODULES (e.g. by stepping on it), as this may break the glass 

part and cause malfunction, electric shock and injury.   

*Wear a safety belt, protection footwear, and protection gloves when installing 

the MODULE to prevent falling and electric shock. 

*Beware of electric shock and short-circuit, as the MODULE generates high- 

tension current when exposed to light. 
 

660 - 950mm 

http://www.wholesalesolar.com/solar-panels.html

Summary of Contents for G-SA060

Page 1: ...060 002 KANEKA Thin Film PV Installation Manual MODULE TYPE G SA060 KANEKA CORPORATION 3 2 4 NAKANOSHIMA KITA KU OSAKA 530 8288 JAPAN reference No G SA060 002 http www wholesalesolar com solar panels...

Page 2: ...Follow the procedure in this manual when installing the MODULE and its platform Beware of electric shock and short circuit as the MODULE generates high tension current when exposed to light Wear a saf...

Page 3: ...G SA060 002 1 Dimensions http www wholesalesolar com solar panels html...

Page 4: ...Pmax Vpm V 67 0 Current at Pmax Ipm A 0 90 Tolerance 10 Max System Voltage V 530 Fire Rating Class C Dimension mm 990 2 5 x 960 2 5 Depth mm 40 1 0 Weight kg 13 7 REMARK 1 During initial 6 weeks of op...

Page 5: ...on UL Listed MODULES should be multiplied by a factor of 125 when determining component voltage ratings conductor capacities fuse sizes and size of controls connected to the MODULE output Refer to Art...

Page 6: ...Installation shall be in accordance with CSA 22 1 Safety Standard for Electrical Installations Canadian Electrical Code Part 1 All mounting hardware shall be stainless steel Method 1 Fix the MODULES t...

Page 7: ...the 2 cramps must be 660 950mm Optimize the tightness of the cramps with greatest care so that the MODULES will not come off and so that the cramps will not break the frames of the MODULES and or glas...

Page 8: ...s for interconnection between the MODULES during array assembly in the field As these connectors can only be assembled in the factory we recommend the use of commercially available output wiring produ...

Page 9: ...ew needs to provide sufficient torque to ensure that the lug is mechanically secure 4 Connect a minimum 10AWG solid conductor copper ground wire to the ground lug You will use stainless steel hardware...

Page 10: ...G SA060 002 7 Limitation See the Attachment A Instruction for using G type UL grade http www wholesalesolar com solar panels html...

Reviews: