43
GB
Safety devices
Pressure switch:
monitors
depression in the smoke duct.
It is designed to shut down
the pellet feed screw in the
event of an obstructed flue or
significant back-pressure in
the presence of wind. At the
time of the pressure switch will
show “
A L A R - D E P - F A I L
”.
Pellets temperature safety:
In the rare event there is a too
high temperature in the tank,
the thermostat for pellets
safety with manual reset
creates an alarm “
A L A R - S I C -
F A I L
” stopping the pellet boiler
stove. You
need to reset the system
working on the device placed
on the back of the thermostove.
Room thermostat
: the room
thermostat detects the present
temperature in the room. When
it detects the set temperature
on the display, the stove will
go into operation in ECO ie
hold function to save fuel.
The
room
thermostat
should be spread so as not
to be conditioned by the
temperature of the body stove.
RESTART
PELLET
Reduction motor:
if the
motor stops, the thermostove
continues to function until the
flame goes out for lack of fuel,
and until It has cooled down to
the minimum level.
Flue gas temperature sensor:
thermocouple that measures
the temperature of the fumes
while keeping the operation or
shuts the thermostove when
the flue gas temperature drops
below the preset value.
Electrical
safety:
the
stove is protected against
violent surges of current (ex.
lightnings) by the main fuse
4 A which is located on the
control panel at the rear of the
thermostove. Other fuses to
protect the electronic boards
are to be found on the boards
themselves.
Tampering with the safety devices is prohibited.
It is only after eliminating the cause which gave
rise to the intervention of the safety system, that it is possible to relight the stove and thus reset
the automatic operation of the sensor. To understand which anomaly has occurred, consult this
manual at paragraph relating to alarms which explains what to do based on the alarm message the
stove display.