manualshive.com logo in svg
background image

853240D-1404i

•  Please read this entire manual before installation and use of 

this appliance. Failure to follow these instructions could result 

in property damage, bodily injury, or even death.

• 

Contact  your  local  building  or  fire  officials  about  obtaining 

permits, restrictions and installation inspection requirements in 

your area.

•  Save these instructions.

• 

If your heater is not properly installed, a house fire may result. 

For everyone’s safety, follow all Installation and Operating 

Directions. Never use makeshift compromises during the 

installation of this appliance. Contact your local building 

or  fire  officials  about  restrictions  and  installation  inspection 

requirements in your area. These Pellet Stove Room Heaters 

have been designed for use in the US and Canada and are 

suitable for mobile homes.

This unit is not intended to be used as a 

primary source of heat. 

Certified  to  ASTM  E  1509,  (R2017),  and 

Certified to ULC S627, 2000, and(UM) 84-HUD

U.S. Environmental Protection Agency 

Certified to comply with 2015 

particulate emissions standards.

United States Stove Company

227 Industrial Park Road

South Pittsburg, TN 37380

MODEL: AP60

Owner’s Operation and Instruction Manual

SAVE THESE INSTRUCTIONS

THIS MANUAL WILL HELP YOU TO OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM THE HEATER, AND ENABLE YOU 

TO ORDER REPAIR PARTS CORRECTLY. KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.

CALIFORNIA PROPOSITION 65 WARNING:

This product can expose you to chemicals including carbon monoxide, which 

is known to the State of California to cause cancer, birth defects and/or other 

reproductive harm. For more information, go to www.P65warnings.ca.gov

Ce produit peut vous exposer à des produits chimiques, y compris le 

monoxyde de carbone, qui est connu dans l'État de Californie pour causer 

le cancer, des malformations congénitales et / ou d'autres problèmes de 

reproduction. Pour plus d'informations, visitez www.P65warnings.ca.gov

0215PS086S

Содержание Ashley AP60

Страница 1: ...rce of heat Certified to ASTM E 1509 R2017 and CertifiedtoULCS627 2000 and UM 84 HUD U S Environmental Protection Agency Certified to comply with 2015 particulate emissions standards United States Sto...

Страница 2: ...pellets under these circumstances and a safety concern may arise from sparks or fumes entering the room Allow the stove to cool before performing any maintenance or cleaning Ashes must be disposed in...

Страница 3: ...ngth no greater than 1 5 not less than 8 200 BTU lb moisture under 8 by weight ash under 1 by weight and salt under 300 parts per million Pellets that are soft contain excessive amounts of loose sawdu...

Страница 4: ...o the installation clearances and restrictions Any reduction in clearance to combustibles may only be done by means approved by a regulatory authority INSTALL ALL VENTS AT CLEARANCES SPECIFIED BY THE...

Страница 5: ...4 B Side Wall To Flue 3 77 C Back wall To Appliance 2 51 D Back wall To Flue 3 77 E Wall To Corner Of Appliance 2 51 F Ceiling Height To Floor 60 1524 G Ceiling Height To Appliance 27 686 1 2 12 5mm o...

Страница 6: ...the use of Simpson Dura Vent or Metal Fab pipe if you use other pipe consult your local building codes and or building inspectors Do not use Type B Gas Vent pipe or galvanized pipe with this unit The...

Страница 7: ...an stated herein could cause bodily harm heater damage and void your warranty HORIZONTAL EXHAUST VENT INSTALLATION 1 Locate your pellet stove in a location which meets the requirements of this manual...

Страница 8: ...er than 3ft 0 91m to get above the snowdrift line This same installation can be used if your heater is below ground level by simply adding the clean out section and vertical pipe inside until ground l...

Страница 9: ...80 Part 24 Canadian installations require that the heater must be connected to a 3 or 4 inch factory built chimney conforming to CAN ULC S629 See the installation illustrations in this manual for mini...

Страница 10: ...te is the primary objective in effectively burning pellets of various brands and qualities in your stove The air to fuel ratio can be adjusted to allow almost any fuel quality to burn effectively by f...

Страница 11: ...t will not properly control the unit When adjusting the Draft Fan setting try only 1 setting above or below the heat setting It is better to leave the stove in the automatic mode ROOM FAN The room fan...

Страница 12: ...the preselected desired heat range setting 1 to 5 and the minimum heat range setting of 1 The T Stat will not turn the stove on and off When the desired room temperature has been reached and the T Sta...

Страница 13: ...t increase heat output but may seriously impair the stoves performance by generating considerable smoke Do not burn wet pellets The stove s performance depends heavily on the quality of your pellet fu...

Страница 14: ...To recognize an overheat situation in the stove and shut down the fuel feed or auger system B In case of a malfunctioning convection blower the high temperature thermodisc will automatically shut down...

Страница 15: ...n use A qualified chimney sweep can perform this service It is also recommended that before each heating season the entire system be professionally inspected cleaned and if necessary repaired To clean...

Страница 16: ...er and eight nuts and rope gasket using high temperature silicone to adhere the gasket to the door 6 Never use substitute materials for the glass DO NOT abuse the door glass by striking slamming or si...

Страница 17: ...e hopper Loss of draft pressure Make sure that the viewing door is closed and sealed properly If not adjust door catch and or replace door gaskets Check that all outside connections are clear of any o...

Страница 18: ...ve is in the Shut Down state waiting for the off button or for a 15 minute period after the stove was turned off or for the stove to cool down or for the door to be closed Flashing dash in Heat Range...

Страница 19: ...19 Wiring Diagram GRAY WHITE RED GREEN HIGH Located on the heat sheild below the hopper RED RED CORRECT WRONG Insure the wires are connected to the bottom two prongs of the hopper switch as shown...

Страница 20: ...20 Repair Parts 27 34 33 29 30 31 32 28 26 23 22 21 20 24 25 19 17 18 16 14 15 9 8 7 6 1 4 5 2 3 10 11 12 13...

Страница 21: ...18 893012 Auger 1 19 28846 Auger motor Bracket 1 20 80782 Combustion Blower 1 21 88308 Blower Gasket 1 22 86896 Ignitor Tube Weldment 1 23 80607 Ignitor 1 24 40867 Transition Blower 1 25 80781 Auger...

Страница 22: ...0 DIA X 1 00 2 6 892194 Bottom Glass Retainer 1 7 892195 Top Glass Retainer 1 8 893013 Door Glass 1 9 88082 Door Gasket 1 Repair Parts In order to maintain warranty components must be replaced using o...

Страница 23: ...07 Date _____________________ Engineer Name ________________________________ License No ____________________________________ Company _____________________________________ Telephone No _______________...

Страница 24: ...anuel dans un lieu s r pour toute consultation ult rieure Lorsque vous nous crivez donnez toujours le num ro de mod le complet qui se trouve sur la plaque signal tique fix e sur l appareil de chauffag...

Страница 25: ...__________________________ Service de 07 Date _____________________ Nom de l ing nieur ____________________________ N de licence _________________________________ Compagnie ___________________________...

Страница 26: ...sation de composants tiers annulera la garantie Cl Num ro d article La description Qt 1 893011 Manipuler 1 2 86895 Tige De Poign e 1 3 AC09185 Kit Bille Roulante 1 4 40868 Porte D alimentation 1 5 835...

Страница 27: ...e 1 11 610861 Assemblage De La Plaque Sup rieure 1 12 80491 Micro Interrupteur 1 13 891148 Poign e En Plastique 1 14 80834 Ventilateur De Convection 1 15 80480 Thermistance 1 16 28873 Couvercle De La...

Страница 28: ...21 Pi ces De Rechange 27 34 33 29 30 31 32 28 26 23 22 21 20 24 25 19 17 18 16 14 15 9 8 7 6 1 4 5 2 3 10 11 12 13...

Страница 29: ...ON NOIR BLANC ROUGE BLEU ORANGE PRISE MOLEX AU CIRCUIT IMPRIM PCB PRINCI PAL BLANC NOIR ROUGE BLANC BLANC SOUFFLANTE DE DISTRIBUTION VENTILATEUR D VACUATION THERMISTOR VERT HAUTE Situ sur le bouclier...

Страница 30: ...ux fois par seconde Cela indique que le po le fonctionne normalement et qu une condition de temp rature excessive existe provoquant l arr t du combustible Indicateur de r glage du niveau de chaleur He...

Страница 31: ...e V rifiez que le raccordement du pressostat au foyer ne contienne aucune cendre ni obstruction Le syst me vis sans fin est bloqu ou il y a une vo te de combustible dans la tr mie qui emp che le combu...

Страница 32: ...usement le pot de combustion et le foyer Il peut tre souhaitable de pulv riser l int rieur de la tr mie nettoy e avec un spray de silicone a rosol si votre po le est dans une zone tr s humide Le syst...

Страница 33: ...es par enfouissement dans le sol ou autrement dispers es localement elles doivent tre conserv es dans le r cipient ferm jusqu ce que toutes les braises aient t compl tement refroidies Le conteneur ne...

Страница 34: ...s du conduit de fum e Lorsqu elle est enflamm e la cr osote produit un feu extr mement chaud ce qui peut endommager la chemin e ou m me d truire la maison Malgr leur grande efficacit les po les granul...

Страница 35: ...WN Transformer votre r chaud est une question d appuyer sur la touche POWER sur le panneau d affichage La lumi re verte se rallume au rouge lorsque le bouton POWER est pouss Le moteur de la vis arr te...

Страница 36: ...des pastilles concass s ou l che qui ressemble de la sciure ou de sable Pellets peuvent tre cribl s avant d tre plac dans la tr mie pour liminer la plupart des amendes 2 Reliures Certains granul s so...

Страница 37: ...ionn de la plage de chaleur d sir e 1 5 et le r glage de la plage de chaleur minimale de 1 Le T Stat n allumera ni ne teindra le po le Lorsque la temp rature ambiante souhait e est atteinte et que le...

Страница 38: ...ustez le r glage du ventilateur de tirage essayez seulement 1 r glage au dessus ou en dessous du r glage de chaleur Il est pr f rable de laisser le po le en mode automatique VENTILATEUR DE LA PI CE Le...

Страница 39: ...on Votre po le est quip d un syst me d allumage automatique qui devra allumer le combustible dans un d lai de 5 10 minutes en appuyant sur le bouton ON Marche Quand les granul s entrent dans le pot de...

Страница 40: ...artie 24 Les installations au Canada n cessitent que le po le soit connect une chemin e d usine en 3 ou 4 pouces conform ment CAN ULC S629 Consultez les illustrations d installations dans ce manuel po...

Страница 41: ...r l installation voir Figure 7 Une patte de support doit tre plac juste sous le bouchon de terminaison ou un tous les 4 pieds 1 22 m pour rendre le syst me plus stable Si vous habitez dans une r gion...

Страница 42: ...stible est souhait e l installation doit tre conforme la norme CAN CSA B365 NE PAS OBTENIR COMBUSTION AIR DU GRENIER GARAGE OU TOUTE AUTRE AREA non a r es VOUS POUVEZ OBTENIR AIR DE COMBUSTION D UN VI...

Страница 43: ...s une vall e pouvant causer des conditions malsaines ou nuisibles PELLET TYPE D VENT Une liste UL de 3 pouces ou 4 pouces de type culot PL vent syst me d chappement doit tre utilis pour l installation...

Страница 44: ...ral pour la chemin e 3 77 C Arri re du mur Vers l appareil 2 51 D Mur du fond To Flue 3 77 E Mur au coin de l appareil 2 51 F Hauteur du plafond au sol 60 1524 G Hauteur du plafond par rapport l appa...

Страница 45: ...sibles D GAGEMENTS Votre po le granul s a t test et homologu pour une installation dans le secteur r sidentiel maison mobile et alc ve applications conform ment aux autorisations donn es Pour des rais...

Страница 46: ...tallation de l unit ou dans l espace requis pour le ravitaillement et le retrait des cendres Cela pourrait entra ner un incendie Ne pas surchauffer ou utiliser des combustibles volatiles ou combustibl...

Страница 47: ...a porte N essayez pas de faire fonctionner l unit avec une vitre cass e Une vitre de remplacement peut tre achet e chez votre revendeur U S Stove de chauffages pour pi ce carburant aux granul s N essa...

Страница 48: ...our tre utilis s aux USA et au Canada et conviennent pour des maisons mobiles U S Environmental Protection Agency Certifi aux normes d missions de 2020 particules United States Stove Company 227 Indus...