Alarm signals
Regular checks should be carried out by the user, who
should only contact the Authorized Assistance Center
if no solution is found.
In the event of a working defect, the system informs the user about the type of failure occurred.
The following table summarises the alarms, kind of problem and possible solution:
1. Lighting button
2. Fuse F4AL250V
3. Thermostat reset button
4. Environmental probe
4
3
1
2
"COOL FIRE"
: in the event of an even
very short lack of current, the stove
switches off. As soon as the power
supply is back, the stove will start a
cooling cycle and the display will show
the words “Cool fire”. After completing
the cooling cycle, the stove will start up
again.
NOTE: If your stove is supplied with
a remote control and there is a lack
of current, remember to program the
eventual switching on and off times
again. In the event of a lack of current,
the stove will loose any previous time
settings.
Once the power supply is back, press
the key SEND on the remote control to
retransmit the automatic programming
you previously set to the stove.
"SERv"
: the signal “Serv” on the display
means that the stove has reached
1200 hours working. Please contact an
authorised technical service to arrange a
supplementary maintenance.
"ALARM NO ACC"
: this alarm occurs
when the time foreseen for a light up
(around 15 minutes) passes and the
smokes temperature is still too low. This
can occur also when there is not enough
pellets flow to light up the unit. Press the
key On/Off on the control board to reset
the alarm. Wait until the cooling phase
is completed, clean the brazier and start
up with a new switching on.
"ALARM NO FIRE"
: this alarm occurs in
the event the stove switches off during
its working phase (for example if there is
no pellets left in the pellets tank).
Press the key On/Off on the control
board to reset the alarm. Wait until the
cooling phase is completed, clean the
brazier and start up with a new switching
on.
"ALARM FAN FAIL"
: this alarm occurs
in the event the smokes ejector is broken
or the pcb cannot detect the speed of
the smokes exhaust fan.
In this case press the key On/Off to reset
the alarm and contact the technical
assistance.
"ALARM SOND FUMI"
: this alarm
occurs in the event the sensor for smokes
temperature is broken or not connected.
You will read the words Alarm Son fumi
on the display. In this case press the key
On/Off to reset the alarm and contact
the technical assistance.
"ALARM DEP SIC FAIL"
: this alarm is
signalised by the Leds ALF and ALC
blinking on the control board.
It indicates two different possibilities:
an obstruction in the flue or a possible
overheating of the stove. In both cases
the motor reducer to load the endless
screw stops working and the stove
switches off. Press the key On/Off to
reset the alarm. Check the possible
activation of the manual reset thermostat
on the back of the stove (4). Unscrew the
safety cap and press the key.
In the event you have the same problem
more than once, please contact the
technical assistance.