background image

32

GB

On/Off

This function is used to switch the stove and the 
remote control on or off. Keep the key pressed for 
at least two seconds to switch the system on or 
off. Then press the key SEND.

You  can  use  the  two  keys  to  set  the  wished 
temperature  between  a  min.  value  of  7°C  and  a 
max. value of 40°C.

Please  join  the  following  procedure  to  set  the 
functioning mode:

Automatic Functioning

 

power 1 

(on1)

 

power 2  

(on2)

 

power 3  

(on3)

 

power 4  

(on4)

 

power 5 

(on5)

SEND

Use this key to transmit the selected information 
to the pcb.

ECONO

This  key  activates  or  deactivates  the  function 
ECONO.    Keep  the  key  pressed  for  at  least  two 
seconds to activate or deactivate this function.

TURBO

This  key  activates  or  deactivates  the  function 
TURBO.  Keep  the  key  pressed  for  at  least  two 
seconds to activate or deactivate this function.

CLOCK FUNCTION

Please join the following procedure to set the clock 
function on the remote control:
- press the symbol 

 and the time blinking.

-  use  the  keys 

 and 

  to  set  hour  and 

minutes.

- press 

 again to confirm and SEND to transmit 

the function to the pcb.

ON1

Using this key you can set a single time schedule for 
the automatic switching on of the stove (program 1).

OFF1

Using this key you can set a single time schedule 
for  the  automatic  switching  off  of  the  stove 
(program 1).

ON2

Using this key you can set a single time schedule 
for  the  automatic  switching  on  of  the  stove 
(program 2).

OFF2

Using this key you can set a single time schedule 
for  the  automatic  switching  off  of  the  stove 
(program 2).

AUTO

With  this  key  you  can  decide  to  repeat  the 
programmed switching on and off (program 1 and 
2) every day. The key AUTO activates this function. 
Keep the key pressed for at least two seconds to 
activate or deactivate this function.

CANCEL

Use  the  key  CANCEL  in  the  event  you  want  to 
cancel  some  programmed  switching  on  or  off  of 
the stove.

LCD 2

Keys and main functions

The remote control can be used 
to  check  the  stove.  The  remote 
control offers some functions 
which  are  not  available  from 
the  keyset,  like  the  automatic 
programming of the switching on 
and off of the unit.

How to use the remote control:
1.  Direct  the  remote  control  on 
the control board of the stove
2. Check there are no obstacles 
between the remote control and 
the receiver on the stove
3. Every function you set on the 
remote control must be confirmed 
pressing  the  key  SEND.  After 
selecting the wished function, an 
acoustic  signal  will  confirm  your 
choice.

Remote control (if any)

Summary of Contents for Mignon 6

Page 1: ...INSTALLER USER MANUAL For Petite 6 Air Stove...

Page 2: ...the stove door handle sides can reach high temperatures Therefore pay attention and use the proper precautions above all in the presence of children elderly or disabled persons and animals Assembly m...

Page 3: ...servance of the instruc tions contained herein We decline every responsibility derived from improper use of the stove from incorrect use by the user from un authorized modifications and or repairs fro...

Page 4: ...eaning and maintenance to be performed by the user should not be made by children without supervision Do not use the stove as a ladder or scaffold Do not put clothes to dry on the stove Any clothes ha...

Page 5: ...t not be less than 30 m3 The air must come in through permanent openings made in walls in proximity to the stove which give onto the outside with a minimum cross section area of 100 cm2 These openings...

Page 6: ...nless steel pipe must not be used At the bottom of the flue pipe provide an inspection cap to allow periodic checking and cleaning which must be done annually Make a gas tight connection to the flue p...

Page 7: ...different dimensions and forms according to the angle of inclination of the roof so it is necessary to adopt minimum heights The chimney cap must be a wind proof type and must be above the ridge Event...

Page 8: ...you will read the word Eco and the set temperature on the display 9 This led blinks every time the stove is loading pellets 10 This led is on only while the stove is lighting up in order to indicate...

Page 9: ...automatic switching on of the stove program 1 OFF1 Using this key you can set a single time schedule for the automatic switching off of the stove program 1 ON2 Using this key you can set a single time...

Page 10: ...fferent selections from the remote control the stove will restart working as it did before you activated the turbo function Keep the key TURBO 1 pressed for at least two seconds to activate this funct...

Page 11: ...n 20 minutes between the switching off and subsequent switching on of the stove In this way the unit will have time to arrange a complete cooling phase in the event this minimal interval is not calcul...

Page 12: ...reheating the resistor preceding lighting LOAD WOOD the stove is loading pellets On the control board the LED resistance is on FIRE ON The stove is in the flame stabilization phase flame present ON 1...

Page 13: ...Data Dis A DESCRIZIONE Modifica B C D E F G MZ ASSIEME 6KW ESTETICA MIGNON 41547 g 17 05 2016 Via delle Arti e dei Mestieri 1 3 H I Trattamento 4705001 v e R e c i d o C 1 5 770 487 32 431 25 174 158...

Page 14: ...e weight Kg 45 N Test Report K18532016T1 It is recommended that the control of emissions after installation The pellets are cylinders of compressed wood produced from sawdust and wood processing chips...

Page 15: ...erature the display will show MODULATION Stove start up We highly recommend to turn to our Authorized Service Centre for the installation and the first ignition of the device as it not only carries ou...

Page 16: ...cur also when there is not enough pellets flow to light up the unit Press the key On Off on the control board to reset the alarm Wait until the cooling phase is completed clean the brazier and start u...

Page 17: ...Cleaning the glass The glass is a self cleaning type therefore while the stove is working a veil of air is blown across its surface to remove ash and dirt nevertheless over a period of several hours...

Page 18: ...ar and below the stove Eventual deposits of dust or ash on the blades of the fan can cause an imbalance in the fans leading to noisy performance It is therefore necessary to clean the fans at least on...

Page 19: ...ollection compartment Cleaning ash tray Cleaning the door and glass Cleaning the interior heat exchanger smoke fan compartment Cleaning complete exchanger Clean T to exhaust Flue Door gasket ash Inter...

Page 20: ...body stove RESTART PELLET Reduction motor if the motor stops the thermostove continues to function until the flame goes out for lack of fuel and until It has cooled down to the minimum level Flue gas...

Page 21: ...pted 6 Card defective 1 Check that the power cord is connected 2 Use the switch back to operate it 3 Unplug the stove from the power outlet for about one minute and then turn on If the problem persist...

Page 22: ...se the drawer ashtray 10 Perform periodic cleaning 11 Check the operation of the extractor flue 12 Contact an authorized service center 13 Make sure the place of stowage pellet and re place it with a...

Page 23: ...xhaust fumes Contact your Authorized Service Center 7 Check the quality of the pellets Contact your Authorized Service Center 8 Increase the level in the parameters relating to the speed of the fan ex...

Page 24: ...oreign objects 7 Close the door or replace the gaskets with original 8 Change the type of pellet recommended by the manufacturer Sometimes depending on the type the stage of adjustment of the paramete...

Page 25: ...48 GB NOTES Cod 001124...

Reviews: